Radiometric performance evaluation of ASTER VNIR, SWIR, and TIR

Radiometric performance of the Advanced Spectrometer for Thermal Emission and Reflection Radiometer (ASTER) is characterized by using acquired imagery data. Noise-equivalent reflectance and temperature, sensitivity (gain), bias (offset), and modulation transfer function (MTF) are determined for the visible and near-infrared (VNIR), the shortwave infrared (SWIR), and the thermal infrared (TIR) radiometers that constitute ASTER. The responsivity evaluated from onboard calibration (OBC) and from instrumented scenes show similar trends for the VNIR: the OBC data yield 2.7% to 5.5% a year for the VNIR. The SWIR response changed less than 2% in the 3.5 years following launch. The zero-radiance offsets of most VNIR and SWIR bands have increased about 1/2 digital number per year. The in-orbit noise levels, calculated by the standard deviation of dark (VNIR and SWIR) or ocean (TIR) scenes, show that all bands are within specification. The MTF at Nyquist and 1/2 Nyquist frequencies was determined for all bands using the Moon (VNIR and SWIR) or terrestrial scenes with lines of sharp thermal contrast. In-orbit performance along-track and cross-track is better than prelaunch for the VNIR and SWIR bands in nearly all cases; the TIR effectively meets specification in-orbit.

[1]  K. Arai Preliminary assessment of radiometric accuracies for MOS-1 sensors , 1988 .

[2]  C. McClain,et al.  Changes in the Radiometric sensitivity of SeaWiFS determined from lunar and solar-based measurements. , 1999, Applied optics.

[3]  Hideyuki Tonooka,et al.  ASTER/TIR onboard calibration status and user-based recalibration , 2004, SPIE Remote Sensing.

[4]  M. Leroy,et al.  Selection and characterization of Saharan and Arabian desert sites for the calibration of optical satellite sensors , 1996 .

[5]  Brian L. Markham,et al.  Landsat-7 mission and early results , 1999, Remote Sensing.

[6]  Mark A. Folkman,et al.  Updated results from performance characterization and calibration of the TRWIS III hyperspectral imager , 1997, Optics & Photonics.

[7]  Stuart F. Biggar,et al.  Review of SPOT-1 and -2 calibrations at White Sands from launch to the present , 1993, Defense, Security, and Sensing.

[8]  Kohei Arai,et al.  Inflight test site cross calibration between mission instruments onboard the same platform , 1997 .

[9]  Paul Soule,et al.  POLDER multiangular calibration using desert sites: method and performances , 1997, Remote Sensing.

[10]  Simon J. Hook,et al.  Vicarious calibration of ASTER thermal infrared bands , 2005, IEEE Transactions on Geoscience and Remote Sensing.

[11]  Yasushi Yamaguchi,et al.  Scientific basis of ASTER instrument design , 1993, Defense, Security, and Sensing.

[12]  Kohei Arai,et al.  ASTER preflight and inflight calibration and the validation of Level 2 products , 1998, IEEE Trans. Geosci. Remote. Sens..

[13]  Akira Iwasaki,et al.  Improvement of ASTER/SWIR crosstalk correction , 2004, SPIE Remote Sensing.

[14]  Kohei Arai,et al.  Preflight and in-flight calibration plan for ASTER , 1996 .

[15]  Kris J. Becker,et al.  Radiometric calibration of spacecraft using small lunar images , 1999, Remote Sensing.

[16]  Akira Iwasaki,et al.  Enhancement of spectral separation performance for ASTER/SWIR , 2002, SPIE Optics + Photonics.

[17]  William H. Farrand,et al.  In-flight radiometric calibration of HYDICE using a reflectance-based approach , 1996, Optics + Photonics.

[18]  Hiroyuki Fujisada Overview of ASTER instrument on EOS-AM1 platform , 1994, Optics & Photonics.

[19]  Xavier Briottet,et al.  Results of POLDER in-flight calibration , 1999, IEEE Trans. Geosci. Remote. Sens..