An Applicable Method to Improve Transient and Dynamic Performance of Power System Equipped With DFIG-Based Wind Turbines

The improvement of synchronous generators (SGs) stability is one of the most important issues in power systems. To this aim, doubly fed induction generator (DFIG) can be helpful. The main purpose of this paper is to improve both transient and dynamic performance of SG by using local DFIG-based wind turbines. Firstly, a transient controller (TC) is designed in controlling block of DFIG which changes its operating mode from generator to motor regime. Secondly, two damping controllers which are named electromagnetic torque band damping controller (ETBDC) and reactive power band damping controller (RPBDC) are suggested to improve dynamic stability of SG. Each damping controller includes three feedbacks namely, SG speed changes, SG electromagnetic torque and DFIG electromagnetic torque. Moreover, genetic algorithm (GA) is used to adjust these controlling parameters. The performance of TC is examined by comparison of system transient indexes such as critical clearing time (CCT), SG accelerating energy and DFIG inertia energy with and without using the proposed TC in a two-area test network. Similarly, system dynamic performance indexes such as overshoot, settling time, eigenvalue and damping torque of SG are compared with and without using two dynamic controllers. The obtained results show the effectiveness of proposed controllers.

[1]  E. Muljadi,et al.  Effect of Variable Speed Wind Turbine Generator on Stability of a Weak Grid , 2007, IEEE Transactions on Energy Conversion.

[2]  Olimpo Anaya-Lara,et al.  Reactive power control of DFIG wind turbines for power oscillation damping under a wide range of operating conditions , 2016 .

[3]  Md Kamal Hossain,et al.  Transient Stability Augmentation of PV/DFIG/SG-Based Hybrid Power System by Nonlinear Control-Based Variable Resistive FCL , 2015, IEEE Transactions on Sustainable Energy.

[4]  Che-Hao Chang,et al.  Stability Improvement of a Two-Area Power System Connected With an Integrated Onshore and Offshore Wind Farm Using a STATCOM , 2016, IEEE Transactions on Industry Applications.

[5]  Feng Liu,et al.  Modeling of DFIG-Based Wind Turbine for Power System Transient Response Analysis in Rotor Speed Control Timescale , 2018, IEEE Transactions on Power Systems.

[6]  Miguel Ramirez,et al.  Effect of PODCs for DFIG Based Wind Farms in the Inter-area and Torsional Oscillation Damping , 2016, IEEE Latin America Transactions.

[7]  Yun Chen,et al.  Dynamic stability improvement of an integrated offshore wind and marine-current farm using a flywheel energy-storage system , 2011 .

[8]  Jingtian Bi,et al.  Damping torque analysis of power systems with DFIGs for wind power generation , 2017 .

[9]  Lingling Fan,et al.  Control of DFIG-Based Wind Generation to Improve Interarea Oscillation Damping , 2009, IEEE Transactions on Energy Conversion.

[10]  Yuan-Yih Hsu,et al.  Small‐signal stability analysis and particle swarm optimisation self‐tuning frequency control for an islanding system with DFIG wind farm , 2019, IET Generation, Transmission & Distribution.

[11]  Eduard Muljadi,et al.  Frequency Control Support of a Doubly-Fed Induction Generator Based on the Torque Limit , 2016, IEEE Transactions on Power Systems.

[12]  Mohammad-Naser Asefi,et al.  Using Adaptive Control in DFIG-based Wind Turbines to Improve the Subsynchronous Oscillations of Nearby Synchronous Generators , 2017 .

[13]  Dan Boneh,et al.  On genetic algorithms , 1995, COLT '95.

[14]  Janusz Bialek,et al.  Power System Dynamics: Stability and Control , 2008 .

[15]  Lingling Fan,et al.  Control of DFIG based wind generation to improve inter-area oscillation damping , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[16]  Issarachai Ngamroo,et al.  Hierarchical Co-Ordinated Wide Area and Local Controls of DFIG Wind Turbine and PSS for Robust Power Oscillation Damping , 2016, IEEE Transactions on Sustainable Energy.

[17]  Kit Po Wong,et al.  A Sliding Mode Based Damping Control of DFIG for Interarea Power Oscillations , 2017, IEEE Transactions on Sustainable Energy.

[18]  H.H. Zurn,et al.  Influence of the variable-speed wind generators in transient stability margin of the conventional generators integrated in electrical grids , 2004, IEEE Transactions on Energy Conversion.

[19]  Erich Hau,et al.  Wind Turbines: Fundamentals, Technologies, Application, Economics , 1999 .

[20]  Babu Narayanan,et al.  POWER SYSTEM STABILITY AND CONTROL , 2015 .

[21]  S. Mishra,et al.  Small-Signal Stability Analysis of a DFIG-Based Wind Power System Under Different Modes of Operation , 2009, IEEE Transactions on Energy Conversion.

[22]  Jingtian Bi,et al.  A Method to Examine the Impact of Grid Connection of the DFIGs on Power System Electromechanical Oscillation Modes , 2016, IEEE Transactions on Power Systems.

[23]  Istvan Erlich,et al.  Doubly Fed Induction Generator Controller Design for the Stable Operation in Weak Grids , 2015, IEEE Transactions on Sustainable Energy.

[24]  C. Y. Chung,et al.  Coordinated Damping Control Design for DFIG-Based Wind Generation Considering Power Output Variation , 2012, IEEE Transactions on Power Systems.

[25]  Olimpo Anaya-Lara,et al.  Wind Energy Generation: Modelling and Control , 2009 .

[26]  F. Mei,et al.  Modal Analysis of Grid-Connected Doubly Fed Induction Generators , 2006, IEEE Transactions on Energy Conversion.

[27]  Farrokh Aminifar,et al.  Toward Wide-Area Oscillation Control Through Doubly-Fed Induction Generator Wind Farms , 2014, IEEE Transactions on Power Systems.