Simultaneous Analysis of Monovalent Anions and Cations with a Sub-Microliter Dead-Volume Flow-Through Potentiometric Detector for Ion Chromatography.

A microliter dead-volume flow-through cell as a potentiometric detector is described in this article for sensitive, selective and simultaneous detection of common monovalent anions and cations in single column ion chromatography for the first time. The detection cell consisted of less selective anion- and cation-selective composite membrane electrodes together with a solid-state composite matrix reference electrode. The simultaneous separation and sensitive detection of sodium (Na(+)), potassium (K(+)), ammonium (NH4 (+)), chloride (Cl(-)) and nitrate (NO3 (-)) in a single run was achieved by using 98% 1.5 mM MgSO4 and 2% acetonitrile eluent with a mixed-bed ion-exchange separation column without suppressor column system. The separation and simultaneous detection of the anions and cations were completed in 6 min at the eluent flow-rate of 0.8 mL/min. Detection limits, at S/N = 3, were ranged from 0.2 to 1.0 µM for the anions and 0.3 to 3.0 µM for the cations, respectively. The developed method was successfully applied to the simultaneous determination of monovalent anions and cations in several environmental and biological samples.

[1]  M. S. Franco,et al.  Evolution in miniaturized column liquid chromatography instrumentation and applications: An overview. , 2015, Journal of chromatography. A.

[2]  P. Haddad,et al.  Capillary ion chromatography with on-column focusing for ultra-trace analysis of methanesulfonate and inorganic anions in limited volume Antarctic ice core samples. , 2015, Journal of chromatography. A.

[3]  M. Zhang,et al.  Admittance detector for high impedance systems: design and applications. , 2014, Analytical chemistry.

[4]  G. Desmet,et al.  Design and performance evaluation of a microfluidic ion-suppression module for anion-exchange chromatography. , 2014, Journal of chromatography. A.

[5]  J. Namieśnik,et al.  A solid phase extraction-ion chromatography with conductivity detection procedure for determining cationic surfactants in surface water samples. , 2013, Talanta.

[6]  Xavier Cetó,et al.  Development and application of an electronic tongue for detection and monitoring of nitrate, nitrite and ammonium levels in waters , 2013 .

[7]  Hong Yu,et al.  Separation and determination of pyrrolidinium ionic liquid cations by ion chromatography with direct conductivity detection , 2013 .

[8]  Yan Zhu,et al.  Determination of low-level anions in seawater by ion chromatography with cycling-column-switching. , 2012, Journal of chromatography. A.

[9]  Yan Zhu,et al.  A novel ion chromatography cycling-column-switching system for the determination of low-level chlorate and nitrite in high salt matrices. , 2012, Journal of hazardous materials.

[10]  W. Xu,et al.  Fabrication of electrolytic cell for online post-column electrochemical derivatization in ion chromatography. , 2012, Analytica chimica acta.

[11]  Lijun He,et al.  Effective indirect enrichment and determination of nitrite ion in water and biological samples using ionic liquid-dispersive liquid-liquid microextraction combined with high-performance liquid chromatography. , 2011, Journal of chromatography. A.

[12]  A. Ivaska,et al.  Simultaneous monitoring of the transport of anions and cations across polypyrrole based composite membranes , 2011 .

[13]  O. Isildak Determination of inorganic anions in mushrooms by ion chromatography with potentiometric detection , 2009 .

[14]  C. Crafts,et al.  Evaluation of methods for the simultaneous analysis of cations and anions using HPLC with charged aerosol detection and a zwitterionic stationary phase. , 2009, Journal of chromatographic science.

[15]  Y. Ishihara,et al.  Simultaneous Determination of Anions and Cations in Sewage Water by Ion Chromatography with Dual-Flow Path System , 2009 .

[16]  P. Stepnowski,et al.  Simultaneous Determination of Ionic Liquid Cations and Anions Using Ion Chromatography with Tandem Ion Exchange Columns: a Preliminary Assessment , 2008, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[17]  Yücel Şahin,et al.  Ion chromatography-potentiometric detection of inorganic anions and cations using polypyrrole and overoxidized polypyrrole electrode , 2008 .

[18]  T. Takeuchi,et al.  Determination of common inorganic anions and cations by non-suppressed ion chromatography with column switching. , 2008, Journal of chromatography. A.

[19]  M. Severi,et al.  An improved flow analysis-ion chromatography method for determination of cationic and anionic species at trace levels in Antarctic ice cores. , 2007, Analytica chimica acta.

[20]  P. Haddad,et al.  Ion chromatography on a latex-coated silica monolith column. , 2007, Journal of chromatography. A.

[21]  T. Takeuchi,et al.  Tunable separation of anions and cations by column switching in ion chromatography. , 2007, Talanta.

[22]  P. Niedzielski,et al.  A new tool for inorganic nitrogen speciation study: simultaneous determination of ammonium ion, nitrite and nitrate by ion chromatography with post-column ammonium derivatization by Nessler reagent and diode-array detection in rain water samples. , 2006, Analytica chimica acta.

[23]  Yan Zhu,et al.  Suppressed anion chromatography using mixed zwitter-ionic and carbonate eluents. , 2006, Journal of chromatography. A.

[24]  M. Zenki,et al.  Anion chromatography using on-line recycled eluents. , 2005, Journal of chromatography. A.

[25]  M. Andaç,et al.  Application of a New pH-Sensitive Electrode as a Detector in Flow Injection Potentiometry , 2005 .

[26]  P. Haddad,et al.  High-speed simultaneous ion-exclusion/cation-exchange chromatography of anions and cations on a weakly acidic cation-exchange resin column. , 2003, Journal of chromatography. A.

[27]  Jiye Jin,et al.  Simultaneous separation of inorganic anions and cations by using anion-exchange and cation-exchange columns connected in tandem in ion chromatography. , 2003, Journal of chromatography. A.

[28]  A. Apelblat Dissociation constants and limiting conductances of organic acids in water , 2002 .

[29]  M. Pietraszkiewicz,et al.  Potentiometric detection of organic acids in liquid chromatography using polymeric liquid membrane electrodes incorporating macrocyclic hexaamines. , 2001, Journal of chromatography. A.

[30]  H. Nam,et al.  Ion chromatography detector based on solid-state ion-selective electrode array. , 2000, Journal of chromatography. A.

[31]  R. Schasfoort,et al.  An ISFET-based anion sensor for the potentiometric detection of organic acids in liquid chromatography , 2000 .

[32]  A. Asan,et al.  Simultaneous detection of monovalent anions and cations using all solid-state contact PVC membrane anion and cation-selective electrodes as detectors in single column ion chromatography. , 1999, Talanta.

[33]  A. Covington,et al.  Ion‐selective electrode potentiometric detection in ion‐chromatography , 1993 .

[34]  M. Trojanowicz Potentiometric Detection in High-Performance Ion-Chromatography , 1990 .

[35]  A. E. Greenberg,et al.  Standard methods for the examination of water and wastewater : supplement to the sixteenth edition , 1988 .

[36]  E. Arnold,et al.  Standard methods for the examination of water and wastewater. 16th ed. , 1985 .

[37]  Koji Suzuki,et al.  Determination of monovalent cations by ion chromatography with ion-selective electrode detection , 1983 .

[38]  W. C. Bauman,et al.  Novel ion exchange chromatographic method using conductimetric detection , 1975 .

[39]  A. Marks,et al.  Salivary Sodium‐Potassium Ratio and Plasma Renin Activity in Hypertension , 1969, Circulation.

[40]  A. White,et al.  Physiological and pharmacological regulation of human salivary electrolyte concentrations; with a discussion of electrolyte concentrations of some other exocrine secretions. , 1955, The Journal of clinical investigation.