Stresses produced by different textile mesh implants in a tissue equivalent

Abstract Two single-incision mini-slings used for treating urinary incontinence in women are compared with respect to the stresses they produce in their surrounding tissue. In an earlier paper we experimentally observed that these implants produce considerably different stress distributions in a muscle tissue equivalent. Here we perform 2D finite element analyses to compare the shear stresses and normal stresses in the tissue equivalent for the two meshes and to investigate their failure behavior. The results clearly show that the Gynecare TVT fails for increasing loads in a zipper-like manner because it gradually debonds from the surrounding tissue. Contrary to that, the tissue at the ends of the DynaMesh-SIS direct may rupture but only at higher loads. The simulation results are in good agreement with the experimental observations thus the computational model helps to interpret the experimental results and provides a tool for qualitative evaluation of mesh implants.

[1]  U. Klinge,et al.  New objective measurement to characterize the porosity of textile implants. , 2008, Journal of biomedical materials research. Part B, Applied biomaterials.

[2]  M. Bennett,et al.  Biomechanical properties of raw meshes used in pelvic floor reconstruction , 2008, International Urogynecology Journal.

[3]  L. Meyn,et al.  Tensile properties of commonly used prolapse meshes , 2009, International Urogynecology Journal.

[4]  B Calvo,et al.  Mechanical behaviour of synthetic surgical meshes: finite element simulation of the herniated abdominal wall. , 2011, Acta biomaterialia.

[5]  Y. Novitsky,et al.  Anisotropic evaluation of synthetic surgical meshes , 2011, Hernia.

[6]  E. Mazza,et al.  Uniaxial and biaxial mechanical characterization of a prosthetic mesh at different length scales. , 2014, Journal of the mechanical behavior of biomedical materials.

[7]  B. Röhrnbauer Mechanical characterization and modeling of prosthetic meshes , 2013 .

[8]  U. Klinge,et al.  Elongation of textile pelvic floor implants under load is related to complete loss of effective porosity, thereby favoring incorporation in scar plates. , 2014, Journal of biomedical materials research. Part A.

[9]  Corey R Deeken,et al.  Physicomechanical evaluation of polypropylene, polyester, and polytetrafluoroethylene meshes for inguinal hernia repair. , 2011, Journal of the American College of Surgeons.

[10]  U. Klinge,et al.  New measurements to compare soft tissue anchoring systems in pelvic floor surgery. , 2012, Journal of biomedical materials research. Part B, Applied biomaterials.