Detachable fiber optic tips for use in thulium fiber laser lithotripsy

Abstract. The thulium fiber laser (TFL) has recently been proposed as an alternative to the Holmium:YAG (Ho:YAG) laser for lithotripsy. The TFL’s Gaussian spatial beam profile provides higher power transmission through smaller optical fibers with reduced proximal fiber tip damage, and improved saline irrigation and flexibility through the ureteroscope. However, distal fiber tip damage may still occur during stone fragmentation, resulting in disposal of the entire fiber after the procedure. A novel design for a short, detachable, distal fiber tip that can fit into an ureteroscope’s working channel is proposed. A prototype, twist-lock, spring-loaded mechanism was constructed using micromachining methods, mating a 150-μm-core trunk fiber to 300-μm-core fiber tip. Optical transmission measuring 80% was observed using a 30-mJ pulse energy and 500-μs pulse duration. Ex vivo human calcium oxalate monohydrate urinary stones were vaporized at an average rate of 187  μg/s using 20-Hz modulated, 50% duty cycle 5 pulse packets. The highest stone ablation rates corresponded to the highest fiber tip degradation, thus providing motivation for use of detachable and disposable distal fiber tips during lithotripsy. The 1-mm outer-diameter prototype also functioned comparable to previously tested tapered fiber tips.

[1]  Gereon Hüttmann,et al.  Temperature dependence of light absorption in water at holmium and thulium laser wavelengths. , 2002, Applied optics.

[2]  Bodo E Knudsen,et al.  Quantification of holmium:yttrium aluminum garnet optical tip degradation. , 2009, Journal of endourology.

[3]  Christopher M. Cilip,et al.  Thulium Fiber Laser Ablation of Urinary Stones Through Small-Core Optical Fibers , 2009, IEEE Journal of Selected Topics in Quantum Electronics.

[4]  Richard J. Timmerman,et al.  Shaped fiber tips for medical and industrial applications , 2004, SPIE BiOS.

[5]  Peter Allen,et al.  A new and improved vitreoretinal erbium:YAG laser scalpel: long-term morphologic characteristics of retinal-choroidal injury. , 2004, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.

[6]  Manoj Monga,et al.  Durability of reusable holmium:YAG laser fibers: a multicenter study. , 2011, The Journal of urology.

[7]  Saher Maswadi,et al.  Performance and safety of holmium: YAG laser optical fibers. , 2005, Journal of endourology.

[8]  Alfred Vogel,et al.  Minimization of Thermomechanical Side Effects in IR Ablation by Use of Multiply Q-Switched Laser Pulses , 2002 .

[9]  K. Levin,et al.  Mid-IR Germanium Oxide Fibers for Contact Erbium Laser Tissue Ablation in Endoscopic Surgery , 2007, IEEE Journal of Selected Topics in Quantum Electronics.

[10]  A J Welch,et al.  Temperature dependence of the absorption coefficient of water for midinfrared laser radiation , 1994, Lasers in surgery and medicine.

[11]  Nathaniel M. Fried,et al.  Thulium fiber laser lithotripsy using tapered fibers , 2010, Lasers in surgery and medicine.

[12]  Bodo E Knudsen,et al.  Holmium:yttrium-aluminum-garnet lithotripsy proximal fiber failures from laser and fiber mismatch. , 2008, Urology.

[13]  A J Welch,et al.  Holmium: YAG lithotripsy: photothermal mechanism. , 1999, Journal of endourology.

[14]  T J Flotte,et al.  Co:MgF2 laser ablation of tissue: Effect of wavelength on ablation threshold and thermal damage , 1991, Lasers in surgery and medicine.

[15]  Nathaniel M Fried,et al.  Thulium fiber laser lithotripsy: An in vitro analysis of stone fragmentation using a modulated 110‐watt Thulium fiber laser at 1.94 µm , 2005, Lasers in surgery and medicine.

[16]  I M Thompson,et al.  Economic impact of urolithiasis in the United States. , 1995, The Journal of urology.

[17]  Nathaniel M Fried,et al.  Enhanced thulium fiber laser lithotripsy using micro-pulse train modulation. , 2012, Journal of biomedical optics.