An approach for controlled reclosing of shunt compensated transmission lines

An approach for controlled reclosing of transmission lines with shunt reactive compensation is proposed here to reduce switching surge overvoltages. It consists on applying Karrenbauer's transformation as a matrix operator for the analysis of voltage signals required to control switching operations. The procedure also determines the arc extinction time for single and double-phase to ground faults which may avoid unsuccessful reclosing. A device to control the line reclosing was implemented and evaluated through real time simulations. An offline version was implemented for parametric and sensitivity analysis through the EMTP using actual parameters from the Brazilian Power System Grid. Several field oscillographic data, obtained from Brazilian power transmission lines with different transposition schemes were used to validate the proposed approach and the results attest its efficiency.

[1]  B.A. Souza,et al.  Mitigation of switching overvoltages in transmission lines via controlled switching , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[2]  Aniruddha M. Gole,et al.  Implementation and Performance Evaluation of a Reclosing Method for Shunt Reactor-Compensated Transmission Lines , 2011 .

[3]  H.E. Konkel,et al.  Limiting switching surge overvoltages with conventional power circuit breakers , 1977, IEEE Transactions on Power Apparatus and Systems.

[4]  Peter Schegner,et al.  An algorithm for the three-pole controlled auto-reclosing of shunt compensated transmission lines with an optimization for the second and third pole , 2004 .

[5]  H. Ito Controlled switching technologies, state-of-the-art , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[6]  M. S. Sachdev,et al.  Phasor estimation technique to reduce the impact of coupling capacitor voltage transformer transients , 2008 .

[7]  D. F. Peelo,et al.  Controlled closing on shunt reactor compensated transmission lines. I. Closing control device development , 1997 .

[8]  M. Sanaye-Pasand,et al.  Improving Controlled Closing to Reduce Transients in HV Transmission Lines and Circuit Breakers , 2013, IEEE Transactions on Power Delivery.

[9]  P. Bastard,et al.  On controlled switching of high voltage unloaded transmission lines , 2002 .

[10]  Mohammad E. Khodayar,et al.  Limitation of transmission line switching overvoltages using switchsync relays , 2005 .

[11]  F. B. Costa,et al.  Real-time detection of fault-induced transients in transmission lines , 2010 .

[12]  D. F. Peelo,et al.  Controlled closing on shunt reactor compensated transmission lines. II. Application of closing control device for high-speed autoreclosing on BC Hydro 500 kV transmission line , 1997 .

[13]  D. Tziouvaras,et al.  Controlled Switching of HVAC Circuit Breakers: Application Examples and Benefits , 2008, 2008 61st Annual Conference for Protective Relay Engineers.