Design and evaluation of a reflectance diffuse optical tomography system

We have designed a continuous wave, back-reflection diffuse optical tomography system; and developed a new practical calibration method including both optode efficiency and positional error corrections. System design, data acquisition and calibration protocols are described in detail. Monte Carlo (MC) simulations of photon distribution for tissue phantoms have been used to obtain the weight matrix to be used in the Rytov approximation to the photon diffusion equation. The system has been evaluated by acquiring data from a tissue phantom with a background scattering coefficient ($$\upmu _{\mathrm{s}}^{\prime }$$μs′) of $$10\,\hbox {cm}^{-1}$$10cm-1 and absorption coefficient ($$\upmu _{\mathrm{a}})$$μa) of $$0.04\,\hbox {cm}^{-1}$$0.04cm-1. An inclusion made of 1 % Intralipid and indocyanine green with $$\upmu _{s}^{\prime }=10\,\hbox {cm}^{-1}$$μs′=10cm-1 and $$\upmu _{\mathrm{a}}= 0.16\,\hbox {cm}^{-1}$$μa=0.16cm-1 was placed at a 2 cm depth from the tissue phantom surface. After calibration, the average value of the measurements over source–detector pairs at the same distance for each neighborhood was calculated. Perturbation data were obtained by subtracting the average data from the measurements with the same source–detector separation. In the reconstruction, weight matrixes obtained from MC simulation for $$\upmu _{\mathrm{s}}^{\prime }= 7$$μs′=7 to $$12\,\hbox {cm}^{-1}$$12cm-1 were used. The Depth Compensation Algorithm was used in the Tikhonov regularization to identify the location of the inclusion correctly in the reconstruction.

[1]  Y Hoshi,et al.  Visuospatial imagery is a fruitful strategy for the digit span backward task: a study with near-infrared optical tomography. , 2000, Brain research. Cognitive brain research.

[2]  A. Hielscher,et al.  Three-dimensional optical tomography of hemodynamics in the human head. , 2001, Optics express.

[3]  Quing Zhu,et al.  Depth-correction algorithm that improves optical quantification of large breast lesions imaged by diffuse optical tomography. , 2011, Journal of biomedical optics.

[4]  B. Wilson,et al.  Time resolved reflectance and transmittance for the non-invasive measurement of tissue optical properties. , 1989, Applied optics.

[5]  D. Boas,et al.  Diffuse optical reflection tomography using continuous wave illumination. , 1998, Optics express.

[6]  Tianzi Jiang,et al.  Improving performance of reflectance diffuse optical imaging using a multicentered mode. , 2006, Journal of biomedical optics.

[7]  J. Marota,et al.  Design and evaluation of a continuous-wave diffuse optical tomography system. , 1999, Optics express.

[8]  David A Boas,et al.  Simulation study of magnetic resonance imaging-guided cortically constrained diffuse optical tomography of human brain function. , 2005, Applied optics.

[9]  D. Boas,et al.  Improving the diffuse optical imaging spatial resolution of the cerebral hemodynamic response to brain activation in humans. , 2004, Optics letters.

[10]  Quing Zhu,et al.  Dual-mesh optical tomography reconstruction method with a depth correction that uses a priori ultrasound information. , 2004, Applied optics.

[11]  Fenghua Tian,et al.  Algorithmic depth compensation improves quantification and noise suppression in functional diffuse optical tomography , 2010, Biomedical optics express.

[12]  D. Boas,et al.  Diffuse optical tomography system to image brain activation with improved spatial resolution and validation with functional magnetic resonance imaging. , 2006, Applied optics.

[13]  Hanli Liu,et al.  Comprehensive investigation of three-dimensional diffuse optical tomography with depth compensation algorithm. , 2010, Journal of biomedical optics.

[14]  A. Yodh,et al.  Diffuse optics for tissue monitoring and tomography , 2010, Reports on progress in physics. Physical Society.

[15]  Anders M. Dale,et al.  Diffuse optical imaging of brain activation: approaches to optimizing image sensitivity, resolution, and accuracy , 2004, NeuroImage.

[16]  D Boas,et al.  Simultaneous imaging and optode calibration with diffuse optical tomography. , 2001, Optics express.

[17]  Hanli Liu,et al.  Development of a compensation algorithm for accurate depth localization in diffuse optical tomography. , 2010, Optics letters.

[18]  D. Boas,et al.  Volumetric diffuse optical tomography of brain activity. , 2003, Optics letters.

[19]  S. Arridge Optical tomography in medical imaging , 1999 .

[20]  Brian W. Pogue,et al.  Automatic and robust calibration of optical detector arrays for biomedical diffuse optical spectroscopy , 2012, Biomedical optics express.

[21]  L Wang,et al.  MCML--Monte Carlo modeling of light transport in multi-layered tissues. , 1995, Computer methods and programs in biomedicine.

[22]  S Zhong,et al.  Instrumentation and calibration protocol for imaging dynamic features in dense-scattering media by optical tomography. , 2000, Applied optics.