Wireless Prototype Based on Pressure and Bending Sensors for Measuring Gate Quality

This paper presents a technological solution based on sensors controlled remotely in order to monitor, track and evaluate the gait quality in people with or without associated pathology. Special hardware simulating a shoe was developed, which consists of three pressure sensors, two bending sensors, an Arduino mini and a Bluetooth module. The obtained signals are digitally processed, calculating the standard deviation and establishing thresholds obtained empirically. A group of users was chosen with the aim of executing two modalities: natural walking and dragging the left foot. The gait was parameterized with the following variables: as far as pressure sensors are concerned, one pressure sensor under the first metatarsal (right sensor), another one under the fifth metatarsal (left) and a third one under the heel were placed. With respect to bending sensors, one bending sensor was placed for the ankle movement and another one for the foot sole. The obtained results show a rate accuracy oscillating between 85% (right sensor) and 100% (heel and bending sensors). Therefore, the developed prototype is able to differentiate between healthy gait and pathological gait, and it will be used as the base of a more complex and integral technological solution, which is being developed currently.

[1]  J. Delisa Gait analysis in the science of rehabilitation , 1998 .

[2]  Joseph A. Paradiso,et al.  A wireless modular sensor architecture and its application in on-shoe gait analysis , 2003, Proceedings of IEEE Sensors 2003 (IEEE Cat. No.03CH37498).

[3]  Joseph A. Paradiso,et al.  Gait Analysis Using a Shoe-Integrated Wireless Sensor System , 2008, IEEE Transactions on Information Technology in Biomedicine.

[4]  Bruce Williams,et al.  Clinical Gait Evaluation of the Athlete , 2010 .

[5]  Huiru Zheng,et al.  Assessing accelerometer based gait features to support gait analysis for people with complex regional pain syndrome , 2010, PETRA '10.

[6]  Ta-Te Lin,et al.  A wearable walking monitoring system for gait analysis , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  E. Tolosa,et al.  Comparative analysis of gait in Parkinson's disease, cerebellar ataxia and subcortical arteriosclerotic encephalopathy. , 1999, Brain : a journal of neurology.

[8]  M. Dinger,et al.  Comparisons of accelerometer and pedometer determined steps in free living samples. , 2011, Journal of physical activity & health.

[9]  M. Tomizuka,et al.  A mobile gait monitoring system for abnormal gait diagnosis and rehabilitation: a pilot study for Parkinson disease patients. , 2011, Journal of biomechanical engineering.

[10]  H. S. Wolff,et al.  iRun: Horizontal and Vertical Shape of a Region-Based Graph Compression , 2022, Sensors.

[11]  Fany Chedevergne Baropodomètre écologique : développement d'un chausson à semelle instrumentée pour l'analyse de la marche , 2008 .

[12]  Rezaul K. Begg,et al.  Foot Plantar Pressure Measurement System: A Review , 2012, Sensors.

[13]  Annegret Mündermann,et al.  Objective assessment of motor fatigue in multiple sclerosis using kinematic gait analysis: a pilot study , 2011, Journal of NeuroEngineering and Rehabilitation.

[14]  Qiao Li,et al.  In-Shoe Plantar Pressure Measurement and Analysis System Based on Fabric Pressure Sensing Array , 2010, IEEE Transactions on Information Technology in Biomedicine.

[15]  Stacy J. Morris,et al.  A shoe-integrated sensor system for wireless gait analysis and real-time therapeutic feedback , 2004 .

[16]  A. Achiron,et al.  Gait analysis in multiple sclerosis: characterization of temporal-spatial parameters using GAITRite functional ambulation system. , 2009, Gait & posture.

[17]  Yeh-Liang Hsu,et al.  A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring , 2010, Sensors.

[18]  Peter Ahrendt,et al.  A Novel Method for Measuring In-Shoe Navicular Drop during Gait , 2012, Sensors.

[19]  F. Naghdy,et al.  Evaluation of human gait through observing body movements , 2008, 2008 International Conference on Intelligent Sensors, Sensor Networks and Information Processing.

[20]  Yan Liu,et al.  Design and Test of a Soft Plantar Force Measurement System for Gait Detection , 2012, Sensors.

[21]  Tao Liu,et al.  Gait Analysis Using Wearable Sensors , 2012, Sensors.

[22]  María Teresa Arredondo,et al.  Gait assessment in Parkinson's disease patients through a network of wearable accelerometers in unsupervised environments , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[23]  M.R. Popovic,et al.  A reliable gait phase detection system , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[24]  E. Boyko,et al.  Reliability of F-Scan In-Shoe Measurements of Plantar Pressure , 1998, Foot & ankle international.

[25]  Neil Zhao Full-Featured Pedometer Design Realized with 3-Axis Digital Accelerometer , 2010 .

[26]  Christopher Kirtley,et al.  Clinical Gait Analysis: Theory and Practice , 2006 .

[27]  S. Reingold,et al.  The Multiple Sclerosis Functional Composite measure (MSFC): an integrated approach to MS clinical outcome assessment , 1999, Multiple sclerosis.

[28]  G. Gehlsen,et al.  Gait characteristics in multiple sclerosis: progressive changes and effects of exercise on parameters. , 1986, Archives of physical medicine and rehabilitation.