Detection of Abnormal Respiration from Multiple-Input Respiratory Signals

In this paper, we propose a novel approach for the detection of abnormal signals from multiple respiration signals. An ultrawide-band (UWB) radar was used to acquire respiration signals that represent a distance from the chest to the radar sensor, i.e., shape variation of the chest due to breathing (inhaling or exhaling) activity provides quantitative information (distance values) about respiratory status. Distribution, shape, and variation of values across time provide information to determine respiratory status, one of the most important indicators of human health. In this paper, respiratory status was categorized into two classes, normal and abnormal. Abnormal respiration (apnea in this paper) was emulated by interrupting breathing activity because it is difficult to acquire real apnea from patients in hospital wards. This paper considered two cases, single and multiple respiration. In the first case, a single normal- or abnormal-respiration signal was used as input, and output was the classified status of respiration. In the second case, multiple respiration signals were simultaneously used as inputs, and we focused on determining the existence of abnormal signals in multiple respiration signals. In the case of multiple inputs, filters with varying cut-off frequency were applied to input signals followed by the analysis of output signals in response to the filters. To substantiate the proposed method, experiment results are provided. In this paper, classification results showed 93% of the successful rate in the case of multiple inputs, and results are promising for applications to monitoring systems of human respiration.

[1]  Robin J. Evans,et al.  Noncontact Detection and Analysis of Respiratory Function Using Microwave Doppler Radar , 2015, J. Sensors.

[2]  Mohammad B. Shamsollahi,et al.  ECG-derived respiration estimation from single-lead ECG using gaussian process and phase space reconstruction methods , 2018, Biomed. Signal Process. Control..

[3]  Ben Richard Hughes,et al.  Medical Devices for Measuring Respiratory Rate in Children: a Review , 2016 .

[4]  Xiaohua Zhu,et al.  Doppler radar-based human breathing patterns classification using Support Vector Machine , 2017, 2017 IEEE Radar Conference (RadarConf).

[5]  David Sarrut,et al.  Multi-dimensional respiratory motion tracking from markerless optical surface imaging based on deformable mesh registration , 2012, Physics in medicine and biology.

[6]  Sergio Silvestri,et al.  Contact-Based Methods for Measuring Respiratory Rate , 2019, Sensors.

[7]  Aurobinda Routray,et al.  Infrared imaging based hyperventilation monitoring through respiration rate estimation , 2016 .

[8]  Yee Siong Lee,et al.  Monitoring and Analysis of Respiratory Patterns Using Microwave Doppler Radar , 2014, IEEE Journal of Translational Engineering in Health and Medicine.

[9]  Miad Faezipour,et al.  Automatic detection and classification of acoustic breathing cycles , 2014, Proceedings of the 2014 Zone 1 Conference of the American Society for Engineering Education.

[10]  Sung Ho Cho,et al.  IR-UWB Radar Sensor for Human Gesture Recognition by Using Machine Learning , 2016, 2016 IEEE 18th International Conference on High Performance Computing and Communications; IEEE 14th International Conference on Smart City; IEEE 2nd International Conference on Data Science and Systems (HPCC/SmartCity/DSS).

[11]  Se Dong Min,et al.  Noncontact Respiration Rate Measurement System Using an Ultrasonic Proximity Sensor , 2010, IEEE Sensors Journal.

[12]  Yaniv Zigel,et al.  Breathing rate estimation during sleep using audio signal analysis , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[13]  Sung Ho Cho,et al.  Hand-Based Gesture Recognition for Vehicular Applications Using IR-UWB Radar , 2017, Sensors.

[14]  Guanghao Sun,et al.  Rapid and stable measurement of respiratory rate from Doppler radar signals using time domain autocorrelation model , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[15]  Ki H. Chon,et al.  Estimation of Respiratory Rates Using the Built-in Microphone of a Smartphone or Headset , 2016, IEEE Journal of Biomedical and Health Informatics.

[16]  Nadi Sadr,et al.  Sleep apnoea classification using heart rate variability, ECG derived respiration and cardiopulmonary coupling parameters , 2016, 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[17]  Jean-Marc Vesin,et al.  Respiratory rate estimation from the ECG using an instantaneous frequency tracking algorithm , 2014, Biomed. Signal Process. Control..

[18]  Gian-Luca Bona,et al.  An Optical Fibre-Based Sensor for Respiratory Monitoring , 2014, Sensors.

[19]  Patrizia Vergallo,et al.  Empirical Mode Decomposition vs. Wavelet Decomposition for the Extraction of Respiratory Signal From Single-Channel ECG: A Comparison , 2013, IEEE Sensors Journal.

[20]  Vineet Kumarand,et al.  Estimation of Respiration rate from ECG Using Canonical Components Analysis and Ensemble Empirical Mode Decomposition , 2015, Bio-Science and Bio-Technology.

[21]  R. Saatchi,et al.  Respiration rate monitoring methods: A review , 2011, Pediatric pulmonology.

[22]  P. Laguna,et al.  Electrocardiogram Derived Respiratory Rate from QRS Slopes and R-Wave Angle , 2014, Annals of Biomedical Engineering.

[23]  Pubudu N. Pathirana,et al.  Motion artefact separation in single channel Doppler radar respiration measurement , 2015, 2015 International Symposium on Bioelectronics and Bioinformatics (ISBB).

[24]  Fatih Erden,et al.  Contact-free measurement of respiratory rate using infrared and vibration sensors , 2015 .

[25]  Zong Woo Geem,et al.  A Novel Human Respiration Pattern Recognition Using Signals of Ultra-Wideband Radar Sensor , 2019, Sensors.

[26]  Tapio Seppänen,et al.  ECG-derived respiration methods: adapted ICA and PCA. , 2015, Medical engineering & physics.

[27]  Yuting Yang,et al.  Noncontact Monitoring Breathing Pattern, Exhalation Flow Rate and Pulse Transit Time , 2014, IEEE Transactions on Biomedical Engineering.

[28]  A. Stefanovska,et al.  Importance of wavelet analysis in laser Doppler flowmetry time series , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.