Development and testing of a compact endoscope manipulator for minimally invasive surgery

Objective: This report describes the design, development, and testing of a novel compact surgical assistant robot to control the orientation and insertion depth of a laparoscopic endoscope during minimally invasive abdominal surgery. In contrast to typical endoscope manipulators, the described robot is particularly compact and lightweight, is simple to set up and use, occupies no floor or operating table space, and does not limit access to the patient in any way. Materials and Methods: The sterilizable endoscope manipulator is sufficiently small and lightweight at 625 g and 110 mm in diameter that it can be placed directly on the abdomen of the patient without interfering with other handheld instruments during minimally invasive surgery. It consists of an annular base, a clamp to hold an endoscope trocar, and two joints which enable azimuth rotation and inclination of the endoscope about a pivot point at the incision. The endoscope insertion depth is controlled by a cable winding acting against a compression spring on the endoscope shaft. Voice recognition and miniature keypad user command interfaces are provided, and the manipulator motors are backdriveable for manual repositioning. Results: Endoscope camera trajectory-following accuracy and response-time results were measured using an optical localizer. Experimental results are given comparing the current prototype with the previous cable-driven prototype. The endoscope manipulator and its user interface were tested and evaluated by several surgeons during a series of minimally invasive surgical training procedures on cadavers and animals. Conclusions: The endoscope manipulator described has been shown to be a viable, practical device with performance and functionality equivalent to those of commercially available models, yet with greatly reduced size, weight, and cost.

[1]  V. L. Nickel,et al.  DEVELOPMENT OF USEFUL FUNCTION IN THE SEVERELY PARALYZED HAND. , 1963, The Journal of bone and joint surgery. American volume.

[2]  Russell H. Taylor,et al.  A telerobotic assistant for laparoscopic surgery , 1995 .

[3]  A W Partin,et al.  Comparison of robotic versus human laparoscopic camera control . , 1995, The Journal of urology.

[4]  P C McAfee,et al.  Robotic arm enhancement to accommodate improved efficiency and decreased resource utilization in complex minimally invasive surgical procedures. , 1996, Studies in health technology and informatics.

[5]  L. Mettler,et al.  One year of experience working with the aid of a robotic assistant (the voice-controlled optic holder AESOP) in gynaecological endoscopic surgery. , 1998, Human reproduction.

[6]  K Masamune,et al.  A new safe laparoscopic manipulator system with a five-bar linkage mechanism and an optical zoom. , 1999, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[7]  G. Buess,et al.  A new remote-controlled endoscope positioning system for endoscopic solo surgery , 2000, Surgical Endoscopy.

[8]  John Kenneth Salisbury,et al.  The Intuitive/sup TM/ telesurgery system: overview and application , 2000, Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065).

[9]  J. Dankelman,et al.  Time-action analysis of instrument positioners in laparoscopic cholecystectomy , 2001, Surgical Endoscopy And Other Interventional Techniques.

[10]  P. Finlay,et al.  Controlled trial of the introduction of a robotic camera assistant (Endo Assist) for laparoscopic cholecystectomy , 2002, Surgical Endoscopy And Other Interventional Techniques.

[11]  Garth H Ballantyne,et al.  Comparison of Laparoscopic Colectomy With and Without the Aid of a Robotic Camera Holder , 2002, Surgical laparoscopy, endoscopy & percutaneous techniques.

[12]  Philippe Cinquin,et al.  Development of a Compact Cable-Driven Laparoscopic Endoscope Manipulator , 2002, MICCAI.

[13]  Philippe Cinquin,et al.  A compact, compliant laparoscopic endoscope manipulator , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[14]  Philippe Cinquin,et al.  LER: the light endoscope robot , 2003, Proceedings 2003 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2003) (Cat. No.03CH37453).

[15]  Jocelyne Troccaz,et al.  FROM THE LABORATORY TO THE OPERATING ROOM: USABILITY TESTING OF LER, THE LIGHT ENDOSCOPE ROBOT , 2004 .