Verification of step-and-shoot IMRT delivery using a fast video-based electronic portal imaging device.

We present an investigation into the use of a fast video-based electronic portal-imaging device (EPID) to study intensity modulated radiation therapy (IMRT) delivery. The aim of this study is to test the feasibility of using an EPID system to independently measure the orchestration of collimator leaf motion and beam fluence; simultaneously measuring both the delivered field fluence and shape as it exits the accelerator head during IMRT delivery. A fast EPID that consists of a terbium-doped gadolinium oxysulphide (GdO2S:Tb) scintillator coupled with an inexpensive commercial 30 frames-per-second (FPS) CCD-video recorder (16.7 ms shutter time) was employed for imaging IMRT delivery. The measurements were performed on a Varian 2100 C/D linear accelerator equipped with a 120-leaf multileaf-collimator (MLC). A characterization of the EPID was performed that included measurements of spatial resolution, linac pulse-rate dependence, linear output response, signal uniformity, and imaging artifacts. The average pixel intensity for fields imaged with the EPID was found to be linear in the delivered monitor units of static non-IMRT fields between 3x3 and 15x15 cm2. A systematic increase of the average pixel intensity was observed with increasing field size, leading to a maximum variation of 8%. Deliveries of a clinical step-and-shoot mode leaf sequence were imaged at 600 MU/min. Measurements from this IMRT delivery were compared with experimentally validated MLC controller log files and were found to agree to within 5%. An analysis of the EPID image data allowed identification of three types of errors: (1) 5 out of 35 segments were undelivered; (2) redistributing all of the delivered segment MUs; and (3) leaf movement during segment delivery. Measurements with the EPID at lower dose rates showed poor agreement with log files due to an aliasing artifact. The study was extended to use a high-speed camera (1-1000 FPS and 10 micros shutter time) with our EPID to image the same delivery to demonstrate the feasibility of imaging without aliasing artifacts. High-speed imaging was shown to be a promising direction toward validating IMRT deliveries with reasonable image resolution and noise.

[1]  Benedick A Fraass,et al.  Incorporation of realistic delivery limitations into dynamic MLC treatment delivery. , 2002, Medical physics.

[2]  C. Ramsey,et al.  Leaf position error during conformal dynamic arc and intensity modulated arc treatments. , 2001, Medical physics.

[3]  M Partridge,et al.  IMRT verification with a camera-based electronic portal imaging system. , 2000, Physics in medicine and biology.

[4]  O Dössel,et al.  Monte Carlo simulations of the imaging performance of metal plate/phosphor screens used in radiotherapy. , 1999, Medical physics.

[5]  James F Dempsey,et al.  Validation of dynamic MLC-controller log files using a two-dimensional diode array. , 2003, Medical physics.

[6]  Ping Xia,et al.  Communication and sampling rate limitations in IMRT delivery with a dynamic multileaf collimator system. , 2002, Medical physics.

[7]  Accurate measurement of the dynamic response of a scanning electronic portal imaging device. , 2001, Medical physics.

[8]  Gary A. Ezzell,et al.  The overshoot phenomenon in step‐and‐shoot IMRT delivery , 2001, Journal of applied clinical medical physics.

[9]  M Partridge,et al.  Linear accelerator output variations and their consequences for megavoltage imaging. , 1998, Medical physics.

[10]  J. Stroom,et al.  Physical characteristics of a commercial electronic portal imaging device. , 1996, Medical physics.

[11]  Jean M. Moran,et al.  Verification of dynamic and segmental IMRT delivery by dynamic log file analysis , 2002, Journal of applied clinical medical physics.

[12]  S. Webb,et al.  Rapid portal imaging with a high-efficiency, large field-of-view detector. , 1998, Medical physics.

[13]  Sjirk N. Boon,et al.  Fast 2D phantom dosimetry for scanning proton beams. , 1998, Medical physics.

[14]  A G Glendinning,et al.  Measurement of the response of Gd2O2S:Tb phosphor to 6 MV x-rays , 2001, Physics in medicine and biology.

[15]  C. Ling,et al.  Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy. , 1998, Medical physics.

[16]  Optical scattering in camera-based electronic portal imaging. , 1999, Physics in medicine and biology.

[17]  Ben J.M. Heijmen,et al.  Dosimetric verification of intensity modulated beams produced with dynamic multileaf collimation using an electronic portal imaging device. , 1999 .

[18]  J. V. van Santvoort,et al.  Leaf trajectory calculation for dynamic multileaf collimation to realize optimized fluence profiles. , 1998, Physics in medicine and biology.

[19]  M C Kirby,et al.  Verification of dynamic multileaf collimation using an electronic portal imaging device. , 2000, Physics in medicine and biology.

[20]  P. Munro,et al.  X-ray quantum limited portal imaging using amorphous silicon flat-panel arrays. , 1998, Medical Physics (Lancaster).

[21]  A G Visser,et al.  Accurate portal dose measurement with a fluoroscopic electronic portal imaging device (EPID) for open and wedged beams and dynamic multileaf collimation. , 1998, Physics in medicine and biology.

[22]  L Kumaraswamy,et al.  Automatic verification of step-and-shoot IMRT field segments using portal imaging. , 2003, Medical physics.

[23]  A L Boyer,et al.  Quality assurance for dynamic multileaf collimator modulated fields using a fast beam imaging system. , 1997, Medical physics.

[24]  S Shalev,et al.  Output stability of a linear accelerator during the first three seconds. , 1996, Medical physics.

[25]  T LoSasso,et al.  Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode. , 2001, Medical physics.

[26]  M Partridge,et al.  Independent verification using portal imaging of intensity-modulated beam delivery by the dynamic MLC technique. , 1998, Medical physics.

[27]  E B Podgorsak,et al.  Verification of segmented beam delivery using a commercial electronic portal imaging device. , 1999, Medical physics.

[28]  G T Chen,et al.  Intensity modulated radiotherapy dose delivery error from radiation field offset inaccuracy. , 2000, Medical physics.

[29]  M van Herk,et al.  Leaf position verification during dynamic beam delivery: a comparison of three applications using electronic portal imaging. , 2000, Medical physics.