The “Z‐effect” phenomenon defined: A laboratory study

The Z‐effect phenomenon is a potential complication of two lag screw intramedullary nail designs used for fixation of intertrochanteric hip fractures, in which the inferior lag screw migrates laterally and the superior lag screw migrates medially during physiologic loading. The current investigation was undertaken in an attempt to reproduce the Z‐effect phenomenon in a laboratory setting. Sixteen different simulated femoral head and neck constructs having varying compressive strengths were created using four densities of solid polyurethane foam and instrumented with a two‐screw cephalomedullary intramedullary nail. Each specimen was then cyclically loaded with 250 N vertical loads applied for 10, 100, 1000, and 10,000 cycles. Measurement of screw displacement with respect to the lateral aspect of the intramedullary nail was made after each cyclic increment. The inferior lag screw migration component of the Z‐effect phenomenon was reproduced in specimens with head compressive strengths that were higher than the compressive strengths of the neck. Specimens with the greatest difference in head–neck compressive strength demonstrated the most significant displacement of the inferior lag screw without any displacement of the superior lag screw. Specimens with a femoral neck compressive strength of 0.91 MPa of and a head compressive strength of 8.8 MPa resulted in more than one centimeter of inferior lag screw lateral migration after 10,000 cycles of vertical loading. Models where the femoral head had a higher compressive strength than that of the femoral neck may simulate fracture patterns with significant medial cortex comminution that are prone to varus collapse. © 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 25:1568–1573, 2007

[1]  E. Lambiris,et al.  A randomised comparison of AMBI, TGN and PFN for treatment of unstable trochanteric fractures , 2005, Archives of Orthopaedic and Trauma Surgery.

[2]  James A. Johnson,et al.  Mechanical properties of cancellous bone of the distal humerus. , 2005, Clinical biomechanics.

[3]  M. Tyllianakis,et al.  Treatment of extracapsular hip fractures with the proximal femoral nail (PFN): long term results in 45 patients. , 2004, Acta orthopaedica Belgica.

[4]  M. Bottlang,et al.  A Laboratory Model to Evaluate Cutout Resistance of Implants for Pertrochanteric Fracture Fixation , 2004, Journal of orthopaedic trauma.

[5]  Erik N. Kubiak,et al.  Intramedullary Fixation of Unstable Intertrochanteric Hip Fractures: One or Two Lag Screws , 2004, Journal of orthopaedic trauma.

[6]  E W Steyerberg,et al.  Treatment of unstable trochanteric fractures. Randomised comparison of the gamma nail and the proximal femoral nail. , 2004, Journal of Bone and Joint Surgery-british Volume.

[7]  W. Grechenig,et al.  The proximal femoral nail (PFN) - a minimal invasive treatment of unstable proximal femoral fractures: A prospective study of 55 patients with a follow-up of 15 months , 2003, Acta orthopaedica Scandinavica.

[8]  W. Werner-Tutschku,et al.  Intra- und perioperative Komplikationen bei der Stabilisierung von per- und subtrochantären Femurfrakturen mittels PFN® , 2002, Der Unfallchirurg.

[9]  M. Al-Lami,et al.  The AO/ASIF proximal femoral nail (PFN) for the treatment of unstable trochanteric femoral fracture. , 2002, Injury.

[10]  A. Hart,et al.  The treatment of unstable, extracapsular hip fractures with the AO/ASIF proximal femoral nail (PFN)--our first 60 cases. , 2002, Injury.

[11]  G. Lajtai,et al.  [Intra- and perioperative complications in the stabilization of per- and subtrochanteric femoral fractures by means of PFN]. , 2002, Der Unfallchirurg.

[12]  A. Miles,et al.  Failure of femoral head fixation: a cadaveric analysis of lag screw cut-out with the gamma locking nail and AO dynamic hip screw. , 1997, Injury.

[13]  S. Nafie,et al.  Comparison of dynamic hip screw and gamma nail: a prospective, randomized, controlled trial. , 1995, Injury.

[14]  A. Patel,et al.  Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw. , 1991, The Journal of bone and joint surgery. British volume.

[15]  R F Kyle,et al.  Biomechanical analysis of the sliding characteristics of compression hip screws. , 1980, The Journal of bone and joint surgery. American volume.