Extraction of the respiratory signal from small-animal CT projections for a retrospective gating method

We propose a retrospective respiratory gating algorithm to generate dynamic CT studies. To this end, we compared three different methods of extracting the respiratory signal from the projections of small-animal cone-beam computed tomography (CBCT) scanners. Given a set of frames acquired from a certain axial angle, subtraction of their average image from each individual frame produces a set of difference images. Pixels in these images have positive or negative values (according to the respiratory phase) in those areas where there is lung movement. The respiratory signals were extracted by analysing the shape of the histogram of these difference images: we calculated the first four central and non-central moments. However, only odd-order moments produced the desired breathing signal, as the even-order moments lacked information about the phase. Each of these curves was compared to a reference signal recorded by means of a pneumatic pillow. Given the similar correlation coefficients yielded by all of them, we selected the mean to implement our retrospective protocol. Respiratory phase bins were separated, reconstructed independently and included in a dynamic sequence, suitable for cine playback. We validated our method in five adult rat studies by comparing profiles drawn across the diaphragm dome, with and without retrospective respiratory gating. Results showed a sharper transition in the gated reconstruction, with an average slope improvement of 60.7%.

[1]  A. Nagy,et al.  Mouse models of human disease , 2000, Clinical genetics.

[2]  George Starkschall,et al.  Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: Part I--correlating internal lung motion with skin fiducial motion. , 2004, International journal of radiation oncology, biology, physics.

[3]  M. Desco,et al.  Assessment of a New High-Performance Small-Animal X-Ray Tomograph , 2008, IEEE Transactions on Nuclear Science.

[4]  I. Black,et al.  A comparison of target-controlled infusion versus volatile inhalant anesthesia for heart rate, respiratory rate, and recovery time in a rat model. , 2005, Contemporary topics in laboratory animal science.

[5]  Jeffrey D Bradley,et al.  Comparison of spirometry and abdominal height as four-dimensional computed tomography metrics in lung. , 2005, Medical physics.

[6]  Sasa Mutic,et al.  Quantitation of the reconstruction quality of a four-dimensional computed tomography process for lung cancer patients. , 2005, Medical physics.

[7]  L Xing,et al.  Motion correction for improved target localization with on-board cone-beam computed tomography , 2006, Physics in medicine and biology.

[8]  Masayuki Suzuki,et al.  Computerized Methods for Determining Respiratory Phase on Dynamic Chest Radiographs Obtained by a Dynamic Flat-Panel Detector (FPD) System , 2004, Journal of Digital Imaging.

[9]  R. Mohan,et al.  Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. , 2003, Physics in medicine and biology.

[10]  L. Xing,et al.  Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy. , 2007, International journal of radiation oncology, biology, physics.

[11]  Vincent Servois,et al.  Lung volume assessment for a cross-comparison of two breathing-adapted techniques in radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[12]  J. Fessler,et al.  Estimating 3D respiratory motion from orbiting views , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[13]  M. Swindle,et al.  Vascular access port (VAP) usage in large animal species. , 2005, Contemporary topics in laboratory animal science.

[14]  Suresh Senan,et al.  Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage I lung cancer. , 2004, International journal of radiation oncology, biology, physics.

[15]  Jicun Hu,et al.  Dynamic small animal lung imaging via a postacquisition respiratory gating technique using micro-cone beam computed tomography. , 2004, Academic radiology.

[16]  C. Ling,et al.  Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning. , 2002, Medical physics.

[17]  Marcel van Herk,et al.  Image-guided radiotherapy for lung cancer: Respiration-correlated (cone-beam) CT to verify tumor position and motion characteristics during treatment delivery , 2004 .

[18]  M Alber,et al.  An algorithm for automatic determination of the respiratory phases in four-dimensional computed tomography. , 2006, Physics in medicine and biology.

[19]  R. Mohan,et al.  Correlation between internal fiducial tumor motion and external marker motion for liver tumors imaged with 4D-CT. , 2007, International journal of radiation oncology, biology, physics.

[20]  David A. Jaffray,et al.  Respiratory Gated Cone-Beam CT Volumetric Imaging for External Beam Radiotherapy , 2005 .

[21]  L. Xing,et al.  Image interpolation in 4D CT using a BSpline deformable registration model. , 2006, International journal of radiation oncology, biology, physics.

[22]  Maria Drangova,et al.  Fast Retrospectively Gated Quantitative Four-Dimensional (4D) Cardiac Micro Computed Tomography Imaging of Free-Breathing Mice , 2007, Investigative radiology.

[23]  G. Fullerton,et al.  Evaluation of computed tomography numbers for treatment planning of lung cancer. , 1982, International journal of radiation oncology, biology, physics.

[24]  B. Jose,et al.  Computed tomography and radiotherapy in the treatment of cancer , 1983, Journal of surgical oncology.

[25]  Simon Rit,et al.  Respiratory Signal Extraction for 4D CT Imaging of the Thorax from Cone-Beam CT Projections , 2005, MICCAI.

[26]  Maria Drangova,et al.  Prospective respiratory-gated micro-CT of free breathing rodents. , 2005, Medical physics.

[27]  Cameron J. Ritchie,et al.  Respiratory compensation in projection imaging using a magnification and displacement model , 1996, IEEE Trans. Medical Imaging.

[28]  Tinsu Pan,et al.  Four-dimensional computed tomography: image formation and clinical protocol. , 2005, Medical physics.

[29]  M. V. van Herk,et al.  Respiratory correlated cone beam CT. , 2005, Medical physics.

[30]  Wei Lu,et al.  Generation of 4D CT Image Data and Analysis of Lung Tumour Mobility during the Breathing Cycle , 2006, MIE.

[31]  Pierre Grangeat,et al.  Theoretical framework for a dynamic cone-beam reconstruction algorithm based on a dynamic particle model. , 2002, Physics in medicine and biology.

[32]  Eike Rietzel,et al.  Improving retrospective sorting of 4D computed tomography data. , 2006, Medical physics.

[33]  G. Christensen,et al.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. , 2003, Medical physics.

[34]  Russell H. Taylor,et al.  Lung Deformation Estimation and Four-Dimensional CT Lung Reconstruction , 2005, MICCAI.

[35]  James M Balter,et al.  Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines. , 2004, Medical physics.

[36]  L. Hedlund,et al.  Micro-CT with respiratory and cardiac gating. , 2004, Medical physics.

[37]  J. Ehrhardt,et al.  An optical flow based method for improved reconstruction of 4D CT data sets acquired during free breathing. , 2007, Medical physics.

[38]  Maria Drangova,et al.  Optimization of a retrospective technique for respiratory-gated high speed micro-CT of free-breathing rodents , 2007, Physics in Medicine and Biology.

[39]  J. McClelland,et al.  A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy. , 2006, Medical physics.

[40]  T. Pan,et al.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. , 2004, Medical physics.

[41]  T. Guerrero,et al.  Acquiring 4D thoracic CT scans using a multislice helical method. , 2004, Physics in medicine and biology.

[42]  E A Hoffman,et al.  In vivo micro-CT lung imaging via a computer-controlled intermittent iso-pressure breath hold (IIBH) technique , 2006, Physics in medicine and biology.

[43]  Tinsu Pan,et al.  Dynamic ventilation imaging from four-dimensional computed tomography , 2006, Physics in medicine and biology.

[44]  C. Koch,et al.  In regard to Vordermark et al. (Int J Radiat Oncol Biol Phys 2004;58:1242-1250). , 2004, International journal of radiation oncology, biology, physics.

[45]  Timothy D. Solberg,et al.  Phase versus amplitude sorting of 4D‐CT data , 2006, Journal of applied clinical medical physics.

[46]  Maria Drangova,et al.  Prospective respiratory-gated micro-CT of free breathing rodents. , 2005, Medical physics.