Development of a simplified and dynamic method for double glazing façade with night insulation and validated by full-scale façade element

Abstract The study aims to develop a simplified calculation method to simulate the performance of double glazing facade with night insulation. This paper describes the method to calculate the thermal properties (U-value) and comfort performance (internal surface temperature of glazing) of the double glazing facade with the night insulation. The calculation result of the internal glazing surface temperature has been validated with experimental data collected in a full-scale facade element test facility at Aalborg University (DK). With the help of the simplified method, dynamic U-value of the facade with night insulation is calculated and compared with that of the facade without the night insulation. Based on standards EN 410 and EN 673, the method takes the thermal mass of glazing and the infiltration between the insulation layer and glazing into account. Furthermore it is capable of implementing whole year calculation at different time steps. Acceptable accuracy and simplicity inputs are also the advantages of the method, which make it a suitable tool to evaluate the performance of night insulation during the design stage of buildings. The result calculated by the method proves that the facade with the night insulation performs much better than that without the night insulation.

[1]  S. N. Garg,et al.  An empirical model for angle-dependent g-values of glazings , 2010 .

[2]  Biswanath Roy,et al.  Heat transfer modelling on windows and glazing under the exposure of solar radiation , 2009 .

[3]  P. H. Baker,et al.  Air flow through cracks , 1987 .

[4]  Keith Nicol The thermal effectiveness of various types of window coverings , 1986 .

[5]  Tilmann E. Kuhn Solar control : A general evaluation method for facades with venetian blinds or other solar control systems , 2006 .

[6]  Per Heiselberg,et al.  Development of Simplified and Dynamic Model for Double Glazing Unit Validated with Full-Scale Facade Element , 2012 .

[7]  J. Xamán,et al.  Thermal analysis for a double glazing unit with and without a solar control film (SnS-CuxS) for using in hot climates , 2011 .

[8]  Kim Bjarne Wittchen,et al.  BSim User's Guide , 2008 .

[9]  Per Heiselberg,et al.  Experimental Set-up and Full-scale measurements in the ‘Cube' , 2008 .

[10]  Rasmus Lund Jensen,et al.  Temperature Measurements Using Type K Thermocouples and the Fluke Helios Plus 2287A Datalogger , 2008 .

[11]  Rasmus Lund Jensen,et al.  Intelligent Glazed Facades for Fulfilment of Future Energy Regulations , 2010 .

[12]  Robert Hart,et al.  Thermal Performance Impacts of Center-of-Glass Deflections in Installed Insulating Glazing Units , 2012 .

[13]  A. Roos,et al.  Modelling the angular behaviour of the total solar energy transmittance of windows , 2000 .

[14]  Dirk Saelens,et al.  Energy Performance Assessment of Multiple-Skin Facades , 2003 .

[15]  M. Zaheer-Uddin Dynamic effects of thermal shutters , 1990 .

[16]  J. Rosenfeld,et al.  Optical and thermal performance of glazing with integral venetian blinds , 2001 .