Capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry for quantitative parallel reaction monitoring of peptide abundance and single-shot proteomic analysis of a human cell line.

We coupled capillary zone electrophoresis (CZE) with an ultrasensitive electrokinetically pumped nanospray ionization source for tandem mass spectrometry (MS/MS) analysis of complex proteomes. We first used the system for the parallel reaction monitoring (PRM) analysis of angiotensin II spiked in 0.45mg/mL of bovine serum albumin (BSA) digest. A calibration curve was generated between the loading amount of angiotensin II and intensity of angiotensin II fragment ions. CZE-PRM generated a linear calibration curve across over 4.5 orders of magnitude dynamic range corresponding to angiotensin II loading amount from 2amole to 150fmole. The relative standard deviations (RSDs) of migration time were <4% and the RSDs of fragment ion intensity were ∼20% or less except 150fmole angiotensin II loading amount data (∼36% RSD). We further applied the system for the first bottom up proteomic analysis of a human cell line using CZE-MS/MS. We generated 283 protein identifications from a 1h long, single-shot CZE MS/MS analysis of the MCF7 breast cancer cell line digest, corresponding to ∼80ng loading amount. The MCF7 digest was fractionated using a C18 solid phase extraction column; single-shot analysis of a single fraction resulted in 468 protein identifications, which is by far the largest number of protein identifications reported for a mammalian proteomic sample using CZE.

[1]  G. D. de Jong,et al.  Capillary electrophoresis-mass spectrometry for the analysis of intact proteins. , 2007, Journal of chromatography. A.

[2]  G. D. de Jong,et al.  Performance of a sheathless porous tip sprayer for capillary electrophoresis-electrospray ionization-mass spectrometry of intact proteins. , 2010, Journal of chromatography. A.

[3]  Liangliang Sun,et al.  Ultrasensitive and fast bottom-up analysis of femtogram amounts of complex proteome digests. , 2013, Angewandte Chemie.

[4]  Richard B. Keithley,et al.  Capillary isoelectric focusing-tandem mass spectrometry and reversed-phase liquid chromatography-tandem mass spectrometry for quantitative proteomic analysis of differentiating PC12 cells by eight-plex isobaric tags for relative and absolute quantification. , 2013, Analytical chemistry.

[5]  G. D. de Jong,et al.  Capillary electrophoresis–mass spectrometry for the analysis of intact proteins 2007–2010 , 2011, Electrophoresis.

[6]  N. Dovichi,et al.  Accurate determination of peptide phosphorylation stoichiometry via automated diagonal capillary electrophoresis coupled with mass spectrometry: proof of principle. , 2013, Analytical chemistry.

[7]  Rawi Ramautar,et al.  High capacity capillary electrophoresis-electrospray ionization mass spectrometry: coupling a porous sheathless interface with transient-isotachophoresis. , 2010, Analytical chemistry.

[8]  R. Aebersold,et al.  Selected reaction monitoring–based proteomics: workflows, potential, pitfalls and future directions , 2012, Nature Methods.

[9]  Werner Zolg,et al.  Quantification of C‐reactive protein in the serum of patients with rheumatoid arthritis using multiple reaction monitoring mass spectrometry and 13C‐labeled peptide standards , 2004, Proteomics.

[10]  J. Yates,et al.  Improving the comprehensiveness and sensitivity of sheathless capillary electrophoresis-tandem mass spectrometry for proteomic analysis. , 2012, Analytical chemistry.

[11]  N. Dovichi,et al.  Capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry as an alternative proteomics platform to ultraperformance liquid chromatography-electrospray ionization-tandem mass spectrometry for samples of intermediate complexity. , 2012, Analytical chemistry.

[12]  M. MacCoss,et al.  Capillary electrophoresis with Orbitrap-Velos mass spectrometry detection. , 2012, Talanta.

[13]  Alexey I Nesvizhskii,et al.  Empirical statistical model to estimate the accuracy of peptide identifications made by MS/MS and database search. , 2002, Analytical chemistry.

[14]  R. Ramautar,et al.  CE-MS for proteomics: Advances in interface development and application. , 2012, Journal of proteomics.

[15]  Rawi Ramautar,et al.  CE‐MS for metabolomics: Developments and applications in the period 2010–2012 , 2013, Electrophoresis.

[16]  B. Sarg,et al.  Comparing and Combining Capillary Electrophoresis Electrospray Ionization Mass Spectrometry and Nano–Liquid Chromatography Electrospray Ionization Mass Spectrometry for the Characterization of Post-translationally Modified Histones , 2013, Molecular & Cellular Proteomics.

[17]  Stable, reproducible, and automated capillary zone electrophoresis-tandem mass spectrometry system with an electrokinetically pumped sheath-flow nanospray interface. , 2014, Analytica chimica acta.

[18]  M. Moini Simplifying CE-MS operation. 2. Interfacing low-flow separation techniques to mass spectrometry using a porous tip. , 2007, Analytical chemistry.

[19]  N. Dovichi,et al.  Fast top-down intact protein characterization with capillary zone electrophoresis-electrospray ionization tandem mass spectrometry. , 2013, Analytical chemistry.

[20]  B. Sarg,et al.  Optimization and evaluation of a sheathless capillary electrophoresis-electrospray ionization mass spectrometry platform for peptide analysis: comparison to liquid chromatography-electrospray ionization mass spectrometry. , 2011, Analytical chemistry.

[21]  Leigh Anderson,et al.  Quantitative Mass Spectrometric Multiple Reaction Monitoring Assays for Major Plasma Proteins* , 2006, Molecular & Cellular Proteomics.

[22]  Steven P Gygi,et al.  Target-decoy search strategy for increased confidence in large-scale protein identifications by mass spectrometry , 2007, Nature Methods.

[23]  T. Hankemeier,et al.  Capillary electrophoresis‐mass spectrometry using a flow‐through microvial interface for cationic metabolome analysis , 2014, Electrophoresis.

[24]  J. Yates,et al.  Identification of proteins in complexes by solid-phase microextraction/multistep elution/capillary electrophoresis/tandem mass spectrometry. , 1999, Analytical chemistry.

[25]  E. Maxwell,et al.  Twenty years of interface development for capillary electrophoresis-electrospray ionization-mass spectrometry. , 2008, Analytica chimica acta.

[26]  T. Hankemeier,et al.  Simple capillary electrophoresis-mass spectrometry method for complex glycan analysis using a flow-through microvial interface. , 2014, Analytical chemistry.

[27]  N. Dovichi,et al.  Simplified capillary electrophoresis nanospray sheath-flow interface for high efficiency and sensitive peptide analysis. , 2010, Rapid communications in mass spectrometry : RCM.

[28]  Liangliang Sun,et al.  Capillary zone electrophoresis for analysis of complex proteomes using an electrokinetically pumped sheath flow nanospray interface , 2014, Proteomics.

[29]  Richard D. Smith,et al.  Capillary isotachophoresis-nanoelectrospray ionization-selected reaction monitoring MS via a novel sheathless interface for high sensitivity sample quantification. , 2013, Analytical chemistry.

[30]  Richard D. Smith,et al.  Improving the Sensitivity of Mass Spectrometry by Using a New Sheath Flow Electrospray Emitter Array at Subambient Pressures , 2014, Journal of The American Society for Mass Spectrometry.

[31]  N. Dovichi,et al.  Quantitative multiple reaction monitoring of peptide abundance introduced via a capillary zone electrophoresis-electrospray interface. , 2012, Analytical chemistry.

[32]  R. Aebersold,et al.  Selected reaction monitoring for quantitative proteomics: a tutorial , 2008, Molecular systems biology.

[33]  N. Dovichi,et al.  Uncovering immobilized trypsin digestion features from large-scale proteome data generated by high-resolution mass spectrometry. , 2014, Journal of chromatography. A.

[34]  Liangliang Sun,et al.  Single-shot proteomics using capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry with production of more than 1250 Escherichia coli peptide identifications in a 50 min separation. , 2013, Analytical chemistry.

[35]  N. Dovichi,et al.  Capillary zone electrophoresis-multiple reaction monitoring from 100 pg of RAW 264.7 cell lysate digest. , 2013, The Analyst.

[36]  M. Girolami,et al.  Naturally Occurring Human Urinary Peptides for Use in Diagnosis of Chronic Kidney Disease* , 2010, Molecular & Cellular Proteomics.

[37]  Ioan Marginean,et al.  Picoelectrospray Ionization Mass Spectrometry Using Narrow-Bore Chemically Etched Emitters , 2013, Journal of The American Society for Mass Spectrometry.

[38]  N. Dovichi,et al.  CZE‐ESI‐MS/MS system for analysis of subnanogram amounts of tryptic digests of a cellular homogenate , 2012, Proteomics.

[39]  N. Dovichi,et al.  Integrated capillary zone electrophoresis-electrospray ionization tandem mass spectrometry system with an immobilized trypsin microreactor for online digestion and analysis of picogram amounts of RAW 264.7 cell lysate. , 2013, Analytical chemistry.

[40]  N. Dovichi,et al.  High sensitivity capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry for the rapid analysis of complex proteomes. , 2013, Current opinion in chemical biology.

[41]  G. D. de Jong,et al.  Low-flow sheathless capillary electrophoresis-mass spectrometry for sensitive glycoform profiling of intact pharmaceutical proteins. , 2013, Analytical chemistry.

[42]  E. Maxwell,et al.  Flow-through microvial facilitating interface of capillary isoelectric focusing and electrospray ionization mass spectrometry. , 2011, Analytical chemistry.

[43]  Emily H Turner,et al.  Bioanalytical applications of capillary electrophoresis. , 2006, Analytical chemistry.

[44]  V. Sanz-Nebot,et al.  Low-picomolar analysis of peptides by on-line coupling of fritless solid-phase extraction to sheathless capillary electrophoresis-mass spectrometry. , 2014, Journal of chromatography. A.

[45]  N. Dovichi,et al.  Bottom‐up proteome analysis of E. coli using capillary zone electrophoresis‐tandem mass spectrometry with an electrokinetic sheath‐flow electrospray interface , 2013, Proteomics.

[46]  Derek J. Bailey,et al.  Parallel Reaction Monitoring for High Resolution and High Mass Accuracy Quantitative, Targeted Proteomics* , 2012, Molecular & Cellular Proteomics.