Lifecycle CO2 Reduction by Implementing Double Window Casement Systems in Residential Units in Korea

This study investigated lifecycle CO 2 (LCCO 2 ) emission reductions through application of double-window casement systems (DWCS) in residential units in Korea, compared with conventional single windows (SWs). The DWCS is a double window system that is energy-efficient, reducing energy consumption during operation. However, this system incorporates increased embodied CO 2 emissions. We evaluated LCCO 2 reductions associated with use of the DWCS by calculating CO 2 emissions during space conditioning as well as the embodied CO 2 emissions of the DWCS. The results showed that use of DWCS in a residential unit during the cooling season had 26.2 and 27.4 t CO 2 fewer emissions than SWs in the natural ventilation and minimum ventilation modes, respectively. Although implementation of DWCS is expected to substantially reduce LCCO 2 emissions, the large embodied CO 2 emissions of the aluminum frame reduce the benefits of the DWCS.

[1]  Michele De Carli,et al.  Possibilities and limitations of natural ventilation in restored industrial archaeology buildings with a double-skin façade in Mediterranean climates , 2005 .

[2]  M. Sivrioglu,et al.  An experimental study on air window collector having a vertical blind for active solar heating , 1996 .

[3]  조균형,et al.  전과정 평가에 의한 공동주택의 에너지 소비량 평가연구 ( A Study on the Appraisal of Energy Consumption of Apartment Building by LCA Methodology ) , 2002 .

[4]  Toshio Ojima,et al.  Field experiments on natural energy utilization in a residential house with a double skin façade system , 2007 .

[5]  Jorge S. Carlos,et al.  Evaluation of the thermal performance indices of a ventilated double window through experimental and analytical procedures: Uw-values , 2014 .

[6]  Marlon Leão,et al.  Empirical thermal comfort evaluation of single and double skin façades , 2010 .

[7]  N. Hamza Double versus single skin facades in hot arid areas , 2008 .

[8]  Seung-Bok Leigh,et al.  Double window system with ventilation slits to prevent window surface condensation in residential bu , 2011 .

[9]  Juan Zhou,et al.  A REVIEW ON APPLYING VENTILATED DOUBLE-SKIN FACADE TO BUILDINGS IN HOT-SUMMER AND COLD-WINTER ZONE IN CHINA , 2010 .

[10]  Jorge S. Carlos,et al.  Heat recovery versus solar collection in a ventilated double window , 2012 .

[11]  Qingyan Chen,et al.  A computational method for calculating heat transfer and airflow through a dual-airflow window , 2008 .

[12]  André De Herde,et al.  Natural cooling strategies efficiency in an office building with a double-skin facade , 2004 .

[13]  D. Naylor,et al.  Experimental study of free convection in a window with a heated between-panes blind , 2011 .

[14]  Seungjun Roh,et al.  The development of apartment house life cycle CO2 simple assessment system using standard apartment houses of South Korea , 2011 .

[15]  Dirk Saelens,et al.  On the influence of the inlet temperature in multiple-skin facade modeling , 2003 .

[16]  P. Baker,et al.  Test cell analysis of the use of a supply air window as a passive solar component , 2000 .

[17]  Georgios Kokogiannakis,et al.  History and development of validation with the ESP-r simulation program , 2008 .

[18]  Nader Sadegh,et al.  Real-time optimization of a double-skin facade based on lumped modeling and occupant preference , 2004 .

[19]  S. O. Hanssen,et al.  Building simulation as an assisting tool in decision making: Case study: With or without a double-skin façade? , 2008 .

[20]  Fariborz Haghighat,et al.  Energy performance assessment of double-skin façade with thermal mass , 2010 .

[21]  Seung-Bok Leigh,et al.  Indoor Air Flow Pattern in the Mixed-Use Apartment with Double Window System , 2013 .

[22]  Jianing Zhao,et al.  Energy performance of a dual airflow window under different climates , 2010 .

[23]  Zerrin Yilmaz,et al.  Double skin façade's effects on heat losses of office buildings in Istanbul , 2005 .

[24]  Wonjun Choi,et al.  Load characteristics and operation strategies of building integrated with multi-story double skin facade , 2013 .

[25]  Masud Behnia,et al.  A new type of double-skin façade configuration for the hot and humid climate , 2008 .

[26]  Carol A Boyle,et al.  Comparison of life cycle carbon dioxide emissions and embodied energy in four renewable electricity generation technologies in New Zealand. , 2009, Environmental science & technology.

[27]  Jorge S. Carlos,et al.  Ventilated Double Window for the Preheating of the Ventilation Air Comparison of Its Performance in a Northern and a Southern European Climate , 2013 .

[28]  E. Gratia,et al.  Guidelines for improving natural daytime ventilation in an office building with a double-skin facade , 2007 .

[29]  Paul Strachan ESP-r : Summary of Validation Studies , 2000 .

[30]  S. Svendsen,et al.  Experimental analysis of energy performance f a ventilated window for heat recovery under controlled , 2011 .