Direct Torque Control of Five-leg Dual-PMSM Drive Systems for Fault-tolerant Purposes

To enhance the reliability of two-motor drive systems, this paper proposes an improved direct torque control (DTC) scheme (P-DTC) for five-leg dual-PMSM drive systems. First, the topology of a five-leg dual-PMSM drive system is illustrated. To clarify the analysis of the P-DTC, the standard DTC scheme for three-phase drive systems is presented. The operation of a five-leg dual-PMSM drive system is classified into three situations according to the definitions of the switching-vector unions. Compared with the existing DTC scheme (R-DTC), the P-DTC can minimize the replacement of active switching-vectors to zero switching-vectors. When this replacement cannot be avoided, the P-DTC uses a proposed master-slave selection principle to minimize the system error. Comparing with the R-DTC, the P-DTC has lower torque ripples, a wider speed range and a faster torque increasing response. Experiments have been carried out in the coupling and independent modes, and the effectiveness of the P-DTC is verified by the obtained results

[1]  Drazen Dujic,et al.  Five-leg inverter PWM technique for reduced switch count two-motor constant power applications , 2008 .

[2]  Kouki Matsuse,et al.  Improved Method of Voltage Utility Factor for PWM Control Method of Five-Leg Inverter , 2006 .

[3]  Ying Zhu,et al.  A Fault-Tolerant Permanent-Magnet Traction Module for Subway Applications , 2014, IEEE Transactions on Power Electronics.

[4]  Sanghoon Kim,et al.  A Diagnostic Method of Simultaneous Open-Switch Faults in Inverter-Fed Linear Induction Motor Drive for Reliability Enhancement , 2015, IEEE Transactions on Industrial Electronics.

[5]  Marian P. Kazmierkowski,et al.  Direct torque control of PWM inverter-fed AC motors - a survey , 2004, IEEE Transactions on Industrial Electronics.

[6]  Thomas M. Jahns,et al.  Pulsating torque minimization techniques for permanent magnet AC motor drives-a review , 1996, IEEE Trans. Ind. Electron..

[7]  Ming Cheng,et al.  Fault-Tolerant Control of Dual Three-Phase Permanent-Magnet Synchronous Machine Drives Under Open-Phase Faults , 2017, IEEE Transactions on Power Electronics.

[8]  Ahmad Radan,et al.  Novel comparative study between SVM, DTC and DTC-SVM in Five-Leg Inverter to drive two motors independently , 2013, 4th Annual International Power Electronics, Drive Systems and Technologies Conference.

[9]  Yihua Hu,et al.  In Situ Diagnostics and Prognostics of Solder Fatigue in IGBT Modules for Electric Vehicle Drives , 2015, IEEE Transactions on Power Electronics.

[10]  Wei Wang,et al.  A Dual-Level Hysteresis Current Control for One Five-Leg VSI to Control Two PMSMs , 2017, IEEE Transactions on Power Electronics.

[11]  Wooi Ping Hew,et al.  A Comparative Study of Synchronous Current Control Schemes Based on FCS-MPC and PI-PWM for a Two-Motor Three-Phase Drive , 2014, IEEE Transactions on Industrial Electronics.

[12]  Behrooz Mirafzal,et al.  Survey of Fault-Tolerance Techniques for Three-Phase Voltage Source Inverters , 2014, IEEE Transactions on Industrial Electronics.

[13]  Wooi Ping Hew,et al.  Model Predictive Control of a Two-Motor Drive With Five-Leg-Inverter Supply , 2013, IEEE Transactions on Industrial Electronics.

[14]  Philippe Delarue,et al.  Generic control method of multileg voltage-source-converters for fast practical implementation , 2003 .

[15]  Li Sun,et al.  Current Residual Vector-Based Open-Switch Fault Diagnosis of Inverters in PMSM Drive Systems , 2015, IEEE Transactions on Power Electronics.

[16]  Jorge O. Estima,et al.  A fault-tolerant permanent magnet synchronous motor drive with integrated voltage source inverter open-circuit faults diagnosis , 2011, Proceedings of the 2011 14th European Conference on Power Electronics and Applications.

[17]  Liuchen Chang,et al.  Real-Time Diagnosis for Open-Circuited and Unbalance Faults in Electronic Converters Connected to Residential Wind Systems , 2016, IEEE Transactions on Industrial Electronics.

[18]  K. W. Lim,et al.  Analysis of direct torque control in permanent magnet synchronous motor drives , 1997 .

[19]  Jin Zhao,et al.  A Real-Time Multiple Open-Circuit Fault Diagnosis Method in Voltage-Source-Inverter Fed Vector Controlled Drives , 2016, IEEE Transactions on Power Electronics.

[20]  Wei Wang,et al.  Comparison of two different traction systems for subway application using Energetic Macroscopic Representation , 2012, 2012 IEEE Vehicle Power and Propulsion Conference.

[21]  Thomas G. Habetler,et al.  An Open-Switch Fault Diagnosis Method for Single-Phase PWM Rectifier Using a Model-Based Approach in High-Speed Railway Electrical Traction Drive System , 2016, IEEE Transactions on Power Electronics.

[22]  Yong Kang,et al.  Switch Short-Circuit Fault Diagnosis and Remedial Strategy for Full-Bridge DC–DC Converters , 2015, IEEE Transactions on Power Electronics.

[23]  Xuhui Wen,et al.  Adaptive-Linear-Neuron-Based Dead-Time Effects Compensation Scheme for PMSM Drives , 2016, IEEE Transactions on Power Electronics.

[24]  Yong Kang,et al.  Fault Diagnosis of PWM DC–DC Converters Based on Magnetic Component Voltages Equation , 2014, IEEE Transactions on Power Electronics.

[25]  Ching Chuen Chan,et al.  Overview of Permanent-Magnet Brushless Drives for Electric and Hybrid Electric Vehicles , 2008, IEEE Transactions on Industrial Electronics.

[26]  Wei Hua,et al.  Overview of Stator-Permanent Magnet Brushless Machines , 2011, IEEE Transactions on Industrial Electronics.

[27]  Bilal Akin,et al.  A New V/f-Based Sensorless MTPA Control for IPMSM Drives , 2016, IEEE Transactions on Power Electronics.