Simultaneous ultrasound assessment of brachial artery shear stimulus and flow-mediated dilation during reactive hyperemia.

In flow-mediated dilation (FMD) studies, brachial artery diameter changes due to reactive hyperaemia are typically measured through manual or automatic analysis of high resolution B-mode images while the stimulus of diameter change, i.e., the flow change, is qualitatively estimated by measuring the mean velocity in the vessel and assuming a parabolic velocity profile. This article describes an experimental approach to simultaneously measure the wall shear rate (WSR) and the diameter variations, through multigate spectral Doppler and B-mode image processing, respectively. By using an ultrasound advanced open platform (ULA-OP), experimental results from the brachial arteries of 15 presumed healthy volunteers have been obtained. The mean increments during reflow against baseline were 105% ± 22% for the peak WSR and 8% ± 3% for the FMD. The mean time interval between the WSR peak and the beginning of plateau of diameter waveform was 38 ± 8 s. The results confirm that in young healthy subjects the postischemic vasodilation of brachial artery is largely correlated to the WSR increase.

[1]  D. Thijssen,et al.  Is the ratio of flow-mediated dilation and shear rate a statistically sound approach to normalization in cross-sectional studies on endothelial function? , 2009, Journal of applied physiology.

[2]  K. Pyke,et al.  Are the dynamic response characteristics of brachial artery flow-mediated dilation sensitive to the magnitude of increase in shear stimulus? , 2008, Journal of applied physiology.

[3]  R. Reneman,et al.  An integrated system for the non-invasive assessment of vessel wall and hemodynamic properties of large arteries by means of ultrasound. , 1999, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.

[4]  A. Gnasso,et al.  Association between intima-media thickness and wall shear stress in common carotid arteries in healthy male subjects. , 1996, Circulation.

[5]  L. Ghiadoni,et al.  Effect of acute blood pressure reduction on endothelial function in the brachial artery of patients with essential hypertension , 2001, Journal of hypertension.

[6]  D. Bluemke,et al.  Arterial reactivity in lower extremities is progressively reduced as cardiovascular risk factors increase: comparison with upper extremities using magnetic resonance imaging. , 2007, Journal of the American College of Cardiology.

[7]  D. Wray,et al.  Evidence of preserved endothelial function and vascular plasticity with age. , 2006, American journal of physiology. Heart and circulatory physiology.

[8]  J. Viikari,et al.  Constantly low HDL-cholesterol concentration relates to endothelial dysfunction and increased in vivo LDL-oxidation in healthy young men. , 1999, Atherosclerosis.

[9]  D. Celermajer,et al.  Cigarette Smoking Is Associated With Dose‐Related and Potentially Reversible Impairment of Endothelium‐Dependent Dilation in Healthy Young Adults , 1993, Circulation.

[10]  P. Tortoli,et al.  Improved blood velocity estimation using the maximum Doppler frequency. , 1995, Ultrasound in medicine & biology.

[11]  Sheng Ping Wu,et al.  Wall shear rates differ between the normal carotid, femoral, and brachial arteries: An in vivo MRI study , 2004, Journal of magnetic resonance imaging : JMRI.

[12]  F. Hsu,et al.  Brachial Flow-Mediated Dilation Predicts Incident Cardiovascular Events in Older Adults: The Cardiovascular Health Study , 2007, Circulation.

[13]  J. A. Evans,et al.  The Detection of Early Atherosclerosis in Healthy Male Relatives of Men with Peripheral Arterial Disease: a Feasibility Study , 2009 .

[14]  Amir Lerman,et al.  Endothelial Dysfunction: A Marker of Atherosclerotic Risk , 2003, Arteriosclerosis, thrombosis, and vascular biology.

[15]  Å. Ahlgren,et al.  A method for arterial diameter change measurements using ultrasonic B-mode data. , 2010, Ultrasound in medicine & biology.

[16]  Marcello Demi,et al.  A System for Real-Time Measurement of the Brachial Artery Diameter in B-Mode Ultrasound Images , 2007, IEEE Transactions on Medical Imaging.

[17]  A. Kelly,et al.  Comparison of B-mode and echo tracking methods of assessing flow-mediated dilation. , 2004, Ultrasound in medicine & biology.

[18]  P. Stein,et al.  Errors in the estimation of arterial wall shear rates that result from curve fitting of velocity profiles. , 1993, Journal of biomechanics.

[19]  R. Hughson,et al.  Flow-mediated dilation in human brachial artery after different circulatory occlusion conditions. , 2004, American journal of physiology. Heart and circulatory physiology.

[20]  P. Tortoli,et al.  Noninvasive simultaneous assessment of wall shear rate and wall distension in carotid arteries. , 2006, Ultrasound in medicine & biology.

[21]  K. Pyke,et al.  Impact of controlling shear rate on flow-mediated dilation responses in the brachial artery of humans. , 2004, Journal of applied physiology.

[22]  R. Cobbold,et al.  Comparison of four digital maximum frequency estimators for Doppler ultrasound. , 1988, Ultrasound in medicine & biology.

[23]  P Tortoli,et al.  An FFT-based flow profiler for high-resolution in vivo investigations. , 1997, Ultrasound in medicine & biology.

[24]  A. Gnasso,et al.  Association between wall shear stress and flow-mediated vasodilation in healthy men. , 2001, Atherosclerosis.

[25]  H Ermert,et al.  Real-time Detection of Vessel Diameters with Ultrasound. Echtzeiterkennung von Gefäßdurchmessern mit Ultraschall , 2003, Biomedizinische Technik. Biomedical engineering.

[26]  Theo Arts,et al.  Wall Shear Stress – an Important Determinant of Endothelial Cell Function and Structure – in the Arterial System in vivo , 2006, Journal of Vascular Research.

[27]  Ryan A. Harris,et al.  Assessment of flow-mediated dilation in humans: a methodological and physiological guideline. , 2011, American journal of physiology. Heart and circulatory physiology.

[28]  Marcello Demi,et al.  The First Absolute Central Moment in Low-Level Image Processing , 2000, Comput. Vis. Image Underst..

[29]  D. Spiegelhalter,et al.  Non-invasive measurement of human endothelium dependent arterial responses: accuracy and reproducibility. , 1995, British heart journal.

[30]  R. Furchgott,et al.  The obligatory role of endothelial cells in the relaxation of arterial smooth muscle by acetylcholine , 1980, Nature.

[31]  D. Thijssen,et al.  Does arterial shear explain the magnitude of flow-mediated dilation?: a comparison between young and older humans. , 2009, American journal of physiology. Heart and circulatory physiology.

[32]  F Beux,et al.  Automatic evaluation of arterial diameter variation from vascular echographic images. , 2001, Ultrasound in medicine & biology.

[33]  J. Lekakis,et al.  Assessment of vascular wall shear stress and implications for atherosclerotic disease. , 2006, International journal of cardiology.

[34]  A. Dallai,et al.  ULA-OP: an advanced open platform for ultrasound research , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[35]  K. Kugiyama,et al.  Hyperglycemia rapidly suppresses flow-mediated endothelium-dependent vasodilation of brachial artery. , 1999, Journal of the American College of Cardiology.

[36]  K. Pyke,et al.  Peak vs. total reactive hyperemia: which determines the magnitude of flow-mediated dilation? , 2007, Journal of applied physiology.

[37]  V R Newey,et al.  Online artery diameter measurement in ultrasound images using artificial neural networks. , 2002, Ultrasound in medicine & biology.