In pursuit of high-force/high-stroke conducting polymer actuators (Invited Paper)

Conducting polymer actuators are being investigated for a number of applications. Both linear contracting/expanding and bending type actuators can be constructed that utilise the redox-induced volume changes in the conducting polymer. Improved actuator performance has been demonstrated by modifications to our helix-tube design. The pitch of the helix and bundling the actuators have increased the strain and force generated. Short-term improvements to the strain were also generated using new dopants, but cycle life was poor in this case. Further studies on the mechanism of actuation have continued to focus attention on the influence of the elastic modulus on the actuation strain. Surprising results have been obtained from polythiophene actuators that show an increased strain and increased work-per-cycle with an increasing applied load in isotonic operation. The observations were explained by an increase in modulus during the contraction cycle of the actuation. Preliminary studies show how the change in modulus can be conveniently measured using an in situ mechanical technique.

[1]  Geoffrey M. Spinks,et al.  Carbon nanotube and polyaniline composite actuators , 2003 .

[2]  Geoffrey M. Spinks,et al.  Work-per-cycle analysis for electromechanical actuators , 2005 .

[3]  Dezhi Zhou,et al.  The amounts per cycle of polypyrrole electromechanical actuators , 2003 .

[4]  Keiichi Kaneto,et al.  Polypyrrole–metal Coil Composites as Fibrous Artificial Muscles , 2003 .

[5]  G. Wallace,et al.  Strain Response from Polypyrrole Actuators under Load , 2002 .

[6]  D. De Rossi,et al.  Performance and work capacity of a polypyrrole conducting polymer linear actuator , 1997 .

[7]  I. Hunter,et al.  Fast contracting polypyrrole actuators , 2000 .

[8]  Jie Ding,et al.  High performance conducting polymer actuators utilising a tubular geometry and helical wire interconnects , 2003 .

[9]  R. Baughman Conducting polymer artificial muscles , 1996 .

[10]  D. Rossi,et al.  Characterization and modelling of a conducting polymer muscle-like linear actuator , 1997 .

[11]  M. K. Andrews,et al.  An integrated electrochemical sensor–actuator system , 2004 .

[12]  W. Takashima,et al.  TFSI-doped polypyrrole actuator with 26% strain , 2004 .

[13]  G. Wallace,et al.  Actuators for the cochlear implant , 2003 .

[14]  D. de Rossi,et al.  Actuation Properties of Electrochemically Driven Polypyrrole Free-Standing Films , 1995 .

[15]  K. West,et al.  Mechanism of Actuation in Conducting Polymers: Osmotic Expansion , 2001 .

[16]  Dezhi Zhou,et al.  Conducting polymers electromechanical actuators and strain sensors , 2003 .