Analysis of frequency distribution of ground fault-current magnitude in transmission networks for electrical safety evaluation

Abstract Ground Potential Rise (GPR) evaluation under fault conditions is important for the evaluation of electrical safety risk to human beings who are present in and around electric installations. Current national and international standards recommend such evaluation is based on a set of ‘worst-case’ conditions that include a simplified fault current calculation procedure based on assuming a maximum value. Accordingly, this approach may lead to over-design of grounding systems in certain cases by overestimating individual risk. To address this and move towards a comprehensive probabilistic assessment of risk, a more detailed model of the electric network is required for fault current magnitude evaluation. This paper describes the application of the multi-conductor method to determine fault current distribution on transmission networks. First, a model of a portion of the UK transmission network is built and the fault current and its distribution among the phases, ground wire and ground is evaluated for three example fault positions. It is found that the position of the fault along the line, substation bus section status and proximity to generation affect greatly the current distribution. Then, a transmission model based on the national network is built, and the effects of system loading and generation on fault current magnitude were also considered. A complete frequency distribution of fault current magnitude is obtained and the results demonstrate the value of such description for the probabilistic assessment of human safety in grounding system design.

[1]  S. S. Moorthy,et al.  A New Phase-Coordinate Transformer Model for y Bus Analysis , 2002 .

[2]  Fabio Bignucolo,et al.  Generalised transformer modelling for power flow calculation in multi-phase unbalanced networks , 2017 .

[3]  D. Mukhedkar,et al.  Ground Fault Current Distribution in Sub-Station, Tower and Ground Wire , 1979, IEEE Transactions on Power Apparatus and Systems.

[4]  J. Burke,et al.  Characteristics of Fault Currents on Distribution Systems , 1984, IEEE Transactions on Power Apparatus and Systems.

[5]  A. Haddad,et al.  Probability Surface Distributions for Application in Grounding Safety Assessment , 2012, IEEE Transactions on Power Delivery.

[6]  H. B. Gooi,et al.  Distribution of Ground Fault Currents Along Transmission Lines -- An Improved Algorithm , 1985 .

[7]  Yun Seng Lim,et al.  Analytical approach to probabilistic prediction of voltage sags on transmission networks , 2002 .

[8]  J. Nahman,et al.  Earth fault currents and potentials distribution in composite systems , 1995 .

[9]  S. Mangione,et al.  Safety Concerns on Ground Fault Application Transfer Phenomenon in HV Installations , 2007, 2007 IEEE Symposium on Product Compliance Engineering.

[10]  F. Dawalibi,et al.  Ground Fault Current Distribution Between Soil and Neutral Conductors , 1980, IEEE Transactions on Power Apparatus and Systems.

[11]  M. A. El-Kady,et al.  Probabilistic Short-Circuit Analysis by Monte Carlo Simulations , 1983, IEEE Power Engineering Review.

[12]  Tsai-Hsiang Chen,et al.  Open wye-open delta and open delta-open delta transformer models for rigorous distribution system analysis , 1992 .

[13]  M. El-kady,et al.  An Advanced Probabilistic Short-Circuit Program , 1983, IEEE Transactions on Power Apparatus and Systems.

[14]  T. Inoue,et al.  Three-phase cogenerator and transformer models for distribution system analysis , 1991 .

[15]  F. Dawalibi,et al.  Measurements and Computations of Fault Current Distribution on Overhead Transmission Lines , 1984, IEEE Transactions on Power Apparatus and Systems.

[16]  A. Haddad,et al.  Proposal for Probabilistic Risk Assessment in Grounding Systems and Its Application to Transmission Substations , 2012, IEEE Transactions on Power Delivery.

[17]  R. H. Galloway,et al.  Calculation of electrical parameters for short and long polyphase transmission lines , 1964 .

[18]  Roberto Benato,et al.  Determination of Steady-State and Faulty Regimes of Overhead Lines by Means of Multiconductor Cell Analysis (MCA) , 2012 .

[19]  J. R. Carson Wave propagation in overhead wires with ground return , 1926 .

[20]  Mohamad Nassereddine,et al.  Relation between transmission lines coupling factor and over head earth wire length: its impacts on fault current distributions , 2014 .

[21]  W. K. Daily,et al.  Cost reduction and minimization of land based on an accurate determination of fault current distribution in shield wires and grounding systems , 1993 .

[22]  Roberto Turri,et al.  A Correction Current Injection Method for Power Flow Analysis of Unbalanced Multiple-grounded 4-wire Distribution Networks , 2016 .

[23]  A. Meliopoulos,et al.  Analysis of Grounding Systems , 1981, IEEE Transactions on Power Apparatus and Systems.

[24]  R. Turri,et al.  A procedure for detailed assessment of ground fault-current distribution in transmission networks , 2016, 2016 51st International Universities Power Engineering Conference (UPEC).

[25]  E. Viel,et al.  Fault current distribution in HV cable systems , 2000 .

[26]  R. Turri,et al.  Computation of the Electromagnetic Coupling of Parallel Untransposed Power Lines , 2006, Proceedings of the 41st International Universities Power Engineering Conference.

[27]  M.G. Da Silva,et al.  A new methodology for probabilistic short-circuit evaluation with applications in power quality analysis , 2006, IEEE Transactions on Power Systems.

[28]  L. M. Popovic,et al.  Practical method for evaluating ground fault current distribution in station, towers and ground wire , 1998 .