Influence of network parameters on the recovery time of a ring topology PROFINET network

Abstract: This paper proposes a study on the use of ring topology to increase availability of PROFINET networks. It discusses the influence of Media Redundancy Protocol (MRP), watchdog time, and the computational power of the PROFINET Controller on the communication recovery time after a ring fracture. The paper proposes to consider two main contributions to the overall recovery time: the first is related to the low level (Ethernet layer 2) redundancy management, while the second is related to the software configuration of the entire network. Several different configurations of networks have been created in laboratory and many others have been analyzed in real industry plants. The collected results show how watchdog could influence recovery time since its violation could trigger higher level routines whose duration is basically set by PROFINET controller computational capability. On balance, relevant suggestions to increase the availability of PROFINET networks are pointed out.

[1]  W. Kastner,et al.  The Evolution of Factory and Building Automation , 2011, IEEE Industrial Electronics Magazine.

[2]  Goran Martinovic,et al.  Model of influence of MRP on network performances , 2013, 2013 IEEE Symposium on Computers and Communications (ISCC).

[3]  Mats Björkman,et al.  Introducing security modules in PROFINET IO , 2009, 2009 IEEE Conference on Emerging Technologies & Factory Automation.

[4]  Daniele Marioli,et al.  Evaluation of timing characteristics of a prototype system based on PROFINET IO RT_Class 3 , 2007, 2007 IEEE Conference on Emerging Technologies and Factory Automation (EFTA 2007).

[5]  Emiliano Sisinni,et al.  On the Seamless Interconnection of IEEE1588-Based Devices Using a PROFINET IO Infrastructure , 2010, IEEE Transactions on Industrial Informatics.

[6]  Max Felser,et al.  Real-Time Ethernet - Industry Prospective , 2005, Proceedings of the IEEE.

[7]  M. Felser Media Redundancy for PROFINET IO , 2008, 2008 IEEE International Workshop on Factory Communication Systems.

[8]  Henning Trsek,et al.  Towards autoconfiguration of industrial automation systems: A case study using Profinet IO , 2012, Proceedings of 2012 IEEE 17th International Conference on Emerging Technologies & Factory Automation (ETFA 2012).

[9]  Daniele Fontanelli,et al.  A Servo-Clock Model for Chains of Transparent Clocks Affected by Synchronization Period Jitter , 2014, IEEE Transactions on Instrumentation and Measurement.

[10]  Alessandra Flammini,et al.  Large PROFINET IO RT networks for factory automation: A case study , 2011, ETFA2011.