Effect of Lumbar Lordosis on the Adjacent Segment in Transforaminal Lumbar Interbody Fusion: A Finite Element Analysis.

OBJECTIVE We used a finite element (FE) analysis to investigate the biomechanical changes caused by transforaminal lumbar interbody fusion (TLIF) at the L4-L5 level by lumbar lordosis (LL) degree. METHODS A lumbar FE model (L1-S5) was constructed based on computed tomography scans of a 30-year-old healthy male volunteer (pelvic incidence,= 50°; LL, 52°). We investigated the influence of LL on the biomechanical behavior of the lumbar spine after TLIF in L4-L5 fusion models with 57°, 52°, 47°, and 40° LL. The LL was defined as the angle between the superior end plate of L1 and the superior end plate of S1. A 150-N vertical axial preload was imposed on the superior surface of L3. A 10-N/m moment was simultaneously applied on the L3 superior surface along the radial direction to simulate the 4 basic physiologic motions of flexion, extension, lateral bending, and torsion in the numeric simulations. The range of motion (ROM) and intradiscal pressure (IDP) of L3-L4 were evaluated and compared in the simulated cases. RESULTS In all motion patterns, the ROM and IDP were both increased after TLIF. In addition, the decrease in lordosis generally increased the ROM and IDP in all motion patterns. CONCLUSIONS This FE analysis indicated that decreased spinal lordosis may evoke overstress of the adjacent segment and increase the risk of the pathologic development of adjacent segment degeneration; thus, adjacent segment degeneration should be considered when planning a spinal fusion procedure.

[1]  Jin-Sung Kim,et al.  Adjacent Segment Degeneration After Lumbar Interbody Fusion With Percutaneous Pedicle Screw Fixation for Adult Low-Grade Isthmic Spondylolisthesis: Minimum 3 Years of Follow-up , 2010, Neurosurgery.

[2]  H. Matsuzaki,et al.  Risk Factors of Adjacent Segment Disease After Transforaminal Inter-Body Fusion for Degenerative Lumbar Disease , 2017, Spine.

[3]  Hong Cheng,et al.  Prevalence of Adjacent Segment Degeneration After Spine Surgery: A Systematic Review and Meta-analysis , 2013, Spine.

[4]  Kyoung-Tak Kang,et al.  The influence of facet joint orientation and tropism on the stress at the adjacent segment after lumbar fusion surgery: a biomechanical analysis. , 2015, The spine journal : official journal of the North American Spine Society.

[5]  Shih-Hao Chen,et al.  Biomechanical comparison between lumbar disc arthroplasty and fusion. , 2009, Medical engineering & physics.

[6]  G. Andersson,et al.  Influence of single-level lumbar degenerative disc disease on the behavior of the adjacent segments--a finite element model study. , 2009, Journal of biomechanics.

[7]  Yongjung Kim,et al.  Adjacent Segment Disease FollowingLumbar/Thoracolumbar Fusion With Pedicle Screw Instrumentation: A Minimum 5-Year Follow-up , 2007, Spine.

[8]  Zhi-Hong Wu,et al.  Finite element analysis in adjacent segment degeneration after lumbar fusion , 2011, The international journal of medical robotics + computer assisted surgery : MRCAS.

[9]  Hsuan-Teh Hu,et al.  Biomechanical analysis of the lumbar spine on facet joint force and intradiscal pressure - a finite element study , 2010, BMC musculoskeletal disorders.

[10]  T M Keaveny,et al.  Nonlinear behavior of trabecular bone at small strains. , 2001, Journal of biomechanical engineering.

[11]  Jung-Hee Lee,et al.  Biomechanical changes of the lumbar segment after total disc replacement : charite(r), prodisc(r) and maverick(r) using finite element model study. , 2010, Journal of Korean Neurosurgical Society.

[12]  J. Pélissier,et al.  Sagittal alignment of spine and pelvis regulated by pelvic incidence: standard values and prediction of lordosis , 2006, European Spine Journal.

[13]  W. Lo,et al.  Stress analysis of the disc adjacent to interbody fusion in lumbar spine. , 2001, Medical engineering & physics.

[14]  Paul Park,et al.  Adjacent Segment Disease after Lumbar or Lumbosacral Fusion: Review of the Literature , 2004, Spine.

[15]  Vijay K. Goel,et al.  Biomechanical Rationale for Using Polyetheretherketone (PEEK) Spacers for Lumbar Interbody Fusion–A Finite Element Study , 2006, Spine.

[16]  C. Shim,et al.  Adjacent Segment Disease After Interbody Fusion and Pedicle Screw Fixations for Isolated L4–L5 Spondylolisthesis: A Minimum Five-Year Follow-up , 2010, Spine.

[17]  P. Korovessis,et al.  Effect of Sagittal Spinal Balance, Levels of Posterior Instrumentation, and Length of Follow-up on Low Back Pain in Patients Undergoing Posterior Decompression and Instrumented Fusion for Degenerative Lumbar Spine Disease: A Multifactorial Analysis , 2010, Spine.

[18]  B. Moran,et al.  An Anisotropic Hyperelastic Constitutive Model With Fiber-Matrix Shear Interaction for the Human Annulus Fibrosus , 2006 .

[19]  J. Snedeker,et al.  Pelvic incidence–lumbar lordosis mismatch results in increased segmental joint loads in the unfused and fused lumbar spine , 2014, European Spine Journal.

[20]  W. Hayes,et al.  Direct and computed tomography thickness measurements of the human, lumbar vertebral shell and endplate. , 1994, Bone.

[21]  V K Goel,et al.  Cancellous bone Young's modulus variation within the vertebral body of a ligamentous lumbar spine--application of bone adaptive remodeling concepts. , 1995, Journal of biomechanical engineering.

[22]  M. Hahn,et al.  The Thickness of Human Vertebral Cortical Bone and its Changes in Aging and Osteoporosis: A Histomorphometric Analysis of the Complete Spinal Column from Thirty‐Seven Autopsy Specimens , 1997, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[23]  G. Bergmann,et al.  Estimation of muscle forces in the lumbar spine during upper-body inclination. , 2001, Clinical biomechanics.

[24]  Na-xin Fu,et al.  Sagittal Alignment as Predictor of Adjacent Segment Disease After Lumbar Transforaminal Interbody Fusion. , 2017, World neurosurgery.

[25]  M M Panjabi,et al.  Three-Dimensional Movements of the Whole Lumbar Spine and Lumbosacral Joint , 1989, Spine.

[26]  John R. Johnson,et al.  Sagittal alignment as a risk factor for adjacent level degeneration: a case-control study. , 2008, Orthopedics.

[27]  D. Rothenfluh,et al.  Pelvic incidence-lumbar lordosis mismatch predisposes to adjacent segment disease after lumbar spinal fusion , 2015, European Spine Journal.