Partial discharge detection in cables using VHF capacitive couplers

In order to detect and locate partial discharge (PD) activity within HV cables and in particular cable joints, the feasibility of using a very high frequency WHO capacitive coupler technique has been investigated. In addition, an alternative PD offline test method for cable joints or cable sections within long cable systems has been developed. By energising the joint or a short section of the cable screen only this method has the advantage of reducing the power supply requirement of the test source. The application of capacitive couplers for this PD offline test method has been investigated. In order to use this approach there must be an insulation gap between the coupler and the outer sheath of the test cable. The effect of this gap on measured sensitivity has been investigated experimentally and through the use of a simulation model. Obtained results are in good agreement. Cross-correlation techniques have been implemented to automatically estimate the signal time of flight from different-coupler outputs. Methods of calibrating the coupler applied to the alternative PD offline test method have also been investigated.

[1]  N. Ahmed,et al.  On-line partial discharge detection in cables , 1998 .

[2]  A. E. Davies,et al.  Acoustic emission techniques for partial discharge detection within cable insulation , 2000 .

[3]  Steven A. Boggs,et al.  Partial discharge. XXII. High frequency attenuation in shielded solid dielectric power cable and implications thereof for PD location , 1996 .

[4]  David Pommerenke,et al.  Discrimination between internal PD and other pulses using directional coupling sensors on HV cable systems , 1999 .

[5]  Mats Leijon,et al.  Recent results in HV measurement techniques , 1995 .

[6]  F. Kreuger,et al.  Discharge detection in high voltage equipment , 1964 .

[7]  G. Stone,et al.  Fundamental Limitations in the Measurement of Corona and Partial Discharge , 1982, IEEE Transactions on Electrical Insulation.

[8]  Lars E. Lundgaard,et al.  Acoustic method for quality control and in-service periodic monitoring of medium voltage cable terminations , 1998, Conference Record of the 1998 IEEE International Symposium on Electrical Insulation (Cat. No.98CH36239).

[9]  H. Takehana,et al.  New partial discharge detection method for live UHV/EHV cable joints , 1992 .

[10]  B. F. Hampton,et al.  The excitation of UHF signals by partial discharges in GIS , 1996 .

[11]  H. Hahn,et al.  On-site partial discharge measurements on premoulded cross-bonding joints of 170 kV XLPE and EPR cables , 1998 .

[12]  D. W. Gross,et al.  Experience with an on-line monitoring system for 400 kV XLPE cables , 1996, Proceedings of 1996 Transmission and Distribution Conference and Exposition.

[13]  P. Craatz,et al.  Sensitive on-site PD measurement and location using directional coupler sensors in 110 kV prefabricated joints , 1999 .

[14]  T. Strehl,et al.  New developments in the field of PD detection and location in power cables under on-site condition , 1999 .

[15]  R. J. Jackson,et al.  Partial discharges in power-cable joints: their propagation along a crossbonded circuit and methods for their detection , 1980 .