PMV model is insufficient to capture subjective thermal response from Indians

A controlled laboratory experiment was carried out on forty Indian male college students for evaluating the effect of indoor thermal environment on occupants' response and thermal comfort. During experiment, indoor temperature varied from 21 degrees C to 33 degrees C, and the variables like relative humidity, airflow, air temperature and radiant temperature were recorded along with subject's physiological parameters (skin (T-sk) and oral temperature (T-c)) and subjective thermal sensation responses (TSV). From T-sk and T-c, body temperature (T-b) was evaluated. Subjective Thermal Sensation Vote (TSV) was recorded using ASHRAE 7-point scale. In PMV model, Fanger's T-sk equation was used to accommodate adaptive response. Step-wise regression analysis result showed T-b was better predictor of TSV than T-sk and T-c. Regional skin temperature response, suppressed sweating without dipping, lower sweating threshold temperature and higher cutaneous threshold for sweating were observed as thermal adaptive responses. These adaptive responses cannot be considered in PMV model. To incorporate subjective adaptive response, mean skin temperature (T-sk) is considered in dry heat loss calculation. Along with these, PMV-model and other two methodologies are adopted to calculate PMV values and results are compared. However, recent literature is limited to measure the sweat rate in Indians and consideration of constant Ersw in PMV model needs to be corrected. Using measured T-sk in PMV model (Method(1)), thermal comfort zone corresponding to 0.5 <= PMV <= 0.5 was evaluated as (22.46-25.41) degrees C with neutral temperature of 23.91 degrees C, similarly while using TSV response, wider comfort zone was estimated as (23.25-26.32) degrees C with neutral temperature at 24.83 degrees C, which was further increased to with TSV-PPDnew, relation. It was observed that PMV-model overestimated the actual thermal response. Interestingly, these subjects were found to be less sensitive to hot but more sensitive to cold. A new TSV-PPD relation (PPDnew) was obtained from the population distribution of TSV response with an asymmetric distribution of hot-cold thermal sensation response from Indians. The calculations of human thermal stress according to steady state energy balance models used on PMV model seem to be inadequate to evaluate human thermal sensation of Indians. Relevance to industry: The purpose of this paper is to estimate thermal comfort zone and optimum temperature for Indians. It also highlights that PMV model seems to be inadequate to evaluate subjective thermal perception in Indians. These results can be used in feedback control of HVAC systems in residential and industrial buildings. (C) 2014 Elsevier B.V. All rights reserved.

[1]  F. Mallick Thermal comfort and building design in the tropical climates , 1996 .

[2]  G. Maw,et al.  Forehead skin temperature and thermal sensation during exercise in cool and thermoneutral environments. , 1995, Aviation, space, and environmental medicine.

[3]  W. Höfler Changes in regional distribution of sweating during acclimatization to heat. , 1968, Journal of applied physiology.

[4]  Victor Candas,et al.  Ageing and thermal responses during passive heat exposure: sweating and sensory aspects , 2007, European Journal of Applied Physiology.

[5]  J D Hardy,et al.  Partitional calorimetric studies of man during exposures to thermal transients. , 1966, Journal of applied physiology.

[6]  Chandra Sekhar,et al.  Thermal comfort evaluation of naturally ventilated public housing in Singapore , 2002 .

[7]  George Havenith,et al.  Temperature regulation and technology , 2001 .

[8]  Joo-Young Lee,et al.  Cutaneous thermal thresholds of tropical indigenes residing in Japan , 2011 .

[9]  M. Hancock,et al.  Do people like to feel ‘neutral’?: Exploring the variation of the desired thermal sensation on the ASHRAE scale , 2007 .

[10]  D. DuBois,et al.  A formula to estimate the approximate surface area if height and weight be known , 1989 .

[11]  R. Dear,et al.  Thermal adaptation in the built environment: a literature review , 1998 .

[12]  J D Hardy,et al.  Partitional calorimetric studies of responses of man to thermal transients. , 1966, Journal of applied physiology.

[13]  Youming Chen,et al.  A new approach for measuring predicted mean vote (PMV) and standard effective temperature (SET , 2003 .

[14]  M. J. Patterson,et al.  Humid heat acclimation does not elicit a preferential sweat redistribution toward the limbs. , 2004, American journal of physiology. Regulatory, integrative and comparative physiology.

[15]  Dale Johnson Fundamentals of Aerospace Medicine , 2012 .

[16]  S. N. Garg,et al.  Different glazing systems and their impact on human thermal comfort—Indian scenario , 2008 .

[17]  M. Sawka,et al.  A simple and valid method to determine thermoregulatory sweating threshold and sensitivity. , 2009, Journal of applied physiology.

[18]  Surat Atthajariyakul,et al.  Small fan assisted air conditioner for thermal comfort and energy saving in Thailand , 2008 .

[19]  J. Tsujita,et al.  COMPARATIVE STUDIES ON SWEATING REFLEX, NUMBERS OF ACTIVE SWEAT GLAND AND BODY TEMPERATURE OF SUBTROPICAL NATIVES AND TEMPERATE NATIVES , 1978 .

[20]  Manoj Kumar Singh,et al.  Adaptive thermal comfort model for different climatic zones of North-East India , 2011 .

[21]  D. D. Bois,et al.  CLINICAL CALORIMETRY: TENTH PAPER A FORMULA TO ESTIMATE THE APPROXIMATE SURFACE AREA IF HEIGHT AND WEIGHT BE KNOWN , 1916 .

[22]  Madhavi Indraganti,et al.  Thermal comfort in apartments in India: Adaptive use of environmental controls and hindrances , 2011 .

[23]  J. C. Stevens,et al.  Temperature sensitivity of the body surface over the life span. , 1998, Somatosensory & motor research.

[24]  T. Doherty,et al.  Indoor Environmental Quality ( IEQ ) Title Evaluation of the physiological bases of thermal comfort models , 2006 .

[25]  Chinmei Chou,et al.  Cutaneous Warm and Cool Sensation Thresholds and the Inter-threshold Zone in Malaysian and Japanese Males. , 2010, Journal of thermal biology.

[26]  Gail Brager,et al.  Thermal comfort in naturally ventilated buildings: revisions to ASHRAE Standard 55 , 2002 .

[27]  M. Holmes,et al.  Climate change, thermal comfort and energy: Meeting the design challenges of the 21st century , 2007 .

[28]  M. J. Dauncey,et al.  Influence of mild cold on 24 h energy expenditure, resting metabolism and diet-induced thermogenesis , 1981, British Journal of Nutrition.

[29]  P. O. Fanger,et al.  Thermal comfort: analysis and applications in environmental engineering, , 1972 .

[30]  J. A. J. Stolwijk,et al.  Differential thermal sensitivity in the human skin , 2004, Pflügers Archiv.

[31]  Mi-Young Lee,et al.  The change in peripheral sweating mechanisms of the tropical Malaysian who stays in Japan , 2004 .

[32]  David S. Goldstein,et al.  Relative contribution of core and skin temperatures to thermal comfort in humans , 2000 .

[33]  James D. Hardy,et al.  The technic of measuring radiation and convection , 1938 .

[34]  B. Nielsen,et al.  Influence of skin temperature distribution on thermal sensation in a cool environment , 2004, European Journal of Applied Physiology and Occupational Physiology.

[35]  Junichi Sugenoya,et al.  Preferred ambient temperature for old and young men in summer and winter , 1992, International journal of biometeorology.

[36]  L E Marks,et al.  Regional sensitivity and spatial summation in the warmth sense. , 1974, Physiology & behavior.

[37]  A N Exton-Smith,et al.  Urban hypothermia: preferred temperature and thermal perception in old age. , 1981, British medical journal.

[38]  S Hori,et al.  Adaptation to heat. , 1995, The Japanese journal of physiology.

[39]  Y. Tochihara,et al.  Effects of exercise in the heat on thermoregulation of Japanese and Malaysian males. , 2005, Journal of physiological anthropology and applied human science.

[40]  R. H. Fox,et al.  A study of temperature regulation in New Guinea people. , 1972, Human biology in Oceania.

[41]  E. M. Glaser Acclimatization to heat and cold , 1949, The Journal of physiology.

[42]  Chungyoon Chun,et al.  Research on seasonal indoor thermal environment and residents' control behavior of cooling and heating systems in Korea , 2009 .

[43]  Mtr Jayasinghe,et al.  Thermal comfort temperature range for factory workers in warm humid tropical climates , 2008 .

[44]  R. Kosonen,et al.  Assessment of productivity loss in air-conditioned buildings using PMV index , 2004 .

[45]  R. Yao,et al.  A theoretical adaptive model of thermal comfort – Adaptive Predicted Mean Vote (aPMV) , 2009 .

[46]  Refrigerating ASHRAE handbook of fundamentals , 1967 .

[47]  Jan Hensen,et al.  Thermal comfort in residential buildings: Comfort values and scales for building energy simulation , 2009 .

[48]  C. D. Koh,et al.  Review of thermal comfort design based on PMV/PPD in cabins of Korean maritime patrol vessels , 2007 .

[49]  N. B. Strydom,et al.  HEAT REACTIONS OF CAUCASIANS AND BANTU IN SOUTH AFRICA. , 1964, Journal of applied physiology.

[50]  Mark Standeven,et al.  Thermal comfort for free-running buildings , 1996 .

[51]  N. A. Oseland,et al.  Predicted and reported thermal sensation in climate chambers, offices and homes , 1995 .

[52]  F. Nicol Adaptive thermal comfort standards in the hot–humid tropics , 2004 .

[53]  Madhavi Indraganti Thermal comfort in naturally ventilated apartments in summer: Findings from a field study in Hyderabad, India , 2010 .

[54]  Tzu-Ping Lin,et al.  Thermal perceptions, general adaptation methods and occupant's idea about the trade-off between thermal comfort and energy saving in hot–humid regions , 2009 .

[55]  Alireza Akbarzadeh Tootoonchi,et al.  Controlling automobile thermal comfort using optimized fuzzy controller , 2008 .

[56]  B W Olesen,et al.  International standards and the ergonomics of the thermal environment. , 1995, Applied ergonomics.

[57]  Hui Zhang,et al.  Partial- and whole-body thermal sensation and comfort— Part I: Uniform environmental conditions , 2006 .

[58]  Byron W. Jones Capabilities and limitations of thermal models for use in thermal comfort standards , 2002 .

[59]  N. Taylor,et al.  Preferred room temperature of young vs aged males: the influence of thermal sensation, thermal comfort, and affect. , 1995, The journals of gerontology. Series A, Biological sciences and medical sciences.

[60]  Gail Brager,et al.  Developing an adaptive model of thermal comfort and preference , 1998 .

[61]  Sharafat Ali,et al.  Tropical summer index—a study of thermal comfort of Indian subjects , 1986 .

[62]  C. H. Wyndham,et al.  A physiological scheme and mathematical model of temperature regulation in man , 2004, Pflügers Archiv.

[63]  Effect of skin temperature on the cholinergic sensitivity of the human eccrine sweat gland. , 2003 .

[64]  M. Motomura,et al.  Study on Mechanisms of Heat Acclimatization Due to Thermal Sweating : Comparison of Heat-tolerance between Japanese and Thai Subjects , 1993 .

[65]  Y. Min,et al.  Tropical Malaysians and temperate Koreans exhibit significant differences in sweating sensitivity in response to iontophoretically administered acetylcholine , 2009, International journal of biometeorology.

[66]  J. F. Nicol,et al.  The validity of ISO-PMV for predicting comfort votes in every-day thermal environments , 2002 .