COMPARISON OF TWO DIFFERENT TYPES OF LIF:MG,CU,P THERMOLUMINESCENT DOSIMETERS FOR DETECTION OF BETA RAYS (BETA-TLDS) FROM 90SR/90Y, 85KR AND 147PM SOURCES

Targeted radionuclide therapies in nuclear medicine departments increasingly depend on using unsealed beta radiation sources in the labeling of peptides and antibodies. Monitoring doses received by the fingers and hands during these procedures is best accomplished with TLD dosimeters that can be located at the fingertips. The present study examines the response of two TLD dosimeters (MCP-Ns and GR200A) to 90Sr/90Y, 85Kr, and 147Pm. The dosimeters were supplied by two different services, and all irradiations were performed at the PTB Institute in Germany. Each dosimetry service evaluated the dosimeters without knowledge that they had been purposefully irradiated. The accuracy and precision of the dosimeters were evaluated as a function of delivered dose, energy of beta particles and angular incidence. The results are compared to performance measures recommended by the IEC. Both dosimeter types displayed significant energy dependence. Angular dependence was moderate. Accuracy and precision as a function of dose (linearity) differed between the two systems, with the MCP-Ns being noticeably better than the GR200A. The superior precision makes the MCP-Ns much more useful for extremity dose measurements. The differences between these two dosimeter systems reinforce the need to evaluate a dosimeter carefully before using it in the daily work routine.

[1]  Eric C Frey,et al.  Comparison of organ residence time estimation methods for radioimmunotherapy dosimetry and treatment planning--patient studies. , 2009, Medical physics.

[2]  D. Salvo,et al.  Radiation protection in 90Y-labelled DOTA-D-Phe1-Tyr3-octreotide preparations , 2009, Nuclear medicine communications.

[3]  Giovanni Borasi,et al.  Radiation protection in Y-labelled DOTA-D-Phe1-Tyr-octreotide preparations , 2009 .

[4]  Sophie Lancelot,et al.  Exposure of medical personnel to radiation during radionuclide therapy practices , 2008, Nuclear medicine communications.

[5]  E. Glatstein Radiation protection in radionuclide therapies with 90Y-conjugates: risks and safety , 2008 .

[6]  F. Forrer,et al.  Diagnostic versus therapeutic doses of [(177)Lu-DOTA-Tyr(3)]-octreotate: uptake and dosimetry in somatostatin receptor-positive tumors and normal organs. , 2007, Cancer biotherapy & radiopharmaceuticals.

[7]  F. Vanhavere,et al.  Personal dose monitoring in hospitals: global assessment, critical applications and future needs. , 2007, Radiation protection dosimetry.

[8]  C. Furetta,et al.  Comparison of the TL responses of two different preparations of LiF:Mg,Cu,P irradiated by photons of various energies. , 2007, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[9]  P. Ambrosi,et al.  Quality assurance of personal beta particle dosemeters used for individual monitoring of occupationally exposed persons. , 2006, Radiation protection dosimetry.

[10]  A. Rimpler,et al.  Beta radiation exposure of medical staff and implications for extremity dose monitoring. , 2006, Radiation protection dosimetry.

[11]  M. Duch,et al.  Comparison of two extremity dosemeters based on LiF:Mg,Cu,P thin detectors for mixed beta-gamma fields. , 2006, Radiation protection dosimetry.

[12]  F. Forrer,et al.  Treatment with 177Lu-DOTATOC of patients with relapse of neuroendocrine tumors after treatment with 90Y-DOTATOC. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[13]  T. Davidson,et al.  Measurements of finger doses in x-ray guided surgery, nuclear medicine and research. , 2005, Radiation protection dosimetry.

[14]  D. Delacroix,et al.  Radionuclide and Radiation Protection Data Handbook (2002) (2nd Edition, 2002): Special Issue: Radiation Protection Dosimetry , 2003 .

[15]  J. Guerre,et al.  RADIONUCLIDE AND RADIATION PROTECTION DATA HANDBOOK 2002 , 2002 .

[16]  P. Ambrosi,et al.  Intercomparison measurements of extremity dosemeters in beta and/or photon radiation fields. , 2001, Radiation protection dosimetry.

[17]  P. Ambrosi,et al.  Harmonisation and dosimetric quality assurance in individual monitoring for external radiation. , 2001, Radiation protection dosimetry.

[18]  J. Azorín,et al.  Thermoluminescent response of LiF : Mg,Cu,P+PTFE prepared in Mexico to 90Sr/90Y beta particles , 2001 .

[19]  R. Chawla,et al.  Characterisation of MCP-7s- material for use as a beta extremity dosemeter , 2000 .

[20]  G. Dietze,et al.  Editorial - Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation , 2000 .

[21]  M. Moscovitch Personnel Dosimetry Using LiF:Mg,Cu,P , 1999 .

[22]  T. Niewiadomski 25 Years of TL Dosimetry at the Institute of Nuclear Physics, Kraków , 1996 .

[23]  P. Olko,et al.  Ultra-thin LiF:Mg,Cu,P detectors for beta dosimetry , 1995 .

[24]  P. Ambrosi,et al.  Mandatory Type Tests of Solid State Dosimetry Systems as an Appropriate Aid to Quality Assurance in Individual Monitoring , 1990 .