Image reconstruction in intravascular photoacoustic imaging
暂无分享,去创建一个
Pai-Chi Li | Cheng-Ying Chou | Bao-Yu Hsieh | Yae-lin Sheu | Pai-Chi Li | Bao-Yu Hsieh | Yae-Lin Sheu | Cheng-Ying Chou
[1] Xu Xiao. Photoacoustic imaging in biomedicine , 2008 .
[2] Lihong V. Wang,et al. Reconstructions in limited-view thermoacoustic tomography. , 2004, Medical physics.
[3] Minghua Xu,et al. Time-domain reconstruction algorithms and numerical simulations for thermoacoustic tomography in various geometries , 2003, IEEE Transactions on Biomedical Engineering.
[4] Hao Zhang,et al. Imaging of hemoglobin oxygen saturation variations in single vessels in vivo using photoacoustic microscopy , 2007 .
[5] Jeffrey A. Fessler,et al. Spatial resolution properties of penalized-likelihood image reconstruction: space-invariant tomographs , 1996, IEEE Trans. Image Process..
[6] Yuan Xu,et al. Exact frequency-domain reconstruction for thermoacoustic tomography. I. Planar geometry , 2002, IEEE Transactions on Medical Imaging.
[7] Minghua Xu,et al. Time-domain reconstruction for thermoacoustic tomography in a spherical geometry , 2002, IEEE Transactions on Medical Imaging.
[8] Bo Wang,et al. Photoacoustic imaging of coronary artery stents. , 2009, Optics express.
[9] Lihong V. Wang,et al. Photoacoustic tomography of the mouse cerebral cortex with a high-numerical-aperture-based virtual point detector. , 2009, Journal of biomedical optics.
[10] Mark A. Anastasio,et al. Comparison of iterative reconstruction approaches for photoacoustic tomography , 2007, SPIE BiOS.
[11] Mark A. Anastasio,et al. An Imaging Model Incorporating Ultrasonic Transducer Properties for Three-Dimensional Optoacoustic Tomography , 2011, IEEE Transactions on Medical Imaging.
[12] Mark A. Anastasio,et al. Compensation for transducer effects in optoacoustic tomography , 2010, BiOS.
[13] Minghua Xu,et al. Exact frequency-domain reconstruction for thermoacoustic tomography. II. Cylindrical geometry , 2002, IEEE Transactions on Medical Imaging.
[14] Xiaochuan Pan,et al. Data redundancy and reduced-scan reconstruction in reflectivity tomography , 2003, IEEE Trans. Image Process..
[15] Bo Wang,et al. Development of catheters for combined intravascular ultrasound and photoacoustic imaging , 2009, BiOS.
[16] Adam D. Maxwell,et al. High-sensitivity polymer microring resonators for broadband ultrasound detection and imaging , 2008, SPIE BiOS.
[17] Mark A. Anastasio,et al. Application of inverse source concepts to photoacoustic tomography , 2007 .
[18] S. Ashkenazi,et al. Polymer microring resonators for high-sensitivity and wideband photoacoustic imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[19] Minghua Xu,et al. Analytic explanation of spatial resolution related to bandwidth and detector aperture size in thermoacoustic or photoacoustic reconstruction. , 2003, Physical review. E, Statistical, nonlinear, and soft matter physics.
[20] L. Jay Guo,et al. Design and fabrication of an integrated intravascular ultrasound/photoacoustic scan head , 2010, BiOS.
[21] Sheng-Wen Huang,et al. Low-noise wideband ultrasound detection using polymer microring resonators. , 2008, Applied physics letters.
[22] Jin Zhang,et al. Weighted expectation maximization reconstruction algorithms for thermoacoustic tomography , 2005, IEEE Transactions on Medical Imaging.
[23] S. Emelianov,et al. Intravascular photoacoustic imaging using an IVUS imaging catheter , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[24] Shriram Sethuraman,et al. Spectroscopic intravascular photoacoustic imaging to differentiate atherosclerotic plaques. , 2008, Optics express.
[25] Meng-Lin Li,et al. Model-based correction of finite aperture effect in photoacoustic tomography. , 2010, Optics express.
[26] A. Welch,et al. A review of the optical properties of biological tissues , 1990 .