DEVELOPMENT OF GUIDELINES FOR THE SEISMIC DESIGN OF BASE ISOLATED STRUCTURES IN MEXICO

This paper summarizes the research efforts conducted in Mexico to develop seismic guidelines for the design of base-isolated structures. The proposed guidelines are based on the seismic provisions of Mexican seismic codes and their philosophy, but include several recommendations available for base-isolated structures in the UBC-97 and IBC-2000 seismic codes of the United States. Additional requirements were added to account for regional seismicity. Finally, new provisions were derived from original research on the torsional response for base-isolated structures and orthogonal effects, among other topics.

[1]  Arturo Tena-Colunga,et al.  TORSIONAL RESPONSE OF BASE-ISOLATED STRUCTURES DUE TO STIFFNESS ASSIMETRIES OF THE ISOLATION SYSTEM , 2002 .

[2]  Arturo Tena-Colunga,et al.  International Seismic Zone Tabulation Proposed by the 1997 UBC Code: Observations for Mexico , 1999 .

[3]  A. Tena EVALUACIÓN DE UN MÉTODO DE DISEÑO ESTÁTICO PARA EL AISLAMIENTO SÍSMICO DE ESTRUCTURAS DE LA COSTA MEXICANA DEL PACÍFICO , 1997 .

[4]  Arturo Tena-Colunga,et al.  Importance of eccentricities in the superstructure on the torsional response of base-isolated structures , 2001 .

[5]  Arturo Tena-Colunga Some Retrofit Options for the Seismic Upgrading of Old Low-Rise School Buildings in Mexico , 1996 .

[6]  Arturo Tena-Colunga,et al.  Seismic Isolation of Buildings Subjected to Typical Subduction Earthquake Motions for the Mexican Pacific Coast , 1997 .

[7]  Arturo Tena-Colunga A NEW METHOD FOR THE SEISMIC DESIGN OF STRUCTURES WITH BILINEAR ISOLATORS USING INELASTIC SPECTRA , 1999 .

[8]  Arturo Tena-Colunga SEISMIC DESIGN OF BASE-ISOLATED STRUCTURES USING CONSTANT STRENGTH SPECTRA , 2002 .

[9]  J. M. Kelly RECENT DEVELOPMENT IN SEISMIC ISOLATION IN THE UNITED STATES , 1999 .

[10]  Jiahao Lin,et al.  An Introduction to Seismic Isolation , 1993 .

[11]  Farzad Naeim,et al.  Design of seismic isolated structures , 1999 .

[12]  Arturo Tena-Colunga,et al.  DYNAMIC DESIGN PROCEDURE FOR THE DESIGN OF BASE ISOLATED STRUCTURES LOCATED ON THE MEXICAN PACIFIC COAST , 1999 .

[13]  Arturo Tena-Colunga,et al.  Torsional response of base-isolated structures due to asymmetries in the superstructure , 2002 .

[14]  Arturo Tena-Colunga,et al.  Design Displacements for Base Isolators considering Bidirectional Seismic Effects , 2006 .

[15]  Michael C. Constantinou,et al.  Torsion in Base‐Isolated Structures with Elastomeric Isolation Systems , 1993 .

[16]  Arturo Tena Colunga DISEÑO DE ESTRUCTURAS CON AISLAMIENTO SÍSMICO MEDIANTE EL USO DE ESPECTROS DE DISEÑO POR CAPACIDAD , 2001 .