Die elektronische Volumenbestimmung von Blutkörperchen und ihre Fehlerquellen

SummaryThe electronic determination of volume of the corpuscular blood components is more accurate and quicker than optical methods. The main source of error with the coulter instrument is the unequal current density in the cell-sizing aperture. This error was discovered by comparative examinations with the electron microscope, experiments using an enlarged model (electrolytic tank), and oscillographic puls shape analysis. This error in the measurement system causes the artificial positive skewness of the volume distribution curve. This error is avoided using a new device which permits exact volume determination in a homogeneous electric field without coincidence error. Form factors can be neglected in the determination of erythrocyte volume. They are only of importance in measuring the absolute volume of leukocytes as well as for calibrating instruments with latex-particles.ZusammenfassungDie elektronische Volumenbestimmung der corpusculären Bestandteile des Blutes zeichnet sich gegenüber optischen Methoden durch grö\ere Genauigkeit und eine sehr hohe Me\geschwindigkeit aus. Die wesentliche Fehlerquelle bei den Coulterschen Geräten, die unterschiedliche Stromdichte in der Me\öffnung der Glascapillare, wurde durch elektronenmikroskopische Referenzuntersuchungen, Messungen am vergrö\erten Modell und Impulsbildanalysen aufgedeckt. Dieser systematische Fehler verursacht die artifizielle Rechtsschiefe der Erythrocytenvolumenverteilungskurve. Er entfällt bei Anwendung einer modifizierten Capillare, die unverfälschte Volumenbestimmungen durch Messungen im homogenen elektrischen Feld ermöglicht. — Formfaktoren können für die Volumenbestimmung der Erythrocyten vernachlässigt werden. Ihre Berücksichtigung ist zur Ermittlung des Absolutvolumens der Leukocyten sowie zur Gerätekalibrierung mit Latexpartikeln unerlä\lich.

[1]  J. Grant,et al.  Measurement of red blood cell volume with the electronic cell counter. , 1960, American journal of clinical pathology.

[2]  G. Ruhenstroth-Bauer,et al.  [The mechanism of blood cell sedimentation. XIV. The effect of lysolecithin and nonesterified fatty acids on the blood cell sedimentation rate]. , 1969, Blut.

[3]  C C LUSHBAUGH,et al.  Electronic measurement of cellular volumes. II. Frequency distribution of erythrocyte volumes. , 1961, LA [reports]. U.S. Atomic Energy Commission.

[4]  R. Skalak,et al.  Deformation of Red Blood Cells in Capillaries , 1969, Science.

[5]  S Chien,et al.  Flow Characteristics of Human Erythrocytes through Polycarbonate Sieves , 1967, Science.

[6]  H. Fricke,et al.  A Mathematical Treatment of the Electric Conductivity and Capacity of Disperse Systems I. The Electric Conductivity of a Suspension of Homogeneous Spheroids , 1924 .

[7]  E. C. Gregg,et al.  Electrical counting and sizing of mammalian cells in suspension. , 1965, Biophysical journal.

[8]  B S Bull,et al.  On the distribution of red cell volumes. , 1968, Blood.

[9]  R I Weed,et al.  The influence of hemoglobin concentration on the distribution pattern of the volumes of human erythrocytes. , 1967, Blood.

[10]  H Winter,et al.  The skewness of volume distribution curves of erythrocytes. , 1965, The Australian journal of experimental biology and medical science.

[11]  G. Brecher,et al.  SIZE DISTRIBUTION OF ERYTHROCYTES , 1962, Annals of the New York Academy of Sciences.

[12]  J. GUTMANN Elektronische Verfahren zur Ermittlung statistischer Maßzahlen einiger medizinisch wichtiger Daten , 1966 .

[13]  M. Ingram,et al.  Red cell volumes and erythropoiesis. II. Age: density: volume relationships of macrocytes. , 1968, The American journal of physiology.

[14]  D. B. Nevius Osmotic error in electronic determinations of red cell volume. , 1963, American Journal of Clinical Pathology.

[15]  C C Lushbaugh,et al.  Some Effects of Electrical Fields on Red Blood Cells with Remarks on Electronic Red Cell Sizing , 1968, British journal of haematology.