An improved trap design for decoupling multinuclear RF coils

Multinuclear magnetic resonance spectroscopy and imaging require a radiofrequency probe capable of transmitting and receiving at the proton and non‐proton frequencies. To minimize coupling between probe elements tuned to different frequencies, LC (inductor‐capacitor) traps blocking current at the 1H frequency can be inserted in non‐proton elements. This work compares LC traps with LCC traps, a modified design incorporating an additional capacitor, enabling control of the trap reactance at the low frequency while maintaining 1H blocking.

[1]  P. Allen,et al.  In vivo NMR spectroscopy. , 1990, Basic life sciences.

[2]  Oliver Bieri,et al.  23Na MR imaging at 7 T after knee matrix-associated autologous chondrocyte transplantation preliminary results. , 2010, Radiology.

[3]  Mary P. McDougall,et al.  An insertable P-31 RF coil for dual-frequency magnetic resonance imaging & spectroscopy , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  C J Hardy,et al.  Proton‐decoupled, overhauser‐enhanced, spatially localized carbon‐13 spectroscopy in humans , 1989, Magnetic resonance in medicine.

[5]  B Chance,et al.  Noninvasive, nondestructive approaches to cell bioenergetics. , 1980, Proceedings of the National Academy of Sciences of the United States of America.

[6]  Paul A Bottomley,et al.  Noise figure limits for circular loop MR coils , 2009, Magnetic resonance in medicine.

[7]  S Nioka,et al.  Multiple controls of oxidative metabolism in living tissues as studied by phosphorus magnetic resonance. , 1986, Proceedings of the National Academy of Sciences of the United States of America.

[8]  Christian Beaulieu,et al.  Sodium imaging intensity increases with time after human ischemic stroke , 2009, Annals of neurology.

[9]  Mary P. McDougall,et al.  Trap design for insertable second-nuclei radiofrequency coils for magnetic resonance imaging and spectroscopy , 2009 .

[10]  Evaluation of extra‐ and intracellular apparent diffusion coefficient of sodium in rat skeletal muscle: Effects of prolonged ischemia , 2008, Magnetic resonance in medicine.

[11]  N. Smith 31P spectroscopy in human calf muscle at 7 tesla using a balanced double-quadrature proton- phosphorus RF coil , 2009 .

[12]  M Alecci,et al.  Practical design of a 4 Tesla double-tuned RF surface coil for interleaved 1H and 23Na MRI of rat brain. , 2006, Journal of magnetic resonance.

[13]  G K Radda,et al.  Quantitative interpretation of bioenergetic data from 31P and 1H magnetic resonance spectroscopic studies of skeletal muscle: an analytical review. , 1994, Magnetic resonance quarterly.

[14]  Vanhamme,et al.  Improved method for accurate and efficient quantification of MRS data with use of prior knowledge , 1997, Journal of magnetic resonance.

[15]  Rolf Gruetter,et al.  Localized in vivo 13C NMR spectroscopy of the brain , 2003, NMR in biomedicine.

[16]  Ewald Moser,et al.  Comparing localized and nonlocalized dynamic 31P magnetic resonance spectroscopy in exercising muscle at 7T , 2012, Magnetic resonance in medicine.

[17]  Luc Darrasse,et al.  Quick measurement of NMR‐coil sensitivity with a dual‐loop probe , 1993 .

[18]  R G Shulman,et al.  Quantitation of hepatic glycogenolysis and gluconeogenesis in fasting humans with 13C NMR. , 1991, Science.

[19]  D. Graveron-Demilly,et al.  Java-based graphical user interface for the MRUI quantitation package , 2001, Magnetic Resonance Materials in Physics, Biology and Medicine.

[20]  G. Adriany,et al.  A half-volume coil for efficient proton decoupling in humans at 4 tesla. , 1997, Journal of magnetic resonance.

[21]  Robin A. de Graaf In vivo NMR spectroscopy , 1998 .

[22]  J. Fitzsimmons,et al.  Double resonant quadrature birdcage , 1993, Magnetic resonance in medicine.

[23]  M. Schnall,et al.  The application of overcoupled tank circuits to NMR probe design , 1986 .

[24]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.