Spin‐echo MRI using π/2 and π hyperbolic secant pulses

Frequency‐modulated (FM) pulses have practical advantages for spin‐echo experiments, such as the ability to produce a broadband π rotation, with an inhomogeneous radiofrequency (RF) field. However, such use leads to a nonlinear phase of the transverse magnetization, which is why FM pulses like the hyperbolic secant (HS) pulse are not commonly used for multislice spin‐echo magnetic resonance imaging (MRI). Here, a general theory and methods are described for conventional spin‐echo imaging using a π HS pulse for refocusing. Phase profiles produced by the HS pulse are analytically described. The analysis is extended to yield the specific relationships between pulse parameters and gradients, which must be satisfied to compensate the nonlinear phase variation produced with a spin‐echo sequence composed of π/2 and π HS pulses (the π/2 HS − π HS sequence). The latter offers advantages for multislice spin‐echo MRI, including excellent slice‐selection and partial compensation for RF inhomogeneity. Furthermore, it can be implemented with a shorter echo time and lower power deposition than a previously described method using a pair of π HS pulses. Magn Reson Med 61:175–187, 2009. © 2008 Wiley‐Liss, Inc.

[1]  Yu-Chung N. Cheng,et al.  Susceptibility weighted imaging (SWI) , 2004, Zeitschrift fur medizinische Physik.

[2]  M. Garwood,et al.  Broadband adiabatic refocusing without phase distortion. , 1997, Journal of magnetic resonance.

[3]  Geoffrey Bodenhausen,et al.  Refocusing with chirped pulses for broadband excitation without phase dispersion , 1989 .

[4]  Andrew A. Maudsley,et al.  Dynamic range improvement in NMR imaging using phase scrambling , 1988 .

[5]  M. S. Silver,et al.  Highly selective {π}/{2} and π pulse generation , 1984 .

[6]  Hoult,et al.  Selective spin inversion in nuclear magnetic resonance and coherent optics through an exact solution of the Bloch-Riccati equation. , 1985, Physical review. A, General physics.

[7]  K Shmueli,et al.  Slice-Selective Spin-Echo Formation Using Hyperbolic Secant RF Pulses , 2003 .

[8]  D Kunz,et al.  Use of frequency‐modulated radiofrequency pulses in MR imaging experiments , 1986, Magnetic resonance in medicine.

[9]  Michael Garwood,et al.  Symmetric pulses to induce arbitrary flip angles with compensation for rf inhomogeneity and resonance offsets , 1991 .

[10]  C. Jack,et al.  Adiabatic inner volume selection (IVS) method for high resolution 3D MRI , 2003 .

[11]  A. J. Shaka,et al.  Adjustable, broadband, selective excitation with uniform phase. , 2002, Journal of magnetic resonance.

[12]  E. Wu,et al.  Phase‐Scrambled RF Excitation for 3D Volume‐Selective Multislice NMR Imaging , 1992, Magnetic resonance in medicine.

[13]  A Macovski,et al.  A reduced power selective adiabatic spin‐echo pulse sequence , 1991, Magnetic resonance in medicine.

[14]  Geoffrey Bodenhausen,et al.  Suppression of artifacts in two-dimensional J spectroscopy , 1977 .

[15]  Jullie W Pan,et al.  High frequency volume coils for clinical NMR imaging and spectroscopy , 1994, Magnetic resonance in medicine.

[16]  Alan R. Rath,et al.  Amplitude- and frequency/phase-modulated refocusing pulses that induce plane rotations even in the presence of inhomogeneous B1 fields , 1988 .

[17]  L DelaBarre,et al.  The return of the frequency sweep: designing adiabatic pulses for contemporary NMR. , 2001, Journal of magnetic resonance.

[18]  D Kunz,et al.  Frequency‐modulated radiofrequency pulses in spin‐echo and stimulated‐echo experiments , 1987, Magnetic resonance in medicine.

[19]  Single‐shot, B1‐insensitive slice selection with a gradient‐modulated adiabatic pulse, BISS‐8 , 1996, Magnetic resonance in medicine.

[20]  Michael Garwood,et al.  Improved gradient‐echo 3D magnetic resonance imaging using pseudo‐echoes created by frequency‐swept pulses , 2006, Magnetic resonance in medicine.

[21]  Laura I Sacolick,et al.  Adiabatic refocusing pulses for volume selection in magnetic resonance spectroscopic imaging , 2007, Magnetic resonance in medicine.

[22]  D. Hoult,et al.  Selective population inversion in NMR , 1984, Nature.

[23]  Albert Macovski,et al.  A selective adiabatic spin-echo pulse , 1989 .

[24]  K. Uğurbil,et al.  Spectroscopic imaging with volume selection by unpaired adiabatic pi pulses: theory and application. , 2007, Journal of magnetic resonance.

[25]  Michael Garwood,et al.  In vivo visualization of Alzheimer's amyloid plaques by magnetic resonance imaging in transgenic mice without a contrast agent , 2004, Magnetic resonance in medicine.