Abstract Glass systems and facades are widely used in building structures, due to a multitude of aspects. Beside these motivations, from a pure structural point of view, glazing envelopes represent one of the most critical components for multi-storey buildings under the action of exceptional loads as impacts, explosions, seismic events or hazards in general. Such systems represent in fact the first line of defense from outside. Given the current lack of specific design regulations for the mitigation and enhancement of glass curtains under extreme loads, as well as the typically brittle behaviour and limited tensile resistance of glass as material for constructions, the same facades require specific, fail-safe design concepts. In this paper, the feasibility and potential of special mechanical connectors interposed at the interface between a multi-storey primary building structure and the enclosing glazing facade are investigated via accurate Finite-Element (FE) numerical models, under various impact scenarios. At the current stage of research, careful consideration is given both to the observed global performances as well as to local mechanisms, based on computationally efficient FE models inclusive of damage models to account for failure mechanisms in each system component. Compared to earlier research efforts, the attention is focused on the multi-hazard performance of a given case study building, subjected to extreme loadings such as seismic loads or blast events. As shown, even the typically different features of the examined loading conditions, when the proposed vibration control devices are properly designed and the curtain wall is considered as part of a full 3D building, the final result is an overall assembled structural system in which the glazing facade can work as a passive control system for the building system, in the form of a distributed Tuned-Mass Damper (TMD), with marked benefits in terms of protection level as well as design optimization.

[1]  Daniel S. Stutts,et al.  Analysis of Damage in Laminated Architectural Glazing Subjected to Wind Loading and Windborne Debris Impact , 2013 .

[2]  Paul A. Kremer,et al.  Dynamic Racking Performance of an Earthquake-Isolated Curtain Wall System , 2000 .

[3]  Richard A. Behr,et al.  Seismic Performance of Architectural Glass in a Storefront Wall System , 1995 .

[4]  Claudio Amadio,et al.  Exploratory numerical analysis of two-way straight cable-net façades subjected to air blast loads , 2014 .

[5]  Mauro Overend,et al.  Diagnostic Interpretation of Glass Failure , 2007 .

[6]  Dipti Ranjan Sahoo,et al.  Seismic rehabilitation of damaged reinforced concrete frames using combined metallic yielding passive devices , 2017 .

[7]  Iunio Iervolino,et al.  REXEL: computer aided record selection for code-based seismic structural analysis , 2010 .

[8]  Gangbing Song,et al.  Vibration Control of a Pipeline Structure Using Pounding Tuned Mass Damper , 2016 .

[9]  Claudio Amadio,et al.  Elastoplastic dissipative devices for the mitigation of blast resisting cable-supported glazing façades , 2012 .

[10]  R. S. Matthews,et al.  Investigation of dynamic water penetration tests for curtain walling , 1996 .

[11]  Claudio Amadio,et al.  Passive Control Systems for the Blast Enhancement of Glazing Curtain Walls Under Explosive Loads , 2017 .

[12]  Jan Belis,et al.  Guidance for European structural design of glass components: support to the implementation, harmonization and further development of the Eurocodes , 2014 .

[13]  Giuseppe Carlo Marano,et al.  Multi-objective optimization of a dissipative connection for seismic protection of wall-frame structures , 2016 .

[14]  Hong Hao,et al.  Laboratory test and numerical simulation of laminated glass window vulnerability to debris impact , 2013 .

[15]  S. W. Park Analytical modeling of viscoelastic dampers for structural and vibration control , 2001 .

[16]  Abdolreza Joghataie,et al.  Designing optimal tuned mass dampers for nonlinear frames by distributed genetic algorithms , 2012 .

[17]  Sun Sook Kim,et al.  The Effects of the Frame Ratio and Glass on the Thermal Performance of a Curtain Wall System , 2015 .

[18]  Claudio Amadio,et al.  Optimal design of tuned mass dampers for a multi‐storey cross laminated timber building against seismic loads , 2016 .

[19]  Gianluca Nestovito,et al.  Implementation of smart-passive dampers combined with double concave friction pendulum devices to retrofit an existing highway viaduct exploiting the seismic early warning information , 2016 .

[20]  Maurizio Froli,et al.  A Contribution to the Theoretical Prediction of Life-Time in Glass Structures , 2010 .

[21]  Yozo Fujino,et al.  Optimal tuned mass damper for seismic applications and practical design formulas , 2008 .

[22]  Chris P. Pantelides,et al.  Development of a loading history for seismic testing of architectural glass in a shop-front wall system , 1996 .

[23]  Lizhong Wang,et al.  An analytical solution for pre-crack behaviour of laminated glass under blast loading , 2016 .

[24]  Guido De Roeck,et al.  Robust design of a TMD for the vibration serviceability of a footbridge , 2016 .

[25]  Hong Hao,et al.  Parametric study of laminated glass window response to blast loads , 2013 .

[26]  Nobuyoshi Yamaguchi,et al.  Development of a passive damper device with high damping rubber for wooden houses , 2011 .

[27]  Chiara Bedon,et al.  Design of blast-loaded glazing windows and facades: a review of essential requirements towards standardization , 2016 .

[28]  Yen-Po Wang,et al.  Optimal design theories and applications of tuned mass dampers , 2006 .

[29]  Luís Simões da Silva,et al.  Design of Steel Structures: Eurocode 3: Design of Steel Structures, Part 1-1: General Rules and Rules for Buildings , 2010 .

[30]  Claudio Amadio,et al.  Viscoelastic spider connectors for the mitigation of cable-supported façades subjected to air blast loading , 2012 .

[31]  G. B. Warburton,et al.  Optimum absorber parameters for minimizing vibration response , 1981 .

[32]  Aslihan Tavil,et al.  Full-scale performance testing and evaluation of unitized curtain walls , 2015 .

[33]  Chiara Bedon,et al.  Low velocity impact performance investigation on square hollow glass columns via full-scale experiments and Finite Element analyses , 2017 .

[34]  Samuel L. Manzello,et al.  An Experimental Determination of a Real Fire Performance of a Non-Load Bearing Glass Wall Assembly , 2007 .

[35]  Farshid Fathi,et al.  Hybrid Coupled Building Control for similar adjacent buildings , 2017 .

[36]  Kyoung Sun Moon,et al.  Vertically distributed multiple tuned mass dampers in tall buildings: performance analysis and preliminary design , 2009 .

[37]  William T. Holmes,et al.  The 1997 NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures , 2000 .

[38]  R. S. Jangid,et al.  Vibration control of bridge subjected to multi-axle vehicle using multiple tuned mass friction dampers , 2016 .

[39]  L. F. Costa-Neves,et al.  Multimode vibration control of building steel-concrete composite floors submitted to human rhythmic activities , 2016 .

[40]  Young-Kyu Ju,et al.  Numerical and experimental analysis of combined behavior of shear-type friction damper and non-uniform strip damper for multi-level seismic protection , 2016 .

[41]  Kyoung Sun Moon Integrated damping systems for tall buildings: tuned mass damper/double skin facade damping interaction system , 2016 .

[42]  Richard A. Behr Architectural glass to resist seismic and extreme climatic events , 2009 .

[43]  Klára Machalická,et al.  The behaviour of Fire Resistant glass under fire , 2016 .

[44]  Chiara Bedon,et al.  Assessing the structural behaviour of square hollow glass columns subjected to combined compressive and impact loads via full-scale experiments , 2017 .

[45]  Claudio Amadio,et al.  Numerical and analytical investigation on the dynamic buckling behavior of glass columns under blast , 2014 .

[46]  Takuya Mizukami,et al.  THERMAL PERFORMANCE OF GLASS CURTAIN WALLS WITH THERMAL BREAK FRAMING SYSTEM , 2013 .

[47]  Mauro Overend,et al.  Thermal Healing of Realistic Flaws in Glass , 2016 .

[48]  Nirav Shah,et al.  The vulnerability of residential window glass to lightweight windborne debris , 2010 .

[49]  J. Dear,et al.  On the blast resistance of laminated glass , 2012 .

[50]  Chi-Chang Lin,et al.  Vibration suppression for high-speed railway bridges using tuned mass dampers , 2003 .

[51]  Z. Q. Chen,et al.  Control of Human-Induced Vibrations of a Curved Cable-Stayed Bridge: Design, Implementation, and Field Validation , 2016 .

[52]  C. V. Girija Vallabhan,et al.  Behaviour of window glass panels during earthquakes , 1997 .