P-33: A Measurement and Analysis Method of Image Sticking in LCD
暂无分享,去创建一个
In this paper, the evaluation method of image sticking was proposed by measuring 2-Dimension of luminance level. We used the 2D-CCD luminance meter and pattern generator for chessboard pattern. The test samples were burned in about 2 hours and the tested data were normalized by data before image sticking test. The normalized value was so sensitive for determining the image sticking level. We proposed a new parameter of ISV(image sticking value) for increasing sensitivity. It was resulted that the image sticking under ISV 1% was difficult to be detected by human eye. And the image sticking over ISV 2% was strongly detected. It was found that this test method is similar to human eye testing result. Therefore, this analysis method helps to determine the objective image sticking level.
[1] Po-Lun Chen,et al. An effective method for evaluating the image-sticking effect of TFT-LCDs by interpretative modelling of optical measurements , 2000 .
[2] Thierry R. Leroux. New uniformity measurement method for LCD panels , 1999, Electronic Imaging.
[3] C. Benjamin Wooley,et al. Digital imaging colorimeter for fast measurement of chromaticity coordinate and luminance uniformity of displays , 2001, IS&T/SPIE Electronic Imaging.