In vitro cardiac catheter navigation via augmented reality surgical guidance

Catheter-driven cardiac interventions have emerged in response to the need of reducing invasiveness associated with the traditional cut-and-sew techniques. Catheter manipulation is traditionally performed under real-time fluoroscopy imaging, resulting in an overall trade-off of procedure invasiveness for radiation exposure of both the patient and clinical staff. Our approach to reducing and potentially eliminating the use of flouroscopy in the operating room entails the use of multi-modality imaging and magnetic tracking technologies, wrapped together into an augmented reality environment for enhanced intra-procedure visualization and guidance. Here we performed an in vitro study in which a catheter was guided to specific targets located on the endocardial atrial surface of a beating heart phantom. "Therapy delivery" was modeled in the context of a blinded procedure, mimicking a beating heart, intracardiac intervention. The users navigated the tip of a magnetically tracked Freezor 5 CRYOCATH catheter to the specified targets. Procedure accuracy was determined as the distance between the tracked catheter tip and the tracked surgical target at the time of contact, and it was assessed under three different guidance modalities: endoscopic, augmented reality, and ultrasound image guidance. The overall RMS targeting accuracy achieved under augmented reality guidance averaged to 1.1 mm. This guidance modality shows significant improvements in both procedure accuracy and duration over ultrasound image guidance alone, while maintianing an overall targeting accuracy comparable to that achieved under endoscopic guidance.

[1]  Terry M. Peters,et al.  A Statistical Model for Point-Based Target Registration Error With Anisotropic Fiducial Localizer Error , 2008, IEEE Transactions on Medical Imaging.

[2]  Douglas L. Jones,et al.  Inside the beating heart: an in vivo feasibility study on fusing pre- and intra-operative imaging for minimally invasive therapy , 2009, International Journal of Computer Assisted Radiology and Surgery.

[3]  Terry M. Peters,et al.  Ultrasound Probe Tracking for Real-Time Ultrasound/MRI Overlay and Visualization of Brain Shift , 1999, MICCAI.

[4]  Terry M. Peters,et al.  Validation of four-dimensional ultrasound for targeting in minimally-invasive beating-heart surgery , 2009, Medical Imaging.

[5]  Douglas L. Jones,et al.  2D Ultrasound Augmented by Virtual Tools for Guidance of Interventional Procedures , 2007, MMVR.

[6]  Douglas L. Jones,et al.  An augmented reality environment for image-guidance of off-pump mitral valve implantation , 2007, SPIE Medical Imaging.

[7]  Terry M. Peters,et al.  Towards Subject-Specific Models of the Dynamic Heart for Image-Guided Mitral Valve Surgery , 2007, MICCAI.

[8]  Andrew D. Wiles,et al.  Virtual reality-enhanced ultrasound guidance: A novel technique for intracardiac interventions , 2008, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[9]  Douglas L. Jones,et al.  From pre-operative cardiac modeling to intra-operative virtual environments for surgical guidance: an in vivo study , 2008, SPIE Medical Imaging.

[10]  Gerhard Hindricks,et al.  Specific linear left atrial lesions in atrial fibrillation: intraoperative radiofrequency ablation using minimally invasive surgical techniques. , 2002, Journal of the American College of Cardiology.

[11]  D. Hill,et al.  Cardiac catheterisation guided by MRI in children and adults with congenital heart disease , 2003, The Lancet.

[12]  T. Peters,et al.  On Enhancing Planning and Navigation of Beating-Heart Mitral Valve Surgery Using Pre-operative Cardiac Models , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  P. Yock,et al.  Radiofrequency catheter ablation guided by intracardiac echocardiography. , 1994, Circulation.

[14]  H Calkins,et al.  Visualization and temporal/spatial characterization of cardiac radiofrequency ablation lesions using magnetic resonance imaging. , 2000, Circulation.

[15]  Terry M. Peters,et al.  Virtual Reality-Enhanced Ultrasound Guidance for Atrial Ablation: In vitroEpicardial Study , 2008, MICCAI.

[16]  Terry M. Peters,et al.  Improved Statistical TRE Model When Using a Reference Frame , 2007, MICCAI.

[17]  Douglas L. Jones,et al.  Dynamic Cardiac Mapping on Patient-Specific Cardiac Models , 2008, MICCAI.

[18]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[19]  S A Ben-Haim Catheter Navigation in Modern Electrophysiology , 2000, Journal of cardiovascular electrophysiology.