Simultaneous endocardial mapping in the human left ventricle using a noncontact catheter: comparison of contact and reconstructed electrograms during sinus rhythm.

BACKGROUND Catheter ablation of ventricular tachycardia is limited in part by difficulty in identifying suitable sites for ablation. A noncontact multielectrode array (MEA) has been developed that allows reconstruction of 3360 electrograms, using inverse-solution mathematics, that are superimposed onto a computer-simulated model of the endocardium. This study assesses the accuracy of timing and morphology of reconstructed unipolar electrograms compared with contact unipolar electrograms from the same endocardial site. METHODS AND RESULTS The MEA was deployed in the left ventricles of 13 patients (end-diastolic diameters, 61.7+/-8.4 mm [mean+/-SD]). We recorded contact electrograms at 76 points equatorial and 32 points nonequatorial to the MEA during sinus rhythm using a catheter-locator signal to record direction and distance from the MEA. Morphology (cross-correlation) and timing of maximum -dV/dt of contact and reconstructed electrograms were compared at different distances from the MEA center to endocardium (M-E) and from the MEA equatorial plane. For equatorial data, the M-E was 32.12+/-12.12 mm. The timing of reconstructed with respect to contact electrograms was -1.94+/-7.12 ms for M-E <34 mm and -14.16+/-19.29 ms at M-E >34 mm (P<0.001). Cross-correlation of electrograms was 0.87+/-0.12 (95% CI, 0.84 to 0.91) and 0.76+/-0.18 (95% CI, 0.69 to 0.83) for M-E <34 mm and >34 mm, respectively. Nonequatorial points were 32.33+/-10.81 mm (range, 16.9 to 55.6 mm) from the MEA equatorial plane; electrogram timing difference was -8.97+/-15.75 ms and was unrelated to this distance from the equator. CONCLUSIONS This noncontact mapping system accurately reconstructs endocardial unipolar electrograms from the human left ventricle. At M-E distances >34 mm, timing accuracy of reconstruction decreases.

[1]  H. Wellens,et al.  Electrical Stimulation of the Heart in Patients with Ventricular Tachycardia , 1972, Circulation.

[2]  A. N. Tikhonov,et al.  Solutions of ill-posed problems , 1977 .

[3]  L. Horowitz,et al.  Recurrent Sustained Ventricular Tachycardia: 1. Mechanisms , 1978, Circulation.

[4]  H. Karagueuzian,et al.  Protracted ventricular tachcardia induced by premature stimulation of the canine heart after coronary artery occlusion and reperfusion. , 1979, Circulation research.

[5]  L. Horowitz,et al.  Role of catheter mapping in the preoperative evaluation of ventricular tachycardia. , 1982, The American journal of cardiology.

[6]  N. El-Sherif,et al.  Reentrant ventricular arrhythmias in the late myocardial infarction period. Interruption of reentrant circuits by cryothermal techniques. , 1983, Circulation.

[7]  B. Taccardi,et al.  A new intracavitary probe for detecting the site of origin of ectopic ventricular beats during one cardiac cycle. , 1987, Circulation.

[8]  Y Rudy,et al.  The inverse problem in electrocardiography: solutions in terms of epicardial potentials. , 1988, Critical reviews in biomedical engineering.

[9]  Y. Rudy,et al.  Regularization of the inverse problem in electrocardiography: A model study , 1988 .

[10]  B. Taccardi,et al.  Localization of ventricular ectopic beats from intracavitary potential distributions: an inverse model in terms of sources , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.

[11]  A. Kadish,et al.  Mechanism‐Specific Therapy of Ventricular Tachycardia , 1990 .

[12]  A. Wilde,et al.  Ventricular tachycardia in the infarcted, Langendorff-perfused human heart: role of the arrangement of surviving cardiac fibers. , 1990, Journal of the American College of Cardiology.

[13]  H Calkins,et al.  Concealed entrainment as a guide for catheter ablation of ventricular tachycardia in patients with prior myocardial infarction. , 1991, Journal of the American College of Cardiology.

[14]  E Downar,et al.  A Three‐Dimensional Display for Cardiac Activation Mapping , 1991, Pacing and clinical electrophysiology : PACE.

[15]  J M Jenkins,et al.  Identification of Ventricular Tachycardia Using Intracardiac Electrograms: A Comparison of Unipolar Versus Bipolar Waveform Analysis , 1991, Pacing and clinical electrophysiology : PACE.

[16]  Y Rudy,et al.  A model study of volume conductor effects on endocardial and intracavitary potentials. , 1992, Circulation research.

[17]  Reconstruction of endocardial potentials from intracavitary probe potentials: a model study , 1992, Proceedings Computers in Cardiology.

[18]  E. Downar,et al.  Mechanisms of spontaneous shift of surface electrocardiographic configuration during ventricular tachycardia. , 1992, Journal of the American College of Cardiology.

[19]  A. Castellanos,et al.  Sudden Cardiac Death: Future Approaches Based on Identification and Control of Transient Risk Factors , 1992 .

[20]  E. Downar,et al.  Late results of operation for ventricular tachycardia. , 1992, The Annals of thoracic surgery.

[21]  J. Langberg,et al.  Radiofrequency Catheter Ablation of Ventricular Tachycardia in Patients With Coronary Artery Disease , 1993, Circulation.

[22]  Philip Sager,et al.  Identification of Reentry Circuit Sites During Catheter Mapping and Radiofrequency Ablation of Ventricular Tachycardia Late After Myocardial Infarction , 1993, Circulation.

[23]  G. Breithardt,et al.  Management of Patients with Ventricular Tachyarrhythmias: Does an Optimal Therapy Exist? , 1994, Pacing and clinical electrophysiology : PACE.

[24]  J M Jenkins,et al.  Digital Signal Processing Chip Implementation for Detection and Analysis of Intracardiac Electrograms , 1994, Pacing and clinical electrophysiology : PACE.

[25]  M. Scheinman Patterns of Catheter Ablation Practice in the United States: Results of the 1992 NASPE Survey , 1994, Pacing and clinical electrophysiology : PACE.

[26]  S. Deshpande,et al.  Catheter ablation of ventricular tachycardia. , 1994, American heart journal.

[27]  S Masse,et al.  Endocardial mapping of ventricular tachycardia in the intact human ventricle. III. Evidence of multiuse reentry with spontaneous and induced block in portions of reentrant path complex. , 1995, Journal of the American College of Cardiology.

[28]  Y. Rudy,et al.  Reconstruction of endocardial potentials and activation sequences from intracavitary probe measurements. Localization of pacing sites and effects of myocardial structure. , 1995, Circulation.

[29]  M. Chiariello,et al.  Role of catheter-induced mechanical trauma in localization of target sites of radiofrequency ablation in automatic atrial tachycardia. , 1996, Journal of the American College of Cardiology.

[30]  L. Gepstein,et al.  A novel method for nonfluoroscopic catheter-based electroanatomical mapping of the heart. In vitro and in vivo accuracy results. , 1997, Circulation.

[31]  P. Bonhoeffer,et al.  Coronary artery obstruction after the arterial switch operation for transposition of the great arteries in newborns. , 1997, Journal of the American College of Cardiology.

[32]  A. Buxton,et al.  Radiofrequency catheter ablation of postinfarction ventricular tachycardia: long-term success and the significance of inducible nonclinical arrhythmias. , 1997, Circulation.

[33]  C. Gornick,et al.  Validation of a new noncontact catheter system for electroanatomic mapping of left ventricular endocardium. , 1999, Circulation.