Development and testing of a compact endoscope manipulator for minimally invasive surgery.

Objective: This report describes the design, development, and testing of a novel compact surgical assistant robot to control the orientation and insertion depth of a laparoscopic endoscope during minimally invasive abdominal surgery. In contrast to typical endoscope manipulators, the described robot is particularly compact and lightweight, is simple to set up and use, occupies no floor or operating table space, and does not limit access to the patient in any way.Materials and Methods: The sterilizable endoscope manipulator is sufficiently small and lightweight at 625 g and 110 mm in diameter that it can be placed directly on the abdomen of the patient without interfering with other handheld instruments during minimally invasive surgery. It consists of an annular base, a clamp to hold an endoscope trocar, and two joints which enable azimuth rotation and inclination of the endoscope about a pivot point at the incision. The endoscope insertion depth is controlled by a cable winding acting against a compressi...

[1]  Jocelyne Troccaz,et al.  FROM THE LABORATORY TO THE OPERATING ROOM: USABILITY TESTING OF LER, THE LIGHT ENDOSCOPE ROBOT , 2004 .

[2]  A W Partin,et al.  Comparison of robotic versus human laparoscopic camera control . , 1995, The Journal of urology.

[3]  Philippe Cinquin,et al.  A compact, compliant laparoscopic endoscope manipulator , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[4]  P C McAfee,et al.  Robotic arm enhancement to accommodate improved efficiency and decreased resource utilization in complex minimally invasive surgical procedures. , 1996, Studies in health technology and informatics.

[5]  Finlay Robotic controlled endoscopic manipulator , 1996 .

[6]  G. Buess,et al.  A new remote-controlled endoscope positioning system for endoscopic solo surgery , 2000, Surgical Endoscopy.

[7]  K Masamune,et al.  A new safe laparoscopic manipulator system with a five-bar linkage mechanism and an optical zoom. , 1999, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[8]  P. Finlay,et al.  Controlled trial of the introduction of a robotic camera assistant (Endo Assist) for laparoscopic cholecystectomy , 2002, Surgical Endoscopy And Other Interventional Techniques.

[9]  J. Dankelman,et al.  Peroperative analysis of the surgical procedure , 2001, Surgical Endoscopy And Other Interventional Techniques.

[10]  L. Mettler,et al.  One year of experience working with the aid of a robotic assistant (the voice-controlled optic holder AESOP) in gynaecological endoscopic surgery. , 1998, Human reproduction.

[11]  John Kenneth Salisbury,et al.  The Intuitive/sup TM/ telesurgery system: overview and application , 2000, Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065).

[12]  Philippe Cinquin,et al.  LER: the light endoscope robot , 2003, Proceedings 2003 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2003) (Cat. No.03CH37453).

[13]  Russell H. Taylor,et al.  A telerobotic assistant for laparoscopic surgery , 1995 .

[14]  Garth H Ballantyne,et al.  Comparison of Laparoscopic Colectomy With and Without the Aid of a Robotic Camera Holder , 2002, Surgical laparoscopy, endoscopy & percutaneous techniques.

[15]  V. L. Nickel,et al.  DEVELOPMENT OF USEFUL FUNCTION IN THE SEVERELY PARALYZED HAND. , 1963, The Journal of bone and joint surgery. American volume.

[16]  J. Dankelman,et al.  Time-action analysis of instrument positioners in laparoscopic cholecystectomy , 2001, Surgical Endoscopy And Other Interventional Techniques.

[17]  Philippe Cinquin,et al.  Development of a Compact Cable-Driven Laparoscopic Endoscope Manipulator , 2002, MICCAI.