Hydroxyapatite Composite Resin Cement Augmentation of Pedicle Screw Fixation

Pedicle screw stability is poor in osteopenic vertebrae attributable, in part, to low screw-bone interface strength. The current authors examined cement augmentation using a low curing temperature hydroxyapatite and bis-phenol-A glycidol methacrylate-based composite resin. This cement may stiffen the screw-bone interface and reduce the harmful effects associated with polymethylmethacrylate regarding temperature and toxic monomer. Thirty-five lumbar vertebrae from human cadavers were instrumented with pedicle screws, with one pedicle previously injected with cement and the other as the control. Caudocephalad toggling of ± 1 mm for 1600 cycles was applied to the pedicle screws, and the resulting forces supported by the implant-bone interface were captured by a load cell. A curve was constructed from the peak caudal load for each cycle and three mechanical measures parameterized this curve: (1) initial load; (2) rate of load decay during the first 400 cycles; and (3) final load. The initial load increased by 16% as a result of cement augmentation, the final load increased by 65%, and the rate of load decay decreased by 59%. Cement augmentation of pedicle screws increased the stiffness and stability of the screw-bone interface.

[1]  J. Leong,et al.  The effects of cyclic loading on pull-out strength of sacral screw fixation: an in vitro biomechanical study. , 2000, Spine.

[2]  K. Okuyama,et al.  Can insertional torque predict screw loosening and related failures? An in vivo study of pedicle screw fixation augmenting posterior lumbar interbody fusion. , 2000, Spine.

[3]  G. Bergmann,et al.  Changes in the loads on an internal spinal fixator after iliac-crest autograft. , 2000, The Journal of bone and joint surgery. British volume.

[4]  L. Nolte,et al.  Load-Sharing Characteristics of Stabilized Lumbar Spine Segments , 2000, Spine.

[5]  S. Yerby,et al.  Revision of Failed Pedicle Screws Using Hydroxyapatite Cement: A Biomechanical Analysis , 1998, Spine.

[6]  R. Wittenberg Point of View: Moments and Forces During Pedicle Screw Insertion: In Vitro and In Vivo Measurements , 1998 .

[7]  J A Planell,et al.  Osteotransductive bone cements , 1998, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[8]  D. W. Bühler,et al.  Moments and Forces During Pedicle Screw Insertion: In Vitro and In Vivo Measurements , 1998, Spine.

[9]  J. Lotz,et al.  Carbonated Apatite Cement Augmentation of Pedicle Screw Fixation in the Lumbar Spine , 1997, Spine.

[10]  T. Washio,et al.  Structural Characteristics of the Pedicle and Its Role in Screw Stability , 1997, Spine.

[11]  A Rohlmann,et al.  Comparison of loads on internal spinal fixation devices measured in vitro and in vivo. , 1997, Medical engineering & physics.

[12]  D. Moore,et al.  Restoration of Pedicle Screw Fixation With an in Situ Setting Calcium Phosphate Cement , 1997, Spine.

[13]  Tait S. Smith,et al.  The Effect of Bone Quality on Pedicle Screw Loading in Axial Instability: A Synthetic Model , 1997, Spine.

[14]  T. Washio,et al.  An Experimental Study of a Combination Method Using a Pedicle Screw and Laminar Hook for the Osteoporotic Spine , 1997, Spine.

[15]  S. Yerby,et al.  The effect of pedicle morphometry on pedicle screw loading. A synthetic model. , 1997, Spine.

[16]  T C Hearn,et al.  Insertional Torque and Pull‐out Strengths of Conical and Cylindrical Pedicle Screws in Cadaveric Bone , 1996, Spine.

[17]  B. Myers,et al.  The Role of Imaging and In Situ Biomechanical Testing in Assessing Pedicle Screw Pull‐Out Strength , 1996, Spine.

[18]  A. Vaccaro,et al.  Internal Fixation (Pedicle Screw Fixation) for Fusions of the Lumbar Spine , 1995, Spine.

[19]  S. Cook,et al.  Effects of Bone Mineral Density on Pedicle Screw Fixation , 1994, Spine.

[20]  N. Sugano,et al.  Experimental studies on a new bioactive bone cement: hydroxyapatite composite resin. , 1994, Biomaterials.

[21]  A. Tencer,et al.  Caudo-cephalad loading of pedicle screws: mechanisms of loosening and methods of augmentation. , 1993, Spine.

[22]  W. Hayes,et al.  Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength. , 1993, Clinical orthopaedics and related research.

[23]  D N Kunz,et al.  Pedicle Screw Pullout Strength: Correlation with Insertional Torque , 1993, Spine.

[24]  J N Weinstein,et al.  Anatomic and technical considerations of pedicle screw fixation. , 1992, Clinical orthopaedics and related research.

[25]  T. Tamaki,et al.  Mechanical Stability of the Pedicle Screw Fixation Systems for the Lumbar Spine , 1992, Spine.

[26]  W. Edwards Biomechanics of Posterior Lumbar Fixation: Analysis of Testing Methodologies , 1991, Spine.

[27]  D. E. Swartz,et al.  Importance of bone mineral density in instrumented spine fusions. , 1991, Spine.

[28]  M. Krag Biomechanics of Thoracolumbar Spinal Fixation: A Review , 1991, Spine.

[29]  M H Krag,et al.  Morphometry of the Thoracic and Lumbar Spine Related to Transpedicular Screw Placement for Surgical Spinal Fixation , 1988, Spine.

[30]  B. T. Field,et al.  A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. , 1986, Clinical orthopaedics and related research.

[31]  J W Frymoyer,et al.  An internal fixator for posterior application to short segments of the thoracic, lumbar, or lumbosacral spine. Design and testing. , 1986, Clinical orthopaedics and related research.