Application of failure mode and effect analysis in a radiology department.

With increasing deployment, complexity, and sophistication of equipment and related processes within the clinical imaging environment, system failures are more likely to occur. These failures may have varying effects on the patient, ranging from no harm to devastating harm. Failure mode and effect analysis (FMEA) is a tool that permits the proactive identification of possible failures in complex processes and provides a basis for continuous improvement. This overview of the basic principles and methodology of FMEA provides an explanation of how FMEA can be applied to clinical operations in a radiology department to reduce, predict, or prevent errors. The six sequential steps in the FMEA process are explained, and clinical magnetic resonance imaging services are used as an example for which FMEA is particularly applicable. A modified version of traditional FMEA called Healthcare Failure Mode and Effect Analysis, which was introduced by the U.S. Department of Veterans Affairs National Center for Patient Safety, is briefly reviewed. In conclusion, FMEA is an effective and reliable method to proactively examine complex processes in the radiology department. FMEA can be used to highlight the high-risk subprocesses and allows these to be targeted to minimize the future occurrence of failures, thus improving patient safety and streamlining the efficiency of the radiology department.

[1]  Jacob Sosna,et al.  Managing an acute adverse event in a radiology department. , 2008, Radiographics : a review publication of the Radiological Society of North America, Inc.

[2]  D. Linkin,et al.  Applicability of Healthcare Failure Mode and Effects Analysis to healthcare epidemiology: evaluation of the sterilization and use of surgical instruments. , 2005, Clinical infectious diseases : an official publication of the Infectious Diseases Society of America.

[3]  R. Esmail,et al.  Using Healthcare Failure Mode and Effect Analysis tool to review the process of ordering and administrating potassium chloride and potassium phosphate. , 2005, Healthcare quarterly.

[4]  Joseph M. Derosier,et al.  Using health care Failure Mode and Effect Analysis: the VA National Center for Patient Safety's prospective risk analysis system. , 2002, The Joint Commission journal on quality improvement.

[5]  M. M. P. Habraken,et al.  Prospective risk analysis of health care processes: A systematic evaluation of the use of HFMEA™ in Dutch health care , 2009, Ergonomics.

[6]  Wayne Adachi,et al.  Use of failure mode and effects analysis in improving the safety of i.v. drug administration. , 2005, American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists.

[7]  J. Burgmeier,et al.  Failure mode and effect analysis: an application in reducing risk in blood transfusion. , 2002, The Joint Commission journal on quality improvement.

[8]  P. Bonnabry,et al.  Use of a systematic risk analysis method to improve safety in the production of paediatric parenteral nutrition solutions , 2005, Quality and Safety in Health Care.

[9]  D. Reith,et al.  Identification of Priorities for Medication Safety in Neonatal Intensive Care , 2005, Drug safety.

[10]  Pascale Carayon,et al.  Using failure mode and effects analysis to plan implementation of smart i.v. pump technology. , 2006, American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists.

[11]  Jolene Fox,et al.  Utilization of Failure Mode Effects Analysis in Trauma Patient Registration , 2007, Quality management in health care.

[12]  Rathachai Kaewlai,et al.  Radiology failure mode and effect analysis: what is it? , 2009, Radiology.

[13]  M. Apkon,et al.  Design of a safer approach to intravenous drug infusions: failure mode effects analysis , 2004, Quality and Safety in Health Care.

[14]  C. M. Tilburg,et al.  Health care failure mode and effect analysis: a useful proactive risk analysis in a pediatric oncology ward , 2006, Quality and Safety in Health Care.

[15]  B. Franklin,et al.  Is Failure Mode and Effect Analysis Reliable? , 2009, Journal of patient safety.

[16]  Peter Davey,et al.  Quality of care in sepsis management: development and testing of measures for improvement. , 2007, The Journal of antimicrobial chemotherapy.

[17]  Maria Laura Chiozza,et al.  FMEA: a model for reducing medical errors. , 2009, Clinica chimica acta; international journal of clinical chemistry.

[18]  J. Kozakiewicz,et al.  Safe chemotherapy administration: using failure mode and effects analysis in computerized prescriber order entry. , 2005, American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists.

[19]  Using HFMEA to assess potential for patient harm from tubing misconnections. , 2006, Joint Commission journal on quality and patient safety.

[20]  E Williams,et al.  The use of failure mode effect and criticality analysis in a medication error subcommittee. , 1994, Hospital pharmacy.