Multiple "slow" CT scans for incorporating lung tumor mobility in radiotherapy planning.

PURPOSE The high local recurrence rates after radiotherapy in early-stage lung cancer may be due to geometric errors that arise when target volumes are generated using fast spiral CT scanners. A "slow" CT technique that generates more representative target volumes was evaluated. METHODS AND MATERIALS Planning CT scans (slice thickness 3 mm, reconstruction index 2.5 mm) were performed during quiet respiration in 10 patients with peripheral lung lesions. Planning CT scans were repeated twice, followed by three slow CT scans (slice thickness 4 mm, index 3 mm, revolution time 4 s/slice). All, except the first scan, were limited to the tumor region. Three-dimensional registration of all scans was performed. The reproducibility of the imaged volumes was evaluated with each technique using (1) the common overlapping volume (COM), the component of the clinical target volume (CTV) covered by all three CT scans, and (2) the encompassing volume (SUM), which is the volume enveloped by all CTVs. RESULTS In all patients, the target volumes generated using slow CT scans were larger than those derived using planning scans (mean ratio of planning-CTV:slow-CTV of 88.8% +/- 5.6%), and also more reproducible. The mean ratio of the respective COM:SUM volumes was 62.6% +/- 10.8% and 54.9% +/- 12.9%. CONCLUSIONS Larger, and more reproducible, target volumes are generated for peripheral lung tumors with the use of slow CT scans, thereby indicating that slow scans can better capture tumor movement.

[1]  K. Lam,et al.  Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing. , 1996, International journal of radiation oncology, biology, physics.

[2]  G. Sibley Radiotherapy for patients with medically inoperable stage I nonsmall cell lung carcinoma , 1998, Cancer.

[3]  H Shirato,et al.  Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[4]  J. Wong,et al.  The use of active breathing control (ABC) to reduce margin for breathing motion. , 1999, International journal of radiation oncology, biology, physics.

[5]  W. Stanford,et al.  Analysis of movement of intrathoracic neoplasms using ultrafast computerized tomography. , 1990, International journal of radiation oncology, biology, physics.

[6]  S Senan,et al.  An analysis of anatomic landmark mobility and setup deviations in radiotherapy for lung cancer. , 1999, International journal of radiation oncology, biology, physics.

[7]  S Senan,et al.  Evaluation of a target contouring protocol for 3D conformal radiotherapy in non-small cell lung cancer. , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  R K Ten Haken,et al.  Estimation of tumor control probability model parameters from 3-D dose distributions of non-small cell lung cancer patients. , 1999, Lung cancer.

[9]  C C Ling,et al.  The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer. , 2000, International journal of radiation oncology, biology, physics.

[10]  B. Heijmen,et al.  Analysis and reduction of 3D systematic and random setup errors during the simulation and treatment of lung cancer patients with CT-based external beam radiotherapy dose planning. , 2001, International journal of radiation oncology, biology, physics.

[11]  E. Noordijk,et al.  Local irradiation alone for peripheral stage I lung cancer: could we omit the elective regional nodal irradiation? , 1996, International journal of radiation oncology, biology, physics.