Comparison of intravenous coronary angiography using synchrotron radiation with selective coronary angiography.

Intravenous coronary angiography with synchrotron radiation is a novel and minimally invasive technique for coronary imaging. At the Hamburger Synchrotronstrahlungslabor HASYLAB at DESY, a dedicated angiography system has been developed, which has been shown to provide detailed images of coronary artery segments. For each scan, two monochromatic X-ray images below and above the K-edge of iodine were recorded simultaneously. The two images were subtracted logarithmically to produce a maximal contrast enhancement of the iodine. To date, the procedure has been carried out on 379 outpatients. No complications occurred during or after the angiographic procedure, and hospitalization was not required in any subject. The acceptance by patient is extremely high. Five outside reviewers, blinded as to the clinical data or prior angiographic interpretation, reviewed the images for the presence or absence of 70% or more occlusion of a vessel. They reached a sensitivity of 79% and a specificity of 99%. The study has demonstrated that the synchrotron method has satisfactory sensitivity and very high specificity for severe stenoses. The new method has several advantages over magnetic resonance imaging (MRI), electron beam computed tomography (EBCT), and multi-slice computed tomography (MSCT). Neither vascular calcification (CT) nor the presence of metal stents (MRI) impairs the evaluation of perfusion of segments of the coronary arteries. Furthermore, the spatial resolution is three or four times higher using synchrotron angiography, and problems due to respiratory motion are eliminated.

[1]  Matthijs Oudkerk,et al.  Coronary angiography with multi-slice computed tomography , 2001, The Lancet.

[2]  W.-R. Dix,et al.  Intravenous coronary angiography with synchrotron radiation , 1998, CARS.

[3]  Werner Moshage,et al.  Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT. , 2000 .

[4]  Fulvia Arfelli,et al.  Synchrotron light and imaging systems for medical radiology , 2000 .

[5]  G D Rubin,et al.  Coronary artery angiography using multislice computed tomography images. , 2000, Circulation.

[6]  Forster,et al.  Yield optimization and time structure of femtosecond laser plasma kalpha sources , 2000, Physical review letters.

[7]  T. Callister,et al.  Identification of patients at increased risk of first unheralded acute myocardial infarction by electron-beam computed tomography. , 2000, Circulation.

[8]  O. Morel,et al.  Three-dimensional coronary artery MR imaging using prospective real-time respiratory navigator and linear phase shift processing: comparison with conventional coronary angiography. , 1999, Magnetic resonance imaging.

[9]  T Takeda,et al.  Dynamic intravenous coronary angiography using 2D monochromatic synchrotron radiation. , 1999, The British journal of radiology.

[10]  S. Achenbach,et al.  Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions. , 1998, The New England journal of medicine.

[11]  B. Reime,et al.  A HIGH SENSITIVE TWO-LINE DETECTOR WITH LARGE DYNAMIC RANGE FOR INTRAVENOUS CORONARY ANGIOGRAPHY , 1998 .

[12]  B Barzilai,et al.  Detection of coronary stenoses on source and projection images using three-dimensional MR angiography with retrospective respiratory gating: preliminary experience. , 1998, AJR. American journal of roentgenology.

[13]  S. Achenbach,et al.  Detection of high-grade restenosis after PTCA using contrast-enhanced electron beam CT. , 1997, Circulation.

[14]  W.-R. Dix,et al.  Double beam bent Laue monochromator for coronary angiography , 1995 .

[15]  A. Duerinckx,et al.  Two-dimensional coronary MR angiography: analysis of initial clinical results. , 1994, Radiology.

[16]  J. Sellschop,et al.  High intensity electron channeling and perspectives for a bright tunable x‐ray source , 1990 .

[17]  江橋 節郎,et al.  Handbook on synchrotron radiation , 1983 .

[18]  R. Sievert,et al.  Book Reviews : Recommendations of the International Commission on Radiological Protection (as amended 1959 and revised 1962). I.C.R.P. Publication 6. 70 pp. PERGAMON PRESS. Oxford, London and New York, 1964. £1 5s. 0d. [TB/54] , 1964 .

[19]  B. Jacobson,et al.  Dichromatic absorption radiography; dichromography. , 1953, Acta radiologica.