A quantitative, non-interferometric X-ray phase contrast imaging technique.

We present a quantitative, non-interferometric, X-ray differential phase contrast imaging technique based on the edge illumination principle. We derive a novel phase retrieval algorithm which requires only two images to be acquired and verify the technique experimentally using synchrotron radiation. The technique is useful for planar imaging but is expected to be important for quantitative phase tomography also. The properties and limitations of the technique are studied in detail.

[1]  Alessandro Olivo,et al.  Source size and temporal coherence requirements of coded aperture type x-ray phase contrast imaging systems. , 2010, Optics express.

[2]  P. C. Diemoz,et al.  Absorption, refraction and scattering in analyzer-based imaging: comparison of different algorithms. , 2010, Optics express.

[3]  E. Pisano,et al.  Diffraction enhanced x-ray imaging. , 1997, Physics in medicine and biology.

[4]  T. Gureyev,et al.  Phase retrieval using coherent imaging systems with linear transfer functions , 2004 .

[5]  S. Wilkins,et al.  Phase-contrast imaging using polychromatic hard X-rays , 1996, Nature.

[6]  Ziyu Wu,et al.  Low-dose, simple, and fast grating-based X-ray phase-contrast imaging , 2010, Proceedings of the National Academy of Sciences.

[7]  Atsushi Momose,et al.  Demonstration of X-Ray Talbot Interferometry , 2003 .

[8]  Alessandro Olivo,et al.  Phase and absorption retrieval using incoherent X-ray sources , 2012, Proceedings of the National Academy of Sciences.

[9]  Lucia Mancini,et al.  Medical applications of synchrotron radiation at the SYRMEP beamline of ELETTRA , 2005 .

[10]  K. Nugent,et al.  Quantitative Phase Imaging Using Hard X Rays. , 1996, Physical review letters.

[11]  Franz Pfeiffer,et al.  X-ray phase imaging with a grating interferometer. , 2005, Optics express.

[12]  R. Speller,et al.  A coded-aperture technique allowing x-ray phase contrast imaging with conventional sources , 2007 .

[13]  Alessandro Olivo,et al.  The relationship between wave and geometrical optics models of coded aperture type x-ray phase contrast imaging systems. , 2010, Optics express.

[14]  P. Cloetens,et al.  Phase objects in synchrotron radiation hard x-ray imaging , 1996 .

[15]  A. Snigirev,et al.  On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation , 1995 .

[16]  Timur E. Gureyev,et al.  Quantitative diffraction-enhanced x-ray imaging of weak objects , 2004 .

[17]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[18]  P. Cloetens,et al.  Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays , 1999 .

[19]  Z. Sharp,et al.  Atmospheric CO2 concentrations during ancient greenhouse climates were similar to those predicted for A.D. 2100 , 2009, Proceedings of the National Academy of Sciences.

[20]  Timur E. Gureyev,et al.  Refracting Röntgen’s rays: Propagation-based x-ray phase contrast for biomedical imaging , 2009 .

[21]  S. Wilkins,et al.  Linear algorithms for phase retrieval in the Fresnel region , 2004 .

[22]  Kentaro Uesugi,et al.  X-ray phase, absorption and scatter retrieval using two or more phase contrast images. , 2010, Optics express.

[23]  U. Bonse,et al.  AN X‐RAY INTERFEROMETER , 1965 .

[24]  Alberto Bravin,et al.  Digital mammography with synchrotron radiation , 1995 .

[25]  Keith A. Nugent,et al.  The measurement of phase through the propagation of intensity: an introduction , 2011 .

[26]  S. Wilkins,et al.  Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object , 2002, Journal of microscopy.

[27]  A Olivo,et al.  Image formation principles in coded-aperture based x-ray phase contrast imaging , 2008, Physics in medicine and biology.

[28]  F. Arfelli,et al.  Mammography imaging studies using a Laue crystal analyzer , 1996 .

[29]  Robert D. Speller,et al.  A non-free-space propagation x-ray phase contrast imaging method sensitive to phase effects in two directions simultaneously , 2009 .

[30]  S. Wilkins,et al.  Linear algorithms for phase retrieval in the Fresnel region. 2. Partially coherent illumination , 2006 .

[31]  A. W. Lohmann,et al.  An interferometer based on the Talbot effect , 1971 .

[32]  F Arfelli,et al.  An innovative digital imaging set-up allowing a low-dose approach to phase contrast applications in the medical field. , 2001, Medical physics.

[33]  S. Wilkins,et al.  Hard x-ray quantitative non-interferometric phase-contrast microscopy , 1999 .

[34]  Li Zhang,et al.  Alternative method for differential phase-contrast imaging with weakly coherent hard x rays , 2009 .

[35]  K. Creath V Phase-Measurement Interferometry Techniques , 1988 .

[36]  E. Vallazza,et al.  Development of a fast read-out system of a single photon counting detector for mammography with synchrotron radiation , 2011 .

[37]  E. Vallazza,et al.  A single-photon counting “edge-on” silicon detector for synchrotron radiation mammography , 2009 .

[38]  D. Vine,et al.  Analyzer-based phase contrast imaging and phase retrieval using a rotating anode x-ray source , 2007 .

[39]  Atsushi Momose,et al.  Demonstration of phase-contrast X-ray computed tomography using an X-ray interferometer , 1995 .

[40]  A Olivo,et al.  Modelling of a novel x-ray phase contrast imaging technique based on coded apertures , 2007, Physics in medicine and biology.

[41]  S. Wilkins,et al.  Phase-contrast imaging of weakly absorbing materials using hard X-rays , 1995, Nature.

[42]  B. L. Henke,et al.  X-Ray Interactions: Photoabsorption, Scattering, Transmission, and Reflection at E = 50-30,000 eV, Z = 1-92 , 1993 .

[43]  E. Vallazza,et al.  Evaluation of charge -sharing effects on the spatial resolution of the PICASSO detector , 2010 .

[44]  Konstantin Ignatyev,et al.  Design of a novel phase contrast x-ray imaging system for mammography. , 2010, Physics in medicine and biology.