Model vs . Data based Approaches Applied to Fault Diagnosis in Drinking Water Transport Networks

In this paper, the problem of fault diagnosis in drinking water transport networks (DWTNs) is addressed. Two different fault diagnosis approaches are proposed to deal with this problem. The first one is based on a model-based approach exploiting a-priori information regarding physical/temporal relations existing between the measured variables in the monitored system, providing fault detection and isolation capabilities by means of the residuals generated using these measured variables and their estimations. This a-priori information is provided by the topology and the physical relations between the elements constituting the system, which is used by design in order to derive fault diagnosis. Differently, the second approach does not require the physical a-priori information of the network to operate. It relies on a data-driven solution meant to exploit the spatial and temporal relationships present in the acquired data streams to detect and isolate faults. Relationships between data streams are modelled through sequences of linear dynamic time-invariant models whose estimated coefficients are used to feed a Hidden Markov Model (HMM). When the pattern of estimated coefficients cannot be explained by the trained HMM, a change is detected. Afterwards, a cognitive method based on a functional graph representation of the system isolates the fault. Finally, a performance comparison between these two approaches is carried out using a part of the Barcelona water transport network. ∗Corresponding author Email address: miquel.angel.cuguero@upc.edu (M.À. Cugueró-Escofet)

[1]  Zoran Kapelan,et al.  Evolutionary Algorithm and Expectation Maximization Strategies for Improved Detection of Pipe Bursts and Other Events in Water Distribution Systems , 2014 .

[2]  Zoran Kapelan,et al.  Automated Detection of Pipe Bursts and Other Events in Water Distribution Systems , 2014 .

[3]  Huanhuan Chen,et al.  Combining learning in model space fault diagnosis with data validation/reconstruction: Application to the Barcelona water network , 2014, Eng. Appl. Artif. Intell..

[4]  Zoran Kapelan,et al.  Geostatistical techniques for approximate location of pipe burst events in water distribution systems , 2013 .

[5]  Vicenç Puig,et al.  Limnimeter and rain gauge FDI in sewer networks using an interval parity equations based detection approach and an enhanced isolation scheme , 2013 .

[6]  Richard Mounce,et al.  Novelty detection for time series data analysis in water distribution systems using support vector machines , 2011 .

[7]  Vicenç Puig,et al.  Methodology for leakage isolation using pressure sensitivity analysis in water distribution networks , 2011 .

[8]  Joby Boxall,et al.  Implementation of an on-line artificial intelligence district meter area flow meter data analysis system for abnormality detection: a case study , 2010 .

[9]  Vicenç Puig,et al.  Validation and reconstruction of flow meter data in the Barcelona water distribution network , 2010 .

[10]  Vicenç Puig,et al.  Fault Diagnosis Using a Timed Discrete-Event Approach Based on Interval Observers: Application to Sewer Networks , 2010, IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans.

[11]  Joby Boxall,et al.  Development and Verification of an Online Artificial Intelligence System for Detection of Bursts and Other Abnormal Flows , 2010 .

[12]  Didier Maquin,et al.  Fault measurement detection in an urban water supply network , 2006 .

[13]  G Olsson,et al.  Failure monitoring in water distribution networks. , 2006, Water science and technology : a journal of the International Association on Water Pollution Research.

[14]  Avi Ostfeld,et al.  Optimal Layout of Early Warning Detection Stations for Water Distribution Systems Security , 2004 .

[15]  Peter R. Winters,et al.  Forecasting Sales by Exponentially Weighted Moving Averages , 1960 .

[16]  F. J. Arregui,et al.  Burst Detection in Water Networks Using Principal Component Analysis , 2012 .

[17]  Zheng Yi Wu,et al.  Pressure-dependent leak detection model and its application to a district water system , 2010 .

[18]  Vicenç Puig,et al.  Leakage isolation using pressure sensitivity analysis in water distribution networks: Application to the Barcelona case study , 2010 .