Fast and robust 3D T1 mapping using spiral encoding and steady RF excitation at 7 T: application to cardiac manganese enhanced MRI (MEMRI) in mice

Mapping longitudinal relaxation times in 3D is a promising quantitative and non‐invasive imaging tool to assess cardiac remodeling. Few methods are proposed in the literature allowing us to perform 3D T1 mapping. These methods often require long scan times and use a low number of 3D images to calculate T1. In this project, a fast 3D T1 mapping method using a stack‐of‐spirals sampling scheme and regular RF pulse excitation at 7 T is presented. This sequence, combined with a newly developed fitting procedure, allowed us to quantify T1 of the whole mouse heart with a high spatial resolution of 208 × 208 × 315 µm3 in 10–12 min acquisition time. The sensitivity of this method for measuring T1 variations was demonstrated on mouse hearts after several injections of manganese chloride (doses from 25 to 150 µmol kg−1). T1 values were measured in vivo in both pre‐ and post‐contrast experiments. This protocol was also validated on ischemic mice to demonstrate its efficiency to visualize tissue damage induced by a myocardial infarction. This study showed that combining spiral gradient shape and steady RF excitation enabled fast and robust 3D T1 mapping of the entire heart with a high spatial resolution. Copyright © 2015 John Wiley & Sons, Ltd.

[1]  David M Higgins,et al.  Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart , 2004, Magnetic resonance in medicine.

[2]  R Deichmann,et al.  Quantification of T1 values by SNAPSHOT-FLASH NMR imaging , 1992 .

[3]  Mark Griswold,et al.  Fast cardiac T1 mapping in mice using a model‐based compressed sensing method , 2012, Magnetic resonance in medicine.

[4]  Klaas Nicolay,et al.  Three‐dimensional T1 mapping of the mouse heart using variable flip angle steady‐state MR imaging , 2011, NMR in biomedicine.

[5]  W. Bao,et al.  Simultaneous assessment of left‐ventricular infarction size, function and tissue viability in a murine model of myocardial infarction by cardiac manganese‐enhanced magnetic resonance imaging (MEMRI) , 2004, NMR in biomedicine.

[6]  Bénédicte M A Delattre,et al.  Myocardial infarction quantification with Manganese‐Enhanced MRI (MEMRI) in mice using a 3T clinical scanner , 2010, NMR in biomedicine.

[7]  K. Chuang,et al.  Relationship between blood and myocardium manganese levels during manganese‐enhanced MRI (MEMRI) with T1 mapping in rats , 2011, NMR in biomedicine.

[8]  Scott T. Acton,et al.  Three‐dimensional phase contrast angiography of the mouse aortic arch using spiral MRI , 2011, Magnetic resonance in medicine.

[9]  L. Begnozzi,et al.  Multiple 3D inversion recovery imaging for volume T1 mapping of the heart , 2013, Magnetic resonance in medicine.

[10]  Craig H Meyer,et al.  Improved arterial spin labeling after myocardial infarction in mice using cardiac and respiratory gated look‐locker imaging with fuzzy C‐means clustering , 2010, Magnetic resonance in medicine.

[11]  J. Franconi,et al.  A fast black‐blood sequence for four‐dimensional cardiac manganese‐enhanced MRI in mouse , 2011, NMR in biomedicine.

[12]  Biplab Das,et al.  Collagen-targeted MRI contrast agent for molecular imaging of fibrosis. , 2007, Angewandte Chemie.

[13]  Patrick A Helm,et al.  Postinfarction myocardial scarring in mice: molecular MR imaging with use of a collagen-targeting contrast agent. , 2008, Radiology.

[14]  Dwight G. Nishimura,et al.  Rapid gridding reconstruction with a minimal oversampling ratio , 2005, IEEE Transactions on Medical Imaging.

[15]  Mehmet Akçakaya,et al.  Free‐breathing post‐contrast three‐dimensional T1 mapping: Volumetric assessment of myocardial T1 values , 2014, Magnetic resonance in medicine.

[16]  Mark Griswold,et al.  Rapid T1 mapping of mouse myocardium with saturation recovery look‐locker method , 2010, Magnetic resonance in medicine.

[17]  O. Simonetti,et al.  An improved MR imaging technique for the visualization of myocardial infarction. , 2001, Radiology.

[18]  Mehmet Akcakaya,et al.  Heart-rate independent myocardial T1-mapping using combined saturation and inversion preparation pulses , 2013, Journal of Cardiovascular Magnetic Resonance.

[19]  Dara L Kraitchman,et al.  Cardiac magnetic resonance imaging in small rodents using clinical 1.5 T and 3.0 T scanners. , 2007, Methods.

[20]  R. Kim,et al.  Performance of Delayed-Enhancement Magnetic Resonance Imaging With Gadoversetamide Contrast for the Detection and Assessment of Myocardial Infarction: An International, Multicenter, Double-Blinded, Randomized Trial , 2008, Circulation.

[21]  K. Nicolay,et al.  Contrast‐enhanced MRI of murine myocardial infarction – Part I , 2012, NMR in biomedicine.

[22]  Johan Kihlberg,et al.  Rapid T1 quantification based on 3D phase sensitive inversion recovery , 2010, BMC Medical Imaging.

[23]  Richard B Thompson,et al.  Saturation recovery single‐shot acquisition (SASHA) for myocardial T1 mapping , 2014, Magnetic resonance in medicine.

[24]  P Mansfield,et al.  Optimization of the ultrafast Look-Locker echo-planar imaging T1 mapping sequence. , 1998, Magnetic resonance imaging.

[25]  B. Cowan,et al.  Journal of Cardiovascular Magnetic Resonance Open Access Aortic Valve Stenotic Area Calculation from Phase Contrast Cardiovascular Magnetic Resonance: the Importance of Short Echo Time , 2009 .

[26]  Laurent Lamalle,et al.  Improved k‐space trajectory measurement with signal shifting , 2007, Magnetic resonance in medicine.

[27]  Christine L. Tardif,et al.  On the accuracy of T1 mapping: Searching for common ground , 2015, Magnetic resonance in medicine.

[28]  P. Kellman,et al.  T1-mapping in the heart: accuracy and precision , 2014, Journal of Cardiovascular Magnetic Resonance.

[29]  E. McVeigh,et al.  Phase‐sensitive inversion recovery for detecting myocardial infarction using gadolinium‐delayed hyperenhancement † , 2002, Magnetic resonance in medicine.

[30]  D. Look,et al.  Time Saving in Measurement of NMR and EPR Relaxation Times , 1970 .

[31]  Kai-Hsiang Chuang,et al.  Monitoring dynamic alterations in calcium homeostasis by T 1‐weighted and T 1‐mapping cardiac manganese‐enhanced MRI in a murine myocardial infarction model , 2008, NMR in biomedicine.

[32]  B. Delattre,et al.  Manganese kinetics demonstrated double contrast in acute but not in chronic infarction in a mouse model of myocardial occlusion reperfusion , 2012, NMR in biomedicine.

[33]  Andreas Sigfridsson,et al.  Four‐dimensional flow MRI using spiral acquisition , 2012, Magnetic resonance in medicine.

[34]  Richard B. Thompson,et al.  Accuracy, precision, and reproducibility of four T1 mapping sequences: a head-to-head comparison of MOLLI, ShMOLLI, SASHA, and SAPPHIRE. , 2014, Radiology.

[35]  P L Carson,et al.  Determination of sample time for T1 measurement , 1998, Journal of magnetic resonance imaging : JMRI.

[36]  Stefan Neubauer,et al.  Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold , 2010, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[37]  Autumn M. Schumacher,et al.  Assessing manganese efflux using SEA0400 and cardiac T1‐mapping manganese‐enhanced MRI in a murine model , 2009, NMR in biomedicine.