New aerosol sampler with low wind sensitivity and good filter collection uniformity

Abstract The overall sampling efficiency of many aerosol samplers is sensitive to wind velocity and direction. In addition, most samplers have internal losses due to gravitational settling, electrostatic interactions, and internal turbulence. A new sampling inlet has been designed to reduce these problems. The flow patterns over the new prototype sampler were visualized in a horizontal wind tunnel. Visualization of the streamlines over the new sampler and limiting-streamline quantitative analysis showed negligible turbulence effects due to the inlet's geometry. The overall sampling efficiency of the prototype sampler was compared to that of a 25 mm closed-face cassette. Uranine was used as the challenge aerosol with particle physical diameters of 13.5, 20 and 30 μm. The wind velocity ranged from 100 to 300 cm s −1 . Evaluation of the data showed the new sampler to be less significantly affected by wind direction and magnitude. The particle distribution observed on the sampler's filter was found to be reasonably uniform, an advantage for several types of analyses.

[1]  K. Willeke,et al.  A general equation for aerosol aspiration by thin-walled sampling probes in calm and moving air , 1993 .

[2]  K. Willeke,et al.  Sampling and interpretation errors in aerosol monitoring. , 1990, American Industrial Hygiene Association journal.

[3]  P. Baron,et al.  Electrostatic effects in asbestos sampling. I: Experimental measurements. , 1990, American Industrial Hygiene Association journal.

[4]  J H Vincent,et al.  A new static sampler for airborne total dust in workplaces. , 1985, American Industrial Hygiene Association journal.

[5]  D Mark The use of dust-collecting cassettes in dust samplers. , 1990, The Annals of occupational hygiene.

[6]  S C Soderholm,et al.  Aerosol sampling efficiency of 37 mm filter cassettes. , 1986, American Industrial Hygiene Association journal.

[7]  P. A. Tufto,et al.  Dependence of particulate sampling efficiency on inlet orientation and flow velocities , 1982 .

[8]  James H. Vincent,et al.  Aerosol sampling : science and practice , 1989 .

[9]  Sarah J. Dunnett,et al.  An Empirical Model for the Aspiration Efficiencies of Blunt Aerosol Samplers Orientated at an Angle to the Oncoming Flow , 1988 .

[10]  Benjamin Y. H. Liu,et al.  Generation of monodisperse aerosol standards , 1973 .

[11]  R A Botham,et al.  Field comparison of personal samplers for inhalable dust. , 1990, The Annals of occupational hygiene.

[12]  K. Willeke,et al.  Aspiration Efficiency: Unified Model for All Forward Sampling Angles , 1990 .

[13]  K. Okazaki,et al.  Isoaxial Aerosol Sampling: Nondimensional Representation of Overall Sampling Efficiency , 1987 .

[14]  J H Vincent,et al.  A new personal sampler for airborne total dust in workplaces. , 1986, The Annals of occupational hygiene.

[15]  J H Vincent,et al.  The development of a test system for investigating the performances of personal aerosol samplers under actual workplace conditions. , 1991, American Industrial Hygiene Association journal.

[16]  Sidney C. Soderholm,et al.  Proposal for Converting “Total” Dust Limits to Inhalable and Thoracic Dust Limits , 1993 .

[17]  K. Okazaki,et al.  Influence of turbulence on aerosol sampling efficiency , 1988 .

[18]  H J Beaulieu,et al.  A comparison of aerosol sampling techniques: "open" versus "closed-face" filter cassettes. , 1980, American Industrial Hygiene Association journal.

[19]  K. Willeke,et al.  Overall efficiency of tubular inlets sampling at 0-90 degrees from horizontal aerosol flows , 1990 .

[20]  K. Okazaki,et al.  Non-isoaxial aerosol sampling: mechanisms controlling the overall sampling efficiency , 1987 .

[21]  R. Sextro,et al.  Deposition of Tobacco Smoke Particles in a Low Ventilation Room , 1994 .

[22]  Kenneth L. Rubow,et al.  Generation of Large, Solid, Monodisperse Calibration Aerosols , 1988 .

[23]  K. T. Whitby,et al.  Polystyrene aerosols—electrical charge and residue size distribution , 1968 .

[24]  T. Ogden,et al.  An inhalable-dust sampler, for measuring the hazard from total airborne particulate. , 1978, The Annals of occupational hygiene.

[25]  L. M. Levin,et al.  Techniques for collection of representative aerosol samples , 1974 .

[26]  S. Badzioch,et al.  Collection of gas-borne dust particles by means of an aspirated sampling nozzle , 1959 .

[27]  L. M. Levin,et al.  Investigation of aerosol aspiration by photographing particle tracks under flash illumination , 1972 .

[28]  R Kucharski A personal dust sampler simulating variable human lung function. , 1980, British journal of industrial medicine.