Microfluidic chip with microweir structure for continuous sample separating and collecting applications

Abstract We aim to establish a microfluidic chip device capable for continuous sample separation by integrating a simple and easy-fabrication microweir structure for crossflow filtration in the present study. The proposed microchip device is composed of two major components, including flow channels and microweir structure. Using the injection of the mixed samples with different sizes, the samples can be transported through the flow channel and then be separated by the microweir structure. The microweir structure with a different height can be generated by utilizing a standard lithography and overetching process, so that the gap can be used to be a selective tool to separate the smaller sample. In this study, a 10-μm gap was generated by established a microweir structure with 20 μm in height with a 20-minute etching process. Optimal sample separation efficiency in 82% can be obtained of the sample concentration in 10 3  μL −1 by utilizing the proposed design of the microweir structure to separate two groups of beads in different diameters. In conclusion, the proposed chip device can be regarded as an effective tool for clinical application.

[1]  Y. Tai,et al.  Micromachined membrane particle filters , 1999 .

[2]  Pierre Aimar,et al.  Modelling of filtration: from the polarised layer to deposit formation and compaction , 2002 .

[3]  Mehmet Toner,et al.  A microfabrication-based dynamic array cytometer. , 2002, Analytical chemistry.

[4]  A. Kim,et al.  Cake Structure in Dead-End Membrane Filtration: Monte Carlo Simulations , 2002 .

[5]  H Morgan,et al.  Measurement of Bacterial Flagellar Thrust by Negative Dielectrophoresis , 1999, Biotechnology progress.

[6]  Mark M. Clark,et al.  Modeling of flux decline during crossflow ultrafiltration of colloidal suspensions , 1998 .

[7]  R. Pethig,et al.  Separation of viable and non-viable yeast using dielectrophoresis. , 1994, Journal of biotechnology.

[8]  Galip Akay,et al.  Crossflow microfiltration of low concentration-nonliving yeast suspensions , 2004 .

[9]  B. Andersen,et al.  Single-step separation of red blood cells. Granulocytes and mononuclear leukocytes on discontinuous density gradients of Ficoll-Hypaque. , 1974, Journal of immunological methods.

[10]  Chien-Hsiung Tsai,et al.  A high‐discernment microflow cytometer with microweir structure , 2008, Electrophoresis.

[11]  Robert H. Davis,et al.  Microfiltration of protein mixtures and the effects of yeast on membrane fouling , 1999 .

[12]  Elinore M Mercer,et al.  Microfluidic sorting of mammalian cells by optical force switching , 2005, Nature Biotechnology.

[13]  Mann A. Shoffner,et al.  Integrated cell isolation and polymerase chain reaction analysis using silicon microfilter chambers. , 1998, Analytical biochemistry.

[14]  Andreas Radbruch,et al.  High gradient magnetic cell separation with MACS. , 1990, Cytometry.

[15]  Andreas Manz,et al.  On-chip free-flow magnetophoresis: continuous flow separation of magnetic particles and agglomerates. , 2004, Analytical chemistry.

[16]  J. Kutter,et al.  Integrating advanced functionality in a microfabricated high-throughput fluorescent-activated cell sorter. , 2003, Lab on a chip.