Transversely Excited Multipass Photoacoustic Cell Using Electromechanical Film as Microphone

A novel multipass photoacoustic cell with five stacked electromechanical films as a microphone has been constructed, tested and characterized. The photoacoustic cell is an open rectangular structure with two steel plates facing each other. The longitudinal acoustic resonances are excited transversely in an optical multipass configuration. A detection limit of 22 ppb (10−9) was achieved for flowing NO2 in N2 at normal pressure by using the maximum of 70 laser beams between the resonator plates. The corresponding minimum detectable absorption and the normalized noise-equivalent absorption coefficients were 2.2 × 10−7 cm−1 and 3.2 × 10−9 cm−1WHz−1/2, respectively.

[1]  Gang Li,et al.  The HITRAN 2008 molecular spectroscopic database , 2005 .

[2]  K. Roth,et al.  Cantilever enhanced photoacoustic detection of carbon dioxide using a tunable diode laser source , 2007 .

[3]  B. B. Bauer,et al.  Fundamentals of acoustics , 1963 .

[4]  L. Voesenek,et al.  Sensitive intracavity photoacoustic measurements with a CO2 waveguide laser , 1990 .

[5]  A. Miklós,et al.  Application of acoustic resonators in photoacoustic trace gas analysis and metrology , 2001 .

[6]  C. Hornberger,et al.  Sensitive photoacoustic overtone spectroscopy of acetylene with a multipass photoacoustic cell and a colour centre laser at 1.5 μm , 1995 .

[7]  J. Kauppinen,et al.  Fourier Transforms in Spectroscopy , 2001 .

[8]  M. Sigrist,et al.  Modulated resonant versus pulsed resonant photoacoustics in trace gas detection , 2009 .

[9]  N. Ioli,et al.  A simple transversely excited spectrophone , 1979 .

[10]  Multipass acoustically open photoacoustic detector for trace gas measurements. , 2006, Applied optics.

[11]  Guo-Rong Wu,et al.  Cylindrical mirror multipass Lissajous system for laser photoacoustic spectroscopy , 2002 .

[12]  Michael E Webber,et al.  Fiber-amplifier-enhanced photoacoustic spectroscopy with near-infrared tunable diode lasers. , 2003, Applied optics.

[13]  Markus W. Sigrist,et al.  Investigation and optimisation of a multipass resonant photoacoustic cell at high absorption levels , 2005 .

[14]  V. Koskinen,et al.  Progress in cantilever enhanced photoacoustic spectroscopy , 2008 .

[15]  Jukka Lekkala,et al.  ElectroMechanical Film (EMFi) — a new multipurpose electret material , 2000 .

[16]  H. Saunders,et al.  Fundamentals of Acoustics (3rd Ed.) , 1983 .

[17]  J. Hackstein,et al.  Intracavity CO laser photoacoustic trace gas detection: cyclic CH(4), H(2)O and CO(2) emission by cockroaches and scarab beetles. , 1996, Applied optics.

[18]  Albert Manninen,et al.  Electromechanical film as a photoacoustic transducer. , 2009, Optics express.

[19]  Anton Erhard,et al.  Ferroelectret non-contact ultrasonic transducers , 2007 .

[20]  S. Schilt,et al.  Novel Helmholtz-based photoacoustic sensor for trace gas detection at ppm level using GaInAsSb/GaAlAsSb DFB lasers. , 2006, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[21]  M. Fraser,et al.  Application of quantum cascade lasers to trace gas analysis , 2008 .

[22]  N. Dam,et al.  A multipass transverse photoacoustic cell , 1985 .

[23]  R. Gerlach,et al.  Brewster window and windowless resonant spectrophones for intracavity operation , 1980 .

[24]  Gerard Wysocki,et al.  QEPAS based detection of broadband absorbing molecules using a widely tunable, cw quantum cascade laser at 8.4 mum. , 2007, Optics express.

[25]  Markus W. Sigrist,et al.  Mobile laser spectrometer with novel resonant multipass photoacoustic cell for trace-gas sensing , 2000 .

[26]  Gerhard M. Sessler,et al.  High-sensitivity piezoelectric microphones based on stacked cellular polymer films (L) , 2004 .