ABSTRACT Phoenix Services, Inc., owns and operates the Baltimore Regional Medical Waste Incinerator in Baltimore, MD. New regulations for dioxins and furans imposed a limit that was considerably below historical emission levels. To determine a method to comply with the new dioxin/furan regulations, Phoenix Services performed trials with powdered activated carbon (PAC). Although the results with carbon were acceptable, Phoenix Services decided to replace their woven fiberglass filter bags with catalytic filters that simultaneously destroy dioxins and furans and collect particulate matter (PM). The catalytic filter system offered several advantages to Phoenix Services, including destruction of dioxins and furans instead of adsorption on carbon. The catalytic filters also offered a passive solution that did not require new carbon injection equipment. In January 2000, a campaign to measure dioxins/furans and PM was undertaken.