Agreement between point-of-care glucometry, blood gas and laboratory-based measurement of glucose in an equine neonatal intensive care unit

Objective: To test the agreement between 3 common methods of glucose measurement in a population of critically ill foals presenting to a neonatal intensive care unit. Design: Prospective clinical study. Setting: University large animal hospital neonatal intensive care unit. Animals: Sequentially admitted critically ill neonatal foals <30 days of age. Interventions: Venous blood obtained from a jugular vein was used for determination of blood glucose concentration using point-of-care (POC) glucometry (GLU), a laboratory chemistry technique (CHEM) and a multi-electrode blood gas analyzer (BG). Paired data were compared using Lin's concordance correlation, Pearson's correlation and robust regression. Bias and limits of agreement were investigated using the technique of Bland and Altman. Measurements and main results: Concordance was significant for all comparisons and was strongest for CHEM-BG while weakest for GLU-BG. Pearson's correlation was excellent for all comparisons: CHEM-BG, 0.98; GLU-BG, 0.94; GLU-CHEM, 0.96. All comparisons had significant robust regression coefficients: CHEM-BG, 0.99; GLU-BG, 0.80; GLU-CHEM, 0.79. For Bland–Altman analysis, mean differences (mean±SD, 95% limits of agreement) were: GLU-BG (−33±18 mg/dL, −68.6 to 1.5); GLU-CHEM (−20±16 mg/dL, −51.0 to 10.9); CHEM-BG (13±11 mg/dL, −8.7 to 34.7). Conclusions: This study demonstrates that glucometry has less than ideal agreement with a laboratory standard and another POC test, blood gas analysis. These differences may be clinically important and decisions regarding management of glucose concentrations in critically ill foals should be made with these differences in mind.

[1]  G J Kost,et al.  Effects of different hematocrit levels on glucose measurements with handheld meters for point-of-care testing. , 2009, Archives of pathology & laboratory medicine.

[2]  Hubert W Vesper,et al.  Variability among five over-the-counter blood glucose monitors. , 2006, Clinica chimica acta; international journal of clinical chemistry.

[3]  Brian Hutton,et al.  Reliability of point-of-care testing for glucose measurement in critically ill adults* , 2005, Critical care medicine.

[4]  G. Chrousos,et al.  How accurate are currently used methods of determining glycemia in critically ill patients, and do they affect their clinical course? , 2005, Critical care medicine.

[5]  Sverre Sandberg,et al.  Between-lot variation in external quality assessment of glucose: clinical importance and effect on participant performance evaluation. , 2005, Clinical chemistry.

[6]  B. Afessa,et al.  Agreement between bedside blood and plasma glucose measurement in the ICU setting. , 2005, Chest.

[7]  I. Brandslund,et al.  Measurement of glucose content in plasma from capillary blood in diagnosis of diabetes mellitus , 2003, Scandinavian journal of clinical and laboratory investigation.

[8]  W. Wosniok,et al.  Comparison of Several Point-of-Care Testing (POCT) Glucometers with an Established Laboratory Procedure for the Diagnosis of Type 2 Diabetes Using the Discordance Rate. A New Statistical Approach , 2003, Clinical chemistry and laboratory medicine.

[9]  A. Sirkin,et al.  Selecting an accurate point-of-care testing system: clinical and technical issues and implications in neonatal blood glucose monitoring. , 2002, Journal for specialists in pediatric nursing : JSPN.

[10]  G. V. Berghe,et al.  Intensive insulin therapy in critically ill patients. , 2001, The New England journal of medicine.

[11]  J G Ray,et al.  Pilot study of the accuracy of bedside glucometry in the intensive care unit , 2001, Critical care medicine.

[12]  G J Kost,et al.  Oxygen effects on glucose meter measurements with glucose dehydrogenase- and oxidase-based test strips for point-of-care testing , 2001, Critical care medicine.

[13]  G J Kost,et al.  Point-of-care glucose testing: effects of critical care variables, influence of reference instruments, and a modular glucose meter design. , 2000, Archives of pathology & laboratory medicine.

[14]  N. Sharief,et al.  The inaccuracy of venous and capillary blood glucose measurement using reagent strips in the newborn period and the effect of haematocrit. , 2000, Early human development.

[15]  G J Kost,et al.  Multicenter study of oxygen-insensitive handheld glucose point-of-care testing in critical care/hospital/ambulatory patients in the United States and Canada. , 1998, Critical care medicine.

[16]  J. L. Dirks Diagnostic blood analysis using point-of-care technology. , 1996, AACN clinical issues.

[17]  R. Maser,et al.  Use of arterial blood with bedside glucose reflectance meters in an intensive care unit: Are they accurate? , 1994, Critical care medicine.

[18]  E. Kilpatrick,et al.  The Effect of Variations in Haematocrit, Mean Cell Volume and Red Blood Cell Count on Reagent Strip Tests for Glucose , 1993, Annals of clinical biochemistry.

[19]  L. Lin,et al.  A concordance correlation coefficient to evaluate reproducibility. , 1989, Biometrics.

[20]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[21]  J P Osborne,et al.  Effect of packed cell volume on blood glucose estimations. , 1981, Archives of disease in childhood.

[22]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[23]  P. J. Huber Robust Estimation of a Location Parameter , 1964 .

[24]  G. Price,et al.  Analysis of blood glucose measurements using capillary and arterial blood samples in intensive care patients , 2004, Intensive Care Medicine.

[25]  D. Altman,et al.  A note on the use of the intraclass correlation coefficient in the evaluation of agreement between two methods of measurement. , 1990, Computers in biology and medicine.