Ultrasensitive hot-electron kinetic-inductance detectors operating well below the superconducting transition

While most experimental studies of kinetic-inductance sensors have been limited so far by the temperature range near the superconducting transition, kinetic-inductance detectors can be very sensitive at temperatures well below the transition, where the number of equilibrium quasiparticles is exponentially small. In this regime, a shift of the quasiparticle chemical potential under radiation results in the change of the kinetic inductance. We modeled the noise characteristics of the kinetic-inductance detectors made from disordered superconducting Nb, NbC, and MoRe films. Low-phonon transparency of the interface between the superconductor and the substrate causes substantial retrapping of phonons providing high quantum efficiency and the operating time of ∼1 ms at ≈1 K. Due to the small number of quasiparticles, the noise equivalent power of the detector determined by the quasiparticle generation–recombination noise can be as small as ∼10−19 W/Hz at He4 temperatures.

[1]  D. Scalapino,et al.  SUPERCONDUCTING STATE UNDER THE INFLUENCE OF EXTERNAL DYNAMIC PAIR BREAKING. , 1972 .

[2]  Michael Tinkham,et al.  Introduction to Superconductivity , 1975 .

[3]  Erich N. Grossman,et al.  Far-infrared kinetic-inductance detectors , 1991 .

[4]  Nathan Bluzer,et al.  Temporal relaxation measurements of photoinduced nonequilibrium in superconductors , 1992 .

[5]  Hegmann Fa,et al.  Origin of the fast photoresponse of epitaxial YBa2Cu3O7- delta thin films. , 1993 .

[6]  M. D. Audley,et al.  A prototype kinetic inductance thermometer for X-ray calorimetry , 1993 .

[7]  M. Forrester,et al.  Superconducting quantum detectors in YBCO , 1994 .

[8]  Mark W. Johnson,et al.  Bolometric and nonbolometric infrared photoresponses in ultrathin superconducting NbN films , 1996 .

[9]  A. Sergeev,et al.  PHOTORESPONSE MECHANISMS OF THIN SUPERCONDUCTING FILMS AND SUPERCONDUCTING DETECTORS , 1996 .

[10]  B. Bumble,et al.  Fabrication of a diffusion cooled superconducting hot electron bolometer for THz mixing applications , 1997, IEEE Transactions on Applied Superconductivity.

[11]  G. Gol'tsman,et al.  Influence of phonon trapping on the performance of NbN kinetic inductance detectors , 1997, IEEE Transactions on Applied Superconductivity.

[12]  James J. Bock,et al.  Silicon nitride micromesh bolometer arrays for SPIRE , 1998, Astronomical Telescopes and Instrumentation.

[13]  E. V. Pechen,et al.  Electron-phonon scattering rate in impure NbC films , 1998 .

[14]  E. Gershenzon,et al.  Possibility of fabricating an inductive high-speed detector for electromagnetic radiation using thin YBa2Cu3O7−δ films , 1999 .

[15]  Lee D. Feinberg,et al.  Scientific motivation and technology requirements for the SPIRIT and SPECS far-infrared/submillimeter space interferometers , 2000, Astronomical Telescopes + Instrumentation.

[16]  Boris S. Karasik,et al.  Photon-noise-limited direct detector based on disorder-controlled electron heating , 2000 .

[17]  A. Sergeev,et al.  Millisecond electron–phonon relaxation in ultrathin disordered metal films at millikelvin temperatures , 2001, cond-mat/0104083.