A review of different strategies for HVAC energy saving

Abstract Decreasing the energy consumption of heating, ventilation and air conditioning (HVAC) systems is becoming increasingly important due to rising cost of fossil fuels and environmental concerns. Therefore, finding novel ways to reduce energy consumption in buildings without compromising comfort and indoor air quality is an ongoing research challenge. One proven way of achieving energy efficiency in HVAC systems is to design systems that use novel configurations of existing system components. Each HVAC discipline has specific design requirements and each presents opportunities for energy savings. Energy efficient HVAC systems can be created by re-configuring traditional systems to make more strategic use of existing system parts. Recent research has demonstrated that a combination of existing air conditioning technologies can offer effective solutions for energy conservation and thermal comfort. This paper investigates and reviews the different technologies and approaches, and demonstrates their ability to improve the performance of HVAC systems in order to reduce energy consumption. For each strategy, a brief description is first presented and then by reviewing the previous studies, the influence of that method on the HVAC energy saving is investigated. Finally, a comparison study between these approaches is carried out.

[1]  Mustafa Inalli,et al.  Experimental thermal performance evaluation of a horizontal ground-source heat pump system , 2004 .

[2]  Jafar Madadnia,et al.  Cooling Coil Design Improvement for HVAC Energy Savings and Comfort Enhancement , 2013 .

[3]  Shahram Delfani,et al.  Energy saving potential of an indirect evaporative cooler as a pre-cooling unit for mechanical cooling systems in Iran , 2010 .

[4]  Lei Wang,et al.  Solar air conditioning in Europe--an overview , 2007 .

[5]  Kadir Bakirci,et al.  Effect of a superheating and sub-cooling heat exchanger to the performance of a ground source heat pump system , 2012 .

[6]  Shahram Delfani,et al.  Investigation of a hybrid system of nocturnal radiative cooling and direct evaporative cooling , 2010 .

[7]  Tatsuo Oka,et al.  Performance of radiant cooling system integrated with ice storage , 1999 .

[8]  Saifur Rahman,et al.  Impacts of ice storage on electrical energy consumptions in office buildings , 2012 .

[9]  Jin-Yong Lee,et al.  Current status of ground source heat pumps in Korea , 2009 .

[10]  D. Torvi,et al.  Testing and modelling of a novel ceiling panel for maintaining space relative humidity by moisture transfer , 2010 .

[11]  Ivan Korolija,et al.  Influence of building parameters and HVAC systems coupling on building energy performance , 2011 .

[12]  Xinhua Xu,et al.  A supervisory control strategy for building cooling water systems for practical and real time applications , 2008 .

[13]  J. Guilpart,et al.  Numerical model of sprayed air cooled condenser coupled to refrigerating system , 2007 .

[14]  Mohammad Rasouli,et al.  Applicability and optimum control strategy of energy recovery ventilators in different climatic conditions , 2010 .

[15]  Yat Huang Yau,et al.  A review on cool thermal storage technologies and operating strategies , 2012 .

[16]  K. F. Fong,et al.  Comparative study of different solar cooling systems for buildings in subtropical city , 2010 .

[17]  Andrea Gasparella,et al.  Combination of ground source heat pumps with chemical dehumidification of air , 2005 .

[18]  Sanjeev Jain,et al.  Energy savings in a building using regenerative evaporative cooling , 2011 .

[19]  Li-Zhi Zhang,et al.  Progress on heat and moisture recovery with membranes: From fundamentals to engineering applications ☆ , 2012 .

[20]  Edward Henry Mathews,et al.  A versatile energy management system for large integrated cooling systems , 2013 .

[21]  H. G. Shen,et al.  Modeling solar-driven ejector refrigeration system offering air conditioning for office buildings , 2009 .

[22]  Daehie Hong,et al.  Performance evaluation and modeling of a hybrid cooling system combining a screw water chiller with a ground source heat pump in a building , 2010 .

[23]  J. Long,et al.  Numerical and experimental study on heat pump water heater with PCM for thermal storage , 2008 .

[24]  Ghassem Heidarinejad,et al.  A novel integrated system of ground heat exchanger and indirect evaporative cooler , 2012 .

[25]  U. Stritih,et al.  Experimental investigation of energy saving in buildings with PCM cold storage , 2010 .

[26]  Yong Chan Kim,et al.  Performance optimization of a hybrid ground source heat pump with the parallel configuration of a ground heat exchanger and a supplemental heat rejecter in the cooling mode , 2012 .

[27]  Miroslaw J. Skibniewski,et al.  Modeling and experimental validation of a solar-assisted direct expansion air conditioning system , 2013 .

[28]  Jianlei Niu,et al.  Raising evaporative cooling potentials using combined cooled ceiling and mPCM slurry storage , 2008 .

[29]  Jean Yee Hwa Yang,et al.  Experience on the application of a ground source heat pump system in an archives building , 2011 .

[30]  Lu Aye,et al.  An ice thermal storage computer model , 2001 .

[31]  Guoqiang Zhang,et al.  A combined system of chilled ceiling, displacement ventilation and desiccant dehumidification , 2007 .

[32]  Takuji Nakamura,et al.  Study of a floor supply air conditioning system using granular phase change material to augment building mass thermal storage—Heat response in small scale experiments , 2006 .

[33]  Xiaoqiang Zhai,et al.  Performance analysis on a hybrid air-conditioning system of a green building , 2006 .

[34]  James R. Sand,et al.  Active desiccant integration with packaged rooftop HVAC equipment , 2005 .

[35]  Bijan Samali,et al.  Energy-efficient HVAC systems: Simulationتempirical modelling and gradient optimization , 2013 .

[36]  Kamaruzzaman Sopian,et al.  Review of thermal energy storage for air conditioning systems , 2012 .

[37]  Amanda Pertzborn,et al.  Effective design and operation of hybrid ground-source heat pumps: Three case studies , 2011 .

[38]  Wei Yang,et al.  Current status of ground-source heat pumps in China , 2010 .

[39]  C. K. Lee,et al.  Computer simulation of ground-coupled liquid desiccant air conditioner for sub-tropical regions , 2009 .

[40]  Xinqiao Jin,et al.  Energy evaluation of optimal control strategies for central VWV chiller systems , 2007 .

[41]  Myoung-Souk Yeo,et al.  An experimental study on the environmental performance of the automated blind in summer , 2009 .

[42]  Richard S. Horng,et al.  Application of an energy management system in combination with FMCS to high energy consuming IT industries of Taiwan , 2011 .

[43]  Hongxing Yang,et al.  Investigation on air-conditioning load profile and energy consumption of desiccant cooling system for commercial buildings in Hong Kong , 2012 .

[44]  Neil Hewitt,et al.  The development of a finned phase change material (PCM) storage system to take advantage of off-peak electricity tariff for improvement in cost of heat pump operation , 2010 .

[45]  Hisham Ettouney,et al.  Performance analysis of two-stage evaporative coolers , 2004 .

[46]  Saffa Riffat,et al.  Recent developments in ejector refrigeration technologies , 2013 .

[47]  Jeffrey D. Spitler,et al.  Editorial: Ground-Source Heat Pump System Research—Past, Present, and Future , 2005 .

[48]  Reinhard Radermacher,et al.  An experimental evaluation of a residential-sized evaporatively cooled condenser , 2001 .

[49]  B. Samali,et al.  New integrated hybrid evaporative cooling system for HVAC energy efficiency improvement , 2011, 2011 IEEE/SICE International Symposium on System Integration (SII).

[50]  Andrew A. O. Tay,et al.  Numerical investigation of transfer coefficients of an evaporatively-cooled condenser , 2011 .

[51]  Shailesh Kumar,et al.  An experimental study of a novel dew point evaporative cooling system , 2010 .

[52]  Ìbrahim B Kilkis Utilization of wind energy in space heating and cooling with hybrid HVAC systems and heat pumps , 1999 .

[53]  Jing Chen,et al.  Global optimization of a central air-conditioning system using decomposition-coordination method , 2010 .

[54]  Mohammad Shakir Nasif,et al.  Membrane heat exchanger in HVAC energy recovery systems, systems energy analysis , 2010 .

[55]  Jianlei Niu,et al.  Energy requirements for conditioning fresh air and the long-term savings with a membrane-based energy recovery ventilator in Hong Kong , 2001 .

[56]  Abdeen Mustafa Omer,et al.  Ground-source heat pumps systems and applications , 2008 .

[57]  Jianlei Niu,et al.  Energy savings potential of chilled-ceiling combined with desiccant cooling in hot and humid climates , 2002 .

[58]  P. A. Rubini,et al.  Analysis of ice cool thermal storage for a clinic building in Kuwait , 2006 .

[59]  E. Hajidavalloo,et al.  Performance improvement of air-cooled refrigeration system by using evaporatively cooled air condenser. , 2010 .

[60]  Michalis Gr. Vrachopoulos,et al.  Incorporated evaporative condenser , 2007 .

[61]  Vahid Vakiloroaya,et al.  Design Optimization of the Cooling Coil for HVAC Energy Saving and Comfort Enhancement , 2013 .

[62]  Arif Hepbasli,et al.  Experimental study of a closed loop vertical ground source heat pump system , 2003 .

[63]  Javier F. Urchueguía,et al.  Optimization of hybrid – ground coupled and air source – heat pump systems in combination with thermal storage , 2010 .

[64]  Marco D’Orazio,et al.  Energy performance evaluation of a novel evaporative cooling technique , 2010 .

[65]  Paisarn Naphon On the performance of air conditioner with heat pipe for cooling air in the condenser , 2010 .

[66]  Shahram Delfani,et al.  Experimental investigation of heat recovery system for building air conditioning in hot and humid areas , 2012 .

[67]  Carey J. Simonson,et al.  Performance testing of a counter-cross-flow run-around membrane energy exchanger (RAMEE) system for HVAC applications , 2010 .

[68]  Francisco Javier Rey Martínez,et al.  Design and experimental study of a mixed energy recovery system, heat pipes and indirect evaporative equipment for air conditioning , 2003 .

[69]  Jeffrey D. Spitler,et al.  Review of development from GSHP to UTES in China and other countries , 2009 .

[70]  Hatef Madani,et al.  Run-around coil ventilation heat recovery system: A comparative study between different system configurations , 2012 .

[71]  Yi Jiang,et al.  Theoretical and testing performance of an innovative indirect evaporative chiller , 2010 .

[72]  F. W. Yu,et al.  Improved energy performance of air-cooled chiller system with mist pre-cooling , 2011 .

[73]  F. W. Yu,et al.  Improved energy performance of air cooled centrifugal chillers with variable chilled water flow , 2008 .

[74]  Peter B. Luh,et al.  An integrated control of shading blinds, natural ventilation, and HVAC systems for energy saving and human comfort , 2010, 2010 IEEE International Conference on Automation Science and Engineering.

[75]  Danijela Nikolić,et al.  A simulation appraisal of performance of different HVAC systems in an office building , 2011 .

[76]  Xiao Feng,et al.  Cumulative exergy analysis of ice thermal storage air conditioning system , 2012 .

[77]  Edward Henry Mathews,et al.  Needs and trends in building and HVAC system design tools , 2002 .

[78]  José Fernández-Seara,et al.  Experimental analysis of an air-to-air heat recovery unit for balanced ventilation systems in residential buildings , 2011 .

[79]  Wu Chen,et al.  Research on a novel DDC-based capacity controller for the direct-expansion variable-air-volume A/C system , 2010 .

[80]  Jianing Zhao,et al.  Experimental Study on Indoor Air Temperature Distribution of Gravity Air-Conditioning for Cooling , 2012 .

[81]  A. Athienitis,et al.  The impact of shading design and control on building cooling and lighting demand , 2007 .

[82]  M. Zaheer-uddin,et al.  Dynamic simulation of energy management control functions for HVAC systems in buildings , 2006 .

[83]  Claude-Alain Roulet,et al.  Real heat recovery with air handling units , 2001 .

[84]  Jae-Keun Lee,et al.  Cooling performance of a vertical ground-coupled heat pump system installed in a school building , 2009 .

[85]  W. F. Stoecker,et al.  Refrigeration and air conditioning , 1958 .

[86]  Yan-ming Kang,et al.  Applicability of air-to-air heat recovery ventilators in China , 2009 .

[87]  Omar M. Al-Rabghi,et al.  A survey of energy efficient strategies for effective air conditioning , 2004 .

[88]  Shih-Cheng Hu,et al.  A comparative study on energy consumption for HVAC systems of high-tech FABs , 2007 .

[89]  Sergio Colle,et al.  A general model for evaluation of vapor ejectors performance for application in refrigeration , 2012 .

[90]  H. Manz,et al.  Experimental and numerical study of a duct/heat exchanger unit for building ventilation , 2000 .

[91]  N. Enteria,et al.  The role of the thermally activated desiccant cooling technologies in the issue of energy and environment , 2011 .

[92]  Teresa Magraner,et al.  Comparison between design and actual energy performance of a HVAC-ground coupled heat pump system in cooling and heating operation , 2010 .

[93]  Luis Pérez-Lombard,et al.  A review on buildings energy consumption information , 2008 .

[94]  H. J. Hussain,et al.  Ecomomic Assessment of Chilled Water Thermal Storage and Conventional Air-Conditioning Systems , 2012 .

[95]  Ahmed Hamza H. Ali,et al.  Passive cooling of water at night in uninsulated open tank in hot arid areas , 2007 .

[96]  Predrag Stojan Hrnjak,et al.  Ejector Refrigeration: An Overview of Historical and Present Developments with an Emphasis on Air-Conditioning Applications , 2008 .

[97]  S. M. Hasnain,et al.  Need for thermal-storage air-conditioning in Saudi Arabia , 2000 .

[98]  Anastassios M. Stamatelos,et al.  Effect of climatic conditions on the design optimization of heat pump systems for space heating and cooling , 1998 .

[99]  Umberto Desideri,et al.  Solar-powered cooling systems: Technical and economic analysis on industrial refrigeration and air-conditioning applications , 2009 .

[100]  Bo-Ren Chen,et al.  Application of thermal battery in the ice storage air-conditioning system as a subcooler , 2007 .

[101]  M. Fasiuddin,et al.  HVAC system strategies for energy conservation in commercial buildings in Saudi Arabia , 2011 .

[102]  Pei-Xue Jiang,et al.  Hybrid vapor compression refrigeration system with an integrated ejector cooling cycle , 2012 .

[103]  Javier F. Urchueguía,et al.  Efficiency improvement of a ground coupled heat pump system from energy management , 2011 .

[104]  Mohammad. Rasul,et al.  Feasibility of thermal energy storage systems in an institutional building in subtropical climates in Australia , 2011 .

[105]  Bijan Samali,et al.  Modelling and performance prediction of an integrated central cooling plant for HVAC energy efficiency improvement , 2013 .

[106]  Ibrahim Dincer,et al.  Energy and exergy analyses of an ice-on-coil thermal energy storage system , 2011 .