Comparison of biomechanical behaviour of maxilla following Le Fort I osteotomy with 2- versus 4-plate fixation using 3D-FEA Part 2: impaction surgery.

The aim of the second part of this study was to evaluate the mechanical behaviour of 2- versus 4-plate fixation and bony structures after Le Fort I impaction surgeries using three-dimensional finite element analysis (3D-FEA). Two 3D-FEA models were created to fixate the impacted maxilla at the Le Fort I level as 2-plate fixation at the piriform rims (IMP-2 model) and 4-plate fixation at the zygomatic buttresses and piriform rims (IMP-4 model). The IMP-2 model contained 225664 elements and 48754 nodes and the IMP-4 model consisted of 245929 elements and 53670 nodes. The stresses in each maxillary model were computed. The models were loaded on one side, at the molar-premolar region, in vertical, horizontal and oblique directions to reflect the chewing process. It was concluded that the use of 4-plate fixation following Le Fort I advancement surgery provides fewer stress fields on the maxillary bones and fixation materials than 2-plate fixation from a mechanical point of view.

[1]  B. Haskell,et al.  One-year postoperative stability of LeFort I osteotomies with biodegradable fixation: a retrospective analysis of skeletal relapse. , 2006, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[2]  R. Haug,et al.  A biomechanical evaluation of mandibular angle fracture plating techniques. , 2001, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[3]  Atilim Eser,et al.  Effects of different inter-implant distances on the stress distribution around endosseous implants in posterior mandible: a 3D finite element analysis. , 2006, Medical engineering & physics.

[4]  P. Brennan,et al.  The skeletal stability of one-piece Le Fort 1 osteotomy to advance the maxilla; Part 1. Stability resulting from non-bone grafted rigid fixation. , 2004, The British journal of oral & maxillofacial surgery.

[5]  M. Ataç,et al.  Comparison of biomechanical behaviour of maxilla following Le Fort I osteotomy with 2- versus 4-plate fixation using 3D-FEA. Part 1: advancement surgery. , 2008, International journal of oral and maxillofacial surgery.

[6]  L. Stassen,et al.  Influence of routine bone grafting on the stability of the non-cleft Le Fort 1 osteotomy. , 2001, British Journal of Oral and Maxillofacial Surgery.

[7]  H. Freihofer,et al.  The behaviour of the maxilla in vertical movements after Le Fort I osteotomy. , 1978, Journal of maxillofacial surgery.

[8]  Bell Wh,et al.  Correction of vertical maxillary deficiency: stability and soft tissue changes. , 1981 .

[9]  B. Epker,et al.  Total maxillary advancement with and without bone grafting. , 1978, Journal of oral surgery.

[10]  A. Nathanson,et al.  Effects of 60CO-γ-Irradiation on Teeth and Jaw Bone in the Rabbit , 1978 .

[11]  T. Turvey,et al.  Stability following superior repositioning of the maxilla by Le Fort I osteotomy: five-year follow-up. , 1994, The International journal of adult orthodontics and orthognathic surgery.

[12]  T. Turvey,et al.  Orthognathic surgery: a hierarchy of stability. , 1996, The International journal of adult orthodontics and orthognathic surgery.

[13]  Bell Wh Le Forte I osteotomy for correction of maxillary deformities. , 1975 .

[14]  P. Major,et al.  Stability of maxilla downgrafting after rigid or wire fixation. , 1996, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[15]  T Nakajima,et al.  Finite element analysis of the stresses around endosseous implants in various reconstructed mandibular models. , 2002, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[16]  T. Turvey,et al.  Stability following superior repositioning of the maxilla by LeFort I osteotomy. , 1987, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[17]  T Nakajima,et al.  Finite element analysis of the stresses around fixtures in various reconstructed mandibular models--part II (effect of horizontal load). , 2003, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[18]  P. Maurer,et al.  Finite element analysis of a tandem screw configuration in sagittal split osteotomy using biodegradable osteosynthesis screws. , 2001, The International journal of adult orthodontics and orthognathic surgery.

[19]  T. Nagasao,et al.  The Dynamic Role of Buttress Reconstruction after Maxillectomy , 2005, Plastic and reconstructive surgery.

[20]  E. Erkmen,et al.  Comparison of different fixation methods following sagittal split ramus osteotomies using three-dimensional finite elements analysis. Part 1: advancement surgery-posterior loading. , 2005, International journal of oral and maxillofacial surgery.

[21]  E. Ellis,et al.  Stability of simultaneous maxillary intrusion and mandibular advancement: a comparison of rigid and nonrigid fixation techniques. , 1988, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[22]  J. V. Van Sickels,et al.  Postsurgical maxillary movement: a comparison study of bone plate and screw versus wire osseous fixation. , 1989, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[23]  T. Turvey,et al.  Simultaneous mobilization of the maxilla and mandible: surgical technique and results. , 1982, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[24]  R. A. West,et al.  Stability of Le Fort I osteotomy with maxillary advancement: a comparison of combined wire fixation and rigid fixation. , 1995, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[25]  U. Joos,et al.  Experimental and finite element study of a human mandible. , 2000, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[26]  B. Epker,et al.  Total maxillary surgery. , 1980, International journal of oral surgery.

[27]  L. Sandvik,et al.  LeFort I maxillary advancement: 3-year stability and risk factors for relapse. , 2005, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[28]  H. Obwegeser SURGICAL CORRECTION OF SMALL OR RETRODISPLACED MAXILLAE The “Dish‐face” Deformity , 1969, Plastic and reconstructive surgery.

[29]  D. Zeitler,et al.  Stability of the Le Fort I maxillary osteotomy after rigid internal fixation. , 1999, Journal of oral and maxillofacial surgery.

[30]  M. Robiony,et al.  Stability of Le Fort I osteotomy in maxillary advancement: review of the literature. , 1999, The International journal of adult orthodontics and orthognathic surgery.

[31]  S. Bishara,et al.  Stability of the LeFort I one-piece maxillary osteotomy. , 1988, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[32]  L. Wolford,et al.  Maxillary stability following downgraft and/or advancement procedures with stabilization using rigid fixation and porous block hydroxyapatite implants. , 1989, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[33]  J. V. Van Sickels,et al.  Stability of orthognathic surgery: a review of rigid fixation. , 1996, The British journal of oral & maxillofacial surgery.

[34]  P. Maurer,et al.  Finite-element-analysis of different screw-diameters in the sagittal split osteotomy of the mandible. , 1999, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[35]  E. Keller,et al.  Stability of the Le Fort I osteotomy with anterior internal fixation alone: a case series. , 2005, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[36]  P. Brennan,et al.  The skeletal stability of one-piece Le Fort 1 osteotomy to advance the maxilla; Part 2. The influence of uncontrollable clinical variables. , 2004, The British journal of oral & maxillofacial surgery.

[37]  P. Waite,et al.  The stability of maxillary advancement using Le Fort I osteotomy with and without genial bone grafting. , 1996, International journal of oral and maxillofacial surgery.

[38]  M. Robiony,et al.  Stability of maxillary advancement for correction of skeletal Class III malocclusion after combined maxillary and mandibular procedures: preliminary results of an active control equivalence trial for semirigid and rigid fixation of the maxilla. , 2002, The International journal of adult orthodontics and orthognathic surgery.

[39]  E. Erkmen,et al.  Three-dimensional finite element analysis used to compare methods of fixation after sagittal split ramus osteotomy: setback surgery-posterior loading. , 2005, The British journal of oral & maxillofacial surgery.

[40]  R. A. Murray,et al.  Comparison of the postsurgical stability of the Le Fort I osteotomy using 2- and 4-plate fixation. , 2003, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[41]  P. Stoelinga,et al.  Long-term stability after inferior maxillary repositioning by miniplate fixation. , 1992, International journal of oral and maxillofacial surgery.